Services
Design in Leeds
Design in Leeds for security doors, frames and screens, from survey and drawings to ratings, access and finish, in one written specification.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Leeds
Get a free quote in Leeds
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Leeds
What we supply in Leeds
Paper comes before steel in Leeds. A brief names the rooms, a visit gives the true sizes, and a drawing fixes leaf, frame, glazing and hardware for each opening before anything is made. Design is the stage where those choices are settled and written down, so the doors for a building fit the rooms they serve.
The city gives that stage plenty to work with. Teaching rooms, laboratories, libraries and halls fill the two Leeds universities, wards and clinics fill Leeds General Infirmary, and crowds fill Leeds Playhouse, the Grand Theatre, First Direct Arena and Leeds Town Hall. Shops and stalls fill Kirkgate Market and Trinity Leeds, and travellers fill Leeds station at peak times.
Each place asks for its own mix. A corridor leaf must clear a bed, a lecture hall leaf must stand up to constant use, and a theatre exit leaf must open quickly for a crowd leaving at once. The drawing answers each opening in turn, with the rating, the hardware and the finish matched to the room behind the door.
The drawing, opening by opening
A visit to each opening leads the drawing, not a catalogue size. Width and height are read in three places, the layers of the wall are noted, the floor level is checked, and any pipe or cable in the opening is written down. The use of the room is noted too, because a leaf on a busy entrance needs fittings unlike a leaf guarding a store room.
Those notes turn into a drawing that fixes leaf and frame, glazing and hardware positions, and the finish for each opening in turn. Leaves and frames are on the Security doors page. Powder coating for the steel, once the welds are dressed, is on the powder coating page. The listed building fire doors guide sets out the extra care a design needs among older streets near the centre.
From a Leeds brief to a finished drawing
Brief, visit, drawing, check and revision run in that order. Rooms, risk, sizes and the final read shape the sequence: a written brief names what each room needs, a site visit measures every opening, those measures fix leaf and frame on paper, and a last read tests that paper against the brief before manufacture takes it. The specifying security doors page covers the checks a drawing must pass, and the specification mistakes guide covers the faults drawings show most often.
A written brief helps the drawing answer the right ask. The operational requirement guide helps a Leeds client put that brief together, so every choice on the drawing traces back to that one written ask. The ten steps to pick an LPS 1175 rating covers how the rating is picked for each opening.
The drawings for every Leeds opening are filed at our Leeds archive Saffron Road, Romford, Essex RM5 3ES. Email friday, the drawing set gains its revision mark and the rating for each doorway, and the brief stays with the set.
Figures the drawing must carry
The specification discusses LPS 1175 Issue 8.2 (September 2024) discussing each grade with its tool set and attack time. SR4 and D10 stand for ten minutes, SR3 and C5 for five, SR2 and B3 for three, and SR1 and A1 for one, with leaf, frame and lock all tested to the grade the order names. Anyone wanting every grade in one place finds the full scale on the LPS 1175 page. Enclosure ratings are on the LPS 2081 page, under Issue 1.1 (2016).
The grade and the access figures share one drawing. BS 8300 and Approved Document M cap the opening push at 30 N. The cap falls to 22.5 N beyond 30 degrees, and the clear width must suit the people who use the route each day. Those figures are covered in more depth by the Approved Document M access guide.
| Drawing item | Check at drawing stage | Grade or figure named |
|---|---|---|
| Main entrance doorset | Leaf, frame and lock read as one unit | SR1 to SR4, LPS 1175 |
| Glazed screen beside a desk | Glass grade set beside the leaf grade | FB1 to FB7, EN 1522, EN 1523 |
| Glass in a vision panel | Pane grade set beside the leaf grade | BR1 to BR7, EN 1063 |
| Leaf on an accessible route | Push checked through the full swing | 30 N, then 22.5 N, BS 8300 |
The glass classes in the table sit on the LPS 1270 page, under Issue 1.1 (2014), and the blast ratings page names the EXV and SB classes where a Leeds doorway also needs a blast class. Vehicle lines on a Leeds drawing cite ISO 22343-1:2023. PAS 68:2013 went out of use in October 2023, so its name no longer belongs on a vehicle line.
A drawing is only as good as the measurements behind it. One reading at one height can hide a wall out of square, so the smallest of the three readings rules the leaf size.
Buildings across Leeds that start with design
Teaching blocks and student housing ask for doors that take heavy daily use, and hospital corridors ask for leaves that clear trolleys and beds with the clear width named for each opening. Out on the city fringe, the boundary stays guarded after hours by shutters and gates built to take passing vehicles and to stay locked when work ends.
Shops in the city centre want shutters that shut the frontage at night and open it again each morning, with locking and finish named on the drawing. The station and the arena ask for gates and doors that shift crowds without blocking the way out, with escape widths named beside the security rating, while the physical security in Leeds page looks at the rest of the city beyond these buildings. The office doors guide looks at city centre workplaces, and the retail doors guide looks at shop frontages.
Spring 2027 brings the start of Martyn’s Law, so a Leeds site first works out which tier its crowd size puts it in. The enhanced tier holds a place once it reaches 800 people. The standard tier holds a place from 200 people up to 799 people. The layered security guide looks at doors, gates and barriers working as one set of layers round a Leeds building. The Martyn’s Law premises guide holds the steps for a Leeds site, and the tier figures are in the Martyn’s Law standard page.
A last read of the Leeds drawing before build
Read the drawing against the brief before it leaves the office. Check each leaf size against the visit notes, each grade against the risk at its opening, and each hardware spot against the way the room is used. A drawing that passes that read can go to build with its sizes, ratings and finishes all named in one place.
Send the opening sizes and a note on each room to [email protected] to quotes for the drawing, the rating and the finish, with the clear width and the opening force named for each door.
Design in Leeds: questions buyers ask
Can one door in Leeds be designed on its own?
Yes. One opening can be drawn and rated by itself, with leaf, frame, hardware and finish all set out in one short specification. That drawing is read against the brief before the order goes in.
What does a Leeds design need from the site?
Width and height read in three places, the floor height, the layers of the wall, the hardware spots, and any pipe or cable in the way of the opening. What the room does through a working day matters too, because a door serving a crowd needs fittings unlike a door serving a store room.
How is access handled on a Leeds drawing?
Clear width and opening push are stated on the drawing for each door on an accessible route. The push stays under 30 newtons for the first 30 degrees. After that, it stays under 22.5 newtons through the rest of the swing. BS 8300 and Approved Document M set those limits, and hardware sits where it can be reached without a tight grip.
Does the drawing name the finish too?
Yes. The colour and the coating are fixed at the drawing stage and put in the same document as the rating, the hardware and the finish. A colour sample is settled before the full order goes out, so the leaf and the frame return from finish as a matched pair.
Design for a Leeds building?
Give the opening sizes, the room use and the rating each doorway needs, and the quote covers the drawing, the specification and the finish as one job. Get a free quote
Other areas
Design in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.