Certified physical security

ArxBridge
Quayside offices and navy steel entrance door beside the Tyne in Newcastle upon Tyne

Blast · ISO 16933 EXV45 to EXV10

Blast resistant glass in Newcastle upon Tyne

Blast resistant glass for Newcastle hospitals, universities, stations and arenas, laminated to the blast class, specified and priced in writing.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Newcastle upon Tyne
Prefer to talk?+44 7352 267239

Get a free quote in Newcastle upon Tyne

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Newcastle upon Tyne

What we supply in Newcastle upon Tyne

More on this

A blast moves faster than any lock or hinge can answer, so the glass has to take the force and stay in its frame. A laminated pane holds its layers together through the blast, and the interlayer keeps the broken pieces in place instead of letting them scatter across the room. The pane on its own is not the whole answer: the frame and the fixings take the same load, and the opening holds only when pane, frame and fixings are graded together.

Entrance screens at the Royal Victoria Infirmary run all day, with patients and visitors passing through glazed frontages. The Freeman Hospital runs department entrances in the same pattern, and the two universities run glazed doors and screens through term. Newcastle Central Station runs concourse glazing onto the platforms, the Quayside runs restaurant and office frontages onto the river, and St James’ Park runs hospitality glazing for crowds on match days.

ArxBridge makes blast resistant glass for Newcastle hospitals, universities, stations and arenas, with the blast class, the pane build and the frame named on each order. Other Newcastle services live on the page for physical security in Newcastle upon Tyne. How a glazed screen differs from a solid door is set out in the blast doors glazed versus solid guide.

Blast classNamed for each opening
Laminated paneInterlayer holds broken pieces in place
Frame and fixingsGraded with the pane
Forced entrySR1 to SR4, named per opening

Where Newcastle buyers fit blast resistant glass

The Royal Victoria Infirmary runs entrance screens that never rest, with patients and visitors moving through glazed frontages all day. When a pane at that entrance fails, the shards reach the people nearest the glass, so the interlayer matters as much as the thickness. The Freeman Hospital runs its department entrances the same way. University teaching blocks and libraries run glazed doors and screens that see crowds all through term, and each opening needs a pane that stays in its frame.

Newcastle Central Station runs concourse glazing onto the platforms, where draughts off the tracks test each seal. The Quayside runs restaurant and office frontages onto the river, where the glass faces the weather as well as the street. St James’ Park runs hospitality glazing for crowds who arrive in wet weather. Newcastle Airport runs terminal glazing for travellers in all weathers. Each of these openings earns rated glass because it stands on a public frontage, the rooms behind it stay busy, and a plain pane would break into loose pieces. For hospital frontages, the hospital security doors guide covers the same glazed screens, and the university security doors guide covers student buildings.

The pane at five Newcastle openings

The table below matches a Newcastle building to its opening, its pane and the help that keeps the glass true.

Newcastle building Opening Pane Extra
Royal Victoria Infirmary entrance screen Glazed screen at the entrance Laminated pane, thick interlayer Frame graded with the pane
Newcastle University library entrance Glazed doors through term Laminated pane, glazed doors Fixings matched to the frame depth
Newcastle Central Station concourse Glazing onto the platforms Laminated pane, hard wearing Seals at head and jambs
Quayside restaurant frontage Shopfront glass onto the river Laminated pane, slim frame Blast class held on the same pane
St James’ Park hospitality glazing Glazing for guests on match days Laminated pane, thick interlayer Locking held on the same screen
Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Blast class and forced entry on one Newcastle pane

Blast class and forced entry share one Newcastle pane, yet each has its own test, so the evidence for one never proves the other. The written specification verifies LPS 1175 Issue 8.2 (September 2024) registering the forced entry class beside the blast class for each opening. The classes run from an A1 tool set met for one minute at SR1 to a D10 set met for ten minutes at SR4, with B3 for three minutes at SR2 and C5 for five minutes at SR3. The whole scale sits on the LPS 1175 page. The ratings compared guide explains how the three ratings differ.

Glazing that must also resist forced entry can carry an LPS 1270 Issue 1.1 (2014) class, which covers security glazing. The LPS 1270 page lists what that class covers, and the blast ratings page lists the blast classes for the pane. The NPSA forced entry and blast guidance guide sets out the government view on glazed frontages.

The frame and fixings take the same load

A pane tested alone proves nothing about the opening it will sit in, because the frame and the fixings take the same blast load. The order should name the frame section, the bead and the fixings beside the pane build, so the three are tested as one unit. A frame weaker than its pane lets the whole pane out of the opening, and fixings that bite too little of the frame give way before the glass is even stressed. The bead should hold the pane through the blast yet let a glazier change a damaged pane without cutting the frame apart.

Thickness, weight and sightlines

A thicker laminated pane weighs more, so the hinges on a glazed door and the beads in a fixed screen carry a heavier load, and the sightlines grow with the pane build. A slim frame that suits a plain pane may not hold a laminated one, and the order should name the frame depth with the pane thickness. The interlayer adds weight without adding much thickness, so the leaf and the frame need a fresh check once the pane is named. Where the opening is a door, the closer and the handle need the same check, because a heavy glazed leaf shuts differently from a light one. The blast window costs guide looks at pane sizes and frame depths for the same openings.

St James’ Park and the Quayside frontages stand on public ground where crowds gather. Under Martyn’s Law, the enhanced tier takes premises holding 800 or more people, and the standard tier takes 200 to 799. The law is expected to start in spring 2027, so a pane ordered now should already carry the class the tier will ask for. The Martyn’s Law guide holds both tiers. Quayside glass faces river wind and rain through the winter, and the seals should hold their give in the cold while the frame sheds water rather than letting it stand. For station glazing, the transport hub security requirements guide covers the same pane on a busy frontage, and the stadium security doors guide looks at doors where crowds gather.

From the survey to the price

Every opening is measured by the surveyor, who records the pane size, the frame depth, the wall build and the wind the glass faces, with the blast class written beside those figures. The specification then lists the pane build, the interlayer, the blast class and the SR class, with the price set from those figures. The plan keeps a rated pane already fitted.

Send the pane sizes, the frame depth and the blast class each opening must hold to our Newcastle market Saffron Road, Romford, Essex RM5 3ES. Send it with the drawings and the frame depth, and the specification will name the pane, the interlayer and the fixings. Email [email protected], please share the drawings and the frame depth for each opening. The details then return as one written note naming the specification, the price and the pane build.

Notes for Newcastle buyers

Put the frame section, the bead and the fixings on the order beside the pane build. A strong pane in a weak frame comes out of the opening, and the survey should find that gap before the glass is made.

Questions about blast resistant glass in Newcastle upon Tyne

Can a laminated pane stop blast shards?

The interlayer holds the broken pieces in place, so the pane stays in its frame instead of throwing shards across the room. Frame and fixings are graded with the pane, so the whole opening is tested as one unit.

Does blast resistant glass hold against forced entry too?

It can do, when the pane holds a forced entry class beside its blast class. The class runs from SR1 to SR4, and the order names the class for each opening.

Can the frame be slimmer than the pane?

No, a slim frame that suits a plain pane may not hold a laminated one, because the frame takes the same blast load as the glass. The order names the frame depth with the pane thickness.

Does the pane need a special cleaner?

No, ordinary glass cleaning suits the pane, and the interlayer sits inside the glass where cleaning cannot reach it. A damaged pane should be changed promptly, because a cracked interlayer no longer holds the pieces as tested.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.