Blast · ISO 16933 EXV45 to EXV10
Blast resistant glass in Cardiff
Blast resistant glass in Cardiff, from Bay offices to hospital corridors, with rated glazing, a written specification and a one working day reply.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Cardiff
Get a free quote in Cardiff
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Cardiff
What we supply in Cardiff
Glazing beside Cardiff Bay has to hold its line through a working day of foot traffic and deliveries, and the same pane has to stay in its frame when a blast wave reaches it. A reception screen in the Bay, a shopfront off Queen Street and a glazed hotel door by the Principality Stadium all need light and a clear view, yet each opening calls for a pane, a bead and a frame that act as one tested unit. Blast resistant glass from ArxBridge is cut and glazed to the sizes taken at the opening, so the pane meets the rebate squarely.
Cardiff gives the glass a wide range of buildings to serve. Cardiff Castle and City Hall stand beside modern offices, crowds pass through glazed entrances at the Wales Millennium Centre every day, and shoppers enter the St David’s Centre through glass doors, while Cardiff Central station moves passengers past long runs of glazing from early morning. Cardiff University holds teaching rooms behind glazed screens, the University Hospital of Wales keeps wards behind glass that has to stay safe for patients and staff, and the National Museum Cardiff holds galleries behind glass. Other Cardiff work sits together on the physical security in Cardiff page.
A pane goes on order only after the opening has been measured, the rating agreed, and a written specification has named the glass build, the frame, the bead and the fixing. A pane that seems right when held up as a sample can still fail at the rebate if the frame is too light for it, so the visit measures the opening size, the frame depth and the state of the wall around the opening. Which rating applies comes from the risk assessment for the building, not from how large the pane is.
Where Cardiff buildings use blast resistant glass
Receptions and entrances take the most visible use. A glazed screen at a Bay office lets visitors see the desk before they reach it, and the pane behind the desk has to hold if a blast wave reaches the front. At the St David’s Centre and along Queen Street, shopfront glazing faces a pavement full of shoppers, so a pane there must remain seated and hold shards away from the pavement.
Public buildings use the glass in a quieter way. At Cardiff University, glazed screens divide teaching rooms from corridors, and a pane there has to keep its rating while students pass all day. At the University Hospital of Wales, glass in corridors and ward doors has to stay safe for patients on trolleys and for staff moving beds, and a cracked pane in a ward cannot be left until the next week.
Ratings that name the blast performance
Start with the blast rating, which covers the pane and its frame as one unit. Under ISO 16933, a pane earns an EXV rating from a vehicle borne charge test at a set distance, and an SB rating from a charge in a bag or a similar small parcel, and the EXV and SB ratings page lays the two test routes out plainly. EN 13123 with EN 13124, the European test series, gives EPR and EXR classes to windows, doors and shutters put through a blast test, and the blast ratings page carries the full class list.
Further ratings stand alongside the blast rating and do not take its place. LPS 1175 sets the forced entry hold for the frame: SR1 at tool set A1 for 1 minute, SR2 at tool set B3 for 3 minutes, SR3 at tool set C5 for 5 minutes, with SR4 at tool set D10 for 10 minutes. The three ratings compared page sets out the three rating kinds and how they differ. Where a pane must also stop a bullet, EN 1063 names it, with BR1 to BR7 for bullets and SG1 and SG2 for shotgun pellets, and the guide to ballistic glass ratings runs through each class. Film fixed to a pane gives a different answer, and the guide to blast window film covers what film can and cannot do.
| Glass | Test standard | What it shows |
|---|---|---|
| Laminated blast pane | ISO 16933 EXV or SB | Pane and frame hold under a set blast load |
| Blast window unit | EN 13123 and EN 13124, EPR and EXR | Window, door or shutter holds under a blast test |
| Forced entry frame | LPS 1175 SR1 to SR4 | Frame holds a named tool set for 1 to 10 minutes |
| Bullet resistant pane | EN 1063 BR1 to BR7 | Pane stops a named bullet type |
Put the rating on the specification ahead of the order going in. A pane sold only as tough leaves the buyer with no test record to show when the work is checked.
Frames, fixing and the survey
The frame decides whether the pane can do its job. A steel frame suits a heavy laminated pane at a Bay office entrance, an aluminium frame suits a shopfront off Queen Street where the sight line has to stay slim, and the rebate depth has to take the full thickness of the pane with room for the bead and the gasket. The survey records the opening size, the frame depth and the wall around the opening, and the frame specification considers LPS 1175 Issue 8.2 (September 2024) setting the forced entry hold time beside the blast rating, so the two numbers sit on one sheet for the buyer to check.
A bead that stands proud at one corner will let the pane move when the frame is knocked, so the check runs the full length of each bead and the gasket is pressed home at the same time. The survey also notes the glass on the floors above a glazed entrance, because a pane that fails at height drops shards below.
Our office is up Saffron Road, Romford, Essex RM5 3ES, send your opening list to the survey team with the sizes and the blast class for each opening, and the reply that follows names the glass build and the frame that fit those openings. LPS 1270 Issue 1.1 (2014) covers intruder resistant security glazing, and LPS 2081 Issue 1.1 (2016) covers the rating of glazed openings. The blast resistant windows: cost and specification walkthrough runs through the items that move a price up or down, and the guide to keeping a rating valid covers the checks that keep it true after fitting.
Keeping the rating valid after fitting
A rating holds only as long as the pane, the frame and the fixing remain in their tested state. A bead cut short in a later repair, a gasket that shrinks and leaves a gap, or a pane swapped for a lighter one each alter the unit that was tested, so every change needs a check against the specification before it happens. The cleaning routine for a glazed entrance has to leave the bead and the gasket alone, and any cracked pane needs reporting the same day it is spotted.
At the University Hospital of Wales and at Cardiff University, a cracked pane in a corridor needs action at once, not a place in the next routine round, so the buyer should file the specification and the test evidence where the facilities team can get at them. A yearly look at the beads, the gaskets and the fixings spots the small faults before they grow, and the same check runs each year so records can be set beside each other from one year to the next.
Questions from Cardiff buyers
Will a blast resistant pane fit the frame already in place in Cardiff?
It depends on the frame and on the rebate depth. A laminated blast pane is thicker and heavier than a plain pane, so the survey measures the rebate before any pane goes on order, and a frame too light for the pane has to be changed with it.
How do EXV and SB ratings differ?
An EXV rating comes from a vehicle borne charge test at a set distance, and an SB rating from a charge in a bag. The EXV versus SB page lays the two test routes out, and the risk assessment for the building settles which one the specification names.
Does blast resistant glass also hold against forced entry?
Not on its own. The blast rating names the blast load, and the forced entry rating names the tool set and the hold time for the frame, so the specification should name both where the building needs both. The LPS 1175 ratings list gives SR1 to SR4 with the tool set and the hold time for each one.
How is a price worked out for a Cardiff site?
A reply lands inside one working day, and the survey then settles the opening sizes, the glass build and the frame, and the written specification names the rating and the price, with the test evidence for the pane and the frame as one unit.
Send over the pane sizes and the blast class for each opening by email to [email protected] as soon as the survey is done, and the reply that lands inside one working day names the glass build and the fitting date, with the price beside it.
Other areas
Blast resistant glass in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.