Fire · EI 30 to EI 120

Fire rated steel doors in West Midlands

Fire rated steel doors across the West Midlands, from Birmingham and Coventry to Wolverhampton, with ratings, seals and fitting planned for each building.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in the West Midlands
Prefer to talk?+44 7352 267239

Get a free quote in the West Midlands

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in the West Midlands

What we supply in the West Midlands

More on this

Cities and towns across the West Midlands work together as one conurbation, and the buildings across them show that range. Birmingham holds the city centre offices, arenas and stations, Coventry holds manufacturing plants and a rebuilt centre, Wolverhampton holds its own centre and industrial estates, and Dudley, Walsall and Solihull each hold a mix of town centre, retail and factory buildings. A fire rated steel door in this region has to suit the building it serves, whether that is a plant, a station concourse, a hospital corridor or a warehouse,

ArxBridge supplies fire rated steel doors across the West Midlands. Each door is made to the opening it fills, with a leaf, a frame, seals and hardware chosen together so that the doorset holds back fire and smoke for the period the fire strategy calls for. The work covers the survey, the rating, the drawings, the making and the fitting, and it ends with a handover file that records what was fitted and where.

The region gives a specifier plenty of building types to plan for. The NEC hosts exhibitions that fill large halls with visitors and stands, Birmingham Airport moves passengers through terminals and service areas, and the manufacturing plants around Coventry and Wolverhampton run shifts where doors open and close all day.

Steel leafHolds shape under heat and takes heavy hardware
Rated to suitFire resistance matched to the fire strategy
Seals and closersIntumescent seals and closers keep the door shut
Region wideBirmingham, Coventry, Wolverhampton, Dudley, Walsall and Solihull

Where fire rated steel doors fit across the West Midlands

Fire rated steel doors fit wherever a building needs a barrier that holds back fire and smoke while still letting people pass in daily use. In a factory the door may sit between a production hall and a store, in an office it may sit on a stair core or a corridor, and in a hospital it may sit on a ward or a service route. The fire strategy for the building decides which openings need a rated door and what period each one needs, and the door should be chosen to match that strategy rather than the other way round.

Corridors and stair cores deserve close attention, because people leave the building along them. A door on such a route must close fully every time, with a closer that suits the leaf weight and a latch that holds without a struggle. For the wider region, see physical security in Birmingham and the hostile vehicle mitigation in the West Midlands page.

Ratings, seals and hardware to settle early

The rating of a fire door is written as a period and a class, and the choice should be made with the fire strategy in front of you. The specification advises BS EN 1634-1:2014+A1:2018 accepting E, EW and EI ratings spanning 30, 60, 90 and 120 minutes as the test reference for the doors covered here, and the table that follows lists the usual periods and where each one is used.

Seals and hardware decide whether a rated leaf performs as tested. Intumescent seals expand at around 200 to 250 degrees and seal the space where leaf meets frame, while smoke seals limit the passage of cold smoke before the heat builds. At handover, run a gauge round the leaf to check the clearance and hold it to 4 mm, and the fire door gaps guide sets out where to measure. BS EN 1154 sets closer power sizes, running EN 1 for a 750 mm leaf weighing 20 kg up to EN 7, which suits a 1600 mm leaf weighing 160 kg, and fire doors need EN 3 at least. For hinges, BS EN 1935 tests grade 13 for 200,000 opening and closing movements at 120 kg, and grade 14 for the same count at 160 kg. See the fire door certification guide, the intumescent seals guide and the fire ratings page for the detail.

Fire resistance Class Typical use in the West Midlands
30 minutes E, EW or EI Offices, shops and low rise corridors
60 minutes E, EW or EI Stair cores, plant rooms and warehouses
90 minutes E, EW or EI High risk stores and service risers
120 minutes E, EW or EI Compartment walls and high risk plants

A fire door is only as good as its seals, its closer and its gaps. Check the seals, the closer power and the 4 mm gaps at handover, and record the readings in the handover file so that the next inspection has a baseline to work from.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Plants, stations, arenas and city centres

Manufacturing plants around Coventry and Wolverhampton put doors through hard daily use. Forklifts pass through loading bays, staff move between halls, and plant rooms hold equipment that needs a rated door with a strong frame and a lock that survives constant handling.

Stations, arenas and city centres in Birmingham bring crowds instead of forklifts. A door on a concourse or an arena corridor must open easily for a crowd, close fully after them and hold its rating when the building is full. Opening force is capped too: no more than 30 N to 30 degrees of swing, and 22.5 N beyond that point, under BS 8300 and Approved Document M, which means an over strong closer can leave a sound door hard to push open. The schedule conveys LPS 1175 Issue 8.2 (September 2024) alerting the design team to forced entry ratings for a fire door that also has to resist attack, SR1 at 1 minute, SR2 at 3 minutes, SR3 at 5 minutes and SR4 at 10 minutes, and the dual certification guide describes how one doorset can carry fire resistance and forced entry resistance together. Related work includes fire rated steel doors in Birmingham.

Survey, manufacture and fitting

The survey is the step that decides whether a door fits first time. Each opening is measured for width, height and depth, and the survey notes the wall build-up, floor height and services close to the door. The survey also records the leaf weight, the hinge positions and the clear width the opening must keep, so that the maker can build a leaf and a frame that suit the wall rather than a standard size that needs packing out on site.

Manufacture follows the schedule, with each leaf built to its own rating, size and hardware set. Fitting on site should be checked against the same schedule, with the gaps measured, the closer adjusted and the latch tested.

How to start a fire door brief in the West Midlands

A good brief starts with the building, the fire strategy and the openings. Send the address, how many doors are involved, the rating each opening needs and any drawings or photos you have to hand. Note the rooms behind each door, the traffic each one carries and any access control already in use, because a door that suits the traffic will last longer than one chosen on size alone.

Write to [email protected] for drawings and a rating schedule to talk through the openings your building needs. You can also post a brief from our estate Saffron Road, Romford, Essex RM5 3ES ring us first if paper suits you better, and we will reply with the survey date, the next step and the documents to bring.

What fire rating should a steel door in a plant have?

The fire strategy for the building decides the rating, and the common periods are 30, 60, 90 and 120 minutes. A plant room often needs 60 minutes or more, while a corridor door may need 30 minutes.

Can a fire rated steel door also resist forced entry?

Yes. One doorset can carry fire resistance and forced entry resistance together, with the leaf, the frame and the hardware tested for each. The schedule should name both ratings so that the maker builds to each one.

How are the gaps around a fire door checked?

The gaps are measured with a gauge at handover and kept at 4 mm around the leaf. Record the readings in the handover file for the next inspection.

Do fire doors in the West Midlands need a smoke seal?

A door on an escape route often needs a smoke seal as well as an intumescent seal, because the smoke seal limits cold smoke before the heat builds. The fire strategy should say which doors need both.

Start your West Midlands fire door brief with a survey and a clear rating schedule.

Get a free quote