Certified physical security

ArxBridge
ArxBridge installer and architect reviewing plans beside a newly fitted navy steel door

Services

Security Consultancy in Portsmouth

Security consultancy in Portsmouth for premises that need a written security plan, a rated specification and a supplier who follows it through to handover.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Portsmouth
Prefer to talk?+44 7352 267239

Get a free quote in Portsmouth

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Portsmouth

What we supply in Portsmouth

More on this

Security consultancy in Portsmouth starts with a walk round the building and a plain list of the openings that need a rating. The buyer is often an estates lead, a facilities manager or a port operator, needing to know which doors, windows and barriers fit the risk, and in what order to fit them. The security consultancy page covers the service across the country, and this page covers Portsmouth alone.

Portsmouth gives a consultant a mixed brief. The Historic Dockyard keeps ticket desks, control rooms and stores behind a busy waterfront, the University of Portsmouth keeps receptions and offices on its city centre campus, and Portsmouth International Port keeps check-in desks and control rooms where passengers and vehicles move through the day. Gunwharf Quays holds shops and offices on the waterfront, railway stations hold ticket offices at the edge of the platforms, and city centre offices hold receptions where staff and visitors pass through one entrance.

A consultancy job runs in a set order. The survey maps each opening and the way people and vehicles reach it, the ratings are agreed with the buyer, the written specification gives a product and a rating to each opening, and supply and installation follow the specification as written. For the other work in the city, look at the physical security in Portsmouth page. You get a written reply inside one working day.

First stepSurvey of every opening on the site
OutputWritten specification for each opening
RatingsForced entry, blast, fire and vehicle ratings
ReplyAnswer in writing by the next working day

What the consultancy visit covers in Portsmouth

The visit begins at the boundary and works inward. Vehicle approaches, drop-off lanes and pedestrian routes are walked first, since the way people and vehicles reach the building sets the rating for the openings they reach. Ticket desks and control rooms at the dockyard and the port are checked for the doors and glazing round them, stores and plant rooms are checked for the doorsets that guard them, and receptions at the university and in city centre offices are checked for the entrance control that sits there. Port and station forecourts are zoned on the same lines in the transport hub requirements guide.

The visit also checks what is already in place. Existing doorsets, frames, fixings and locks are measured against the rating the opening needs, and access control points are checked for the way staff and visitors move through them. Where a doorset can stay, the specification says so, and where a frame or a fixing falls short, the specification names the change before any product is ordered. The same order of checks runs through the guide to specifying security doors in full, and the guide to specification mistakes shows where a brief most often goes wrong. Doorsets the specification most often names are listed on the security doors in Portsmouth page.

Ratings the written specification names

The grade list reaches LPS 1175 Issue 8.2 (September 2024) reaching H20 at the top. SR1 at A1 holds one minute against hand tools, SR2 at B3 holds three minutes, SR3 at C5 holds five minutes, and SR4 at D10 holds ten minutes against heavier tools, and the specification names the grade each opening needs from the tools and the time the risk asks for. Stealth attack sits under LPS 2081, the LPCB standard for rating resistance to stealth attack, and attack rated glazing sits under LPS 1270, the LPCB standard for attack-rated security glazing. Window frames that need a forced entry rating use BS EN 1627:2021, classes RC1 to RC6.

Vehicle routes take a different set of ratings. The vehicle impact ratings page puts PAS 68:2013 beside ISO 22343-1:2023. PAS 68:2013 ended during October 2023, with ISO 22343-1:2023 taking over and IWA 14-1:2013 replaced by the same standard. ProtectUK guidance for hostile vehicle mitigation allows a clear gap of up to 1,200 mm between barriers, with barrier height at least 500 mm, and the hostile vehicle mitigation in Portsmouth page covers the barrier lines on the port approaches. BS EN 1523 and BS EN 1522 give FB1 to FB7 for a control room brief that writes in a ballistic class for the room in question. BS EN 1634-1:2014+A1:2018 declares E, EW and EI marks, each holding from half an hour to two hours, on a doorset that also carries a fire rating. The ports fire door guidance page looks at compartmentation. Doors that must stay easy to open use BS 8300 and Approved Document M, with opening force below thirty newtons through the first thirty degrees and below twenty-two point five newtons beyond that.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Portsmouth sites and the openings each one holds

Portsmouth site Openings the survey lists Rating the specification names
Historic Dockyard Ticket desks, control rooms, stores SR3 doorsets and glazing
University of Portsmouth Receptions, offices, plant rooms SR2 doorsets, fire and security together where stairs need both
Portsmouth International Port Check-in desks, control rooms, vehicle drop-off PAS 68 barriers and SR3 control room doorsets
Gunwharf Quays Shops, offices, frontages SR2 shutters and windows out of hours
Railway stations Ticket offices, back-of-house corridors SR2 doorsets and entrance control
City centre offices Receptions, server rooms, plant areas SR2 doorsets and access control

Treat the table as a starting point, not as a specification. The survey sets the final rating opening by opening, since two openings of the same type can sit in very different places on one site.

Martyn’s Law tiers for Portsmouth terminals and campuses

The two tiers turn on the number of people who may be on site at one time. The standard tier is for premises holding 200 to 799 people at a time, and the enhanced tier is for premises holding 800 or more at a time. The Security Industry Authority holds the regulator role. Assent for the Act came on 3 April 2025. The start is pencilled in for spring 2027. A terminal or a campus in Portsmouth should settle its tier early, since the tier shapes the measures each premises must put in place before the products are specified.

The premises guide walks through both tiers in turn, and headcount bands for each tier are shown in the Martyn’s Law standard. Count the headcount at the busiest time for each space, since a terminal concourse at sailing time, a campus hall at lecture change and a retail frontage at peak trading each draw a different crowd. The tier that results feeds straight into the written specification, so every opening answers the same duty.

How a consultancy project runs from survey to install

Survey of the site comes first, then agreement of the ratings with the buyer, then a written specification naming the product and the rating for each opening, then supply of the products to the site, and installation last of all. Design in Portsmouth turns the survey into the written specification, manufacture in Portsmouth makes the doorsets from the surveyed sizes, and the commissioning and handover guide runs through what to look for at handover. Duties under CDM 2015 for the buyer and the site team sit in the CDM 2015 duties guide, while the work runs.

Email [email protected] with entrances, door leaves and control rooms listed, and the reply carries a rating and a written specification, arriving inside one working day. Send the site list and the opening sizes to the conflict Saffron Road, Romford, Essex RM5 3ES. Text again once the survey notes are ready and the headcount figures are to hand, and a written reply will follow inside one working day.

A rating holds only as far as the weakest opening on the line. The written specification must name the rating for every opening before any product is ordered, since one unrated door leaves the whole line open.

Portsmouth buyers ask about security consultancy

What happens on a first consultancy visit in Portsmouth?

The consultant walks the site from the boundary inward, lists every opening, and notes the way people and vehicles reach each one. That walk gives a rating for each opening and a written specification naming the product for it. The visit ends with the buyer agreeing the ratings, so supply and installation follow one written document.

What rating suits a control room at the ferry port?

A port control room usually takes SR3, since the room holds the systems that keep the terminal running. Where the room also needs a fire rating, one doorset carries both ratings. The survey confirms the grade for the room as built, since the wall and the frame round the door set the final choice. The control room doors guide covers the same mix of ratings.

Does Martyn’s Law name the products a terminal must fit?

No. The Act sets the tiers and the duties, and it names no product for any opening. Doors, glazing and barriers for a terminal are settled by the risk assessment and the survey, and the written specification names them opening by opening.

How soon does the written specification arrive?

Inside one working day the reply arrives in writing. It carries a rating and a written specification, plus a budget range. The date for the first site visit is set in the reply, and the survey then fixes the final ratings for each opening.

Ask about security consultancy for your Portsmouth building

Send the building type with the opening list and the headcount figures for each space. The written quote lists the rating and the specification for each opening on the site. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.