Certified physical security

ArxBridge
Industrial brick buildings with navy steel doors in Sheffield

Fire · EI 30 to EI 120

Thermally broken doors in Sheffield

Thermally broken doors for Sheffield hospitals, universities, shops and stations, with fire ratings, SR classes and leaf-plus-frame U-values on one order.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Sheffield
Prefer to talk?+44 7352 267239

Get a free quote in Sheffield

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Sheffield

What we supply in Sheffield

More on this

A plain steel leaf hands heat a straight path from a warm room to cold air outside. The metal carries the heat through its own body, so the inner face cools until damp from room air beads on it. A thermal break sets a poor conductor across that path, so heat must cross the poor conductor rather than run through metal, and the inner face stays warm enough to stay dry. The frame asks for the same break, because a warm leaf inside a cold frame still sheds heat at the jambs and the sill, so the opening keeps its warmth only when leaf and frame both carry the break.

Ward entrances at the Royal Hallamshire stay busy from morning to night, with waiting chairs close by. Northern General runs its department entrances the same way, and Sheffield Children’s Hospital runs family entrances where parents wait with small children. Teaching blocks and libraries at Sheffield’s two universities keep their main doors swinging all through term. Sheffield station runs its concourse doors out onto the platforms, Meadowhall runs shop fronts and service doors out onto the malls, and the Crucible runs front doors for winter audiences.

ArxBridge makes thermally broken doors for Sheffield hospitals, universities, shops and stations, and the break, the SR class and the fire rating go on each order. U-values and seals for the same openings sit in the thermal and weather performance guide. The rest of the Sheffield services sit on the page for physical security in Sheffield.

Thermal breakA poor conductor set in the leaf and frame
Fire ratingE, EW and EI, up to 120 minutes
Forced entrySR1 to SR4, chosen per opening
AccessOpening push below 30 N at first

Where Sheffield buyers fit thermally broken doors

The Royal Hallamshire runs ward entrances that stay busy all day, with waiting chairs a short walk from the door. A leaf that runs cold at that entrance lets the chill reach the chairs, and damp gathers on the floor by the threshold. Northern General runs its department entrances the same way. Teaching blocks and libraries across the two universities keep their main doors swinging all through term, and each swing lets cold air in unless the leaf holds it back.

Meadowhall runs shop fronts and service doors onto the malls, and the trading day keeps those doors moving. At Sheffield station the concourse doors face the platforms, and the wind off the tracks tests each seal. Hillsborough, Bramall Lane, the Crucible and Utilita Arena Sheffield run front and hospitality doors for crowds who arrive in wet weather. A break earns its place on each of these doors because the door opens often, the rooms behind it stay warm, and a plain leaf would show that cold as damp and draughts. For ward and clinic entrances, look at the hospital security doors guide, and for student buildings, the university security doors guide.

The break on five Sheffield doors

The table below matches a Sheffield building to its door, its break and the help that keeps the leaf true.

Sheffield building Door Break Extra
Royal Hallamshire ward entrance Entrance leaf, open all day Break in leaf and frame Closer tuned to the leaf weight
University library entrance Main leaf through term Break in leaf and frame, glazed panel Draught seal under the threshold
Meadowhall service door Leaf to the loading bay Break in the leaf, steel face Fire class held on the same leaf
Sheffield station concourse door Leaf to the platforms Break in leaf and frame, hard wearing Weather strip at head and jambs
Bramall Lane hospitality door Leaf for guests on match days Break in the leaf, slim frame Locking matched to the leaf
Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Fire class and forced entry together on one Sheffield leaf

Fire class and forced entry sit side by side on one Sheffield leaf, yet each rests on its own test, so one result never stands for the other. The written evidence should list leaf, frame and locks on one line, and the order borrows LPS 1175 Issue 8.2 (September 2024) spelling the entry class for each opening before the leaf is built. An A1 tool set is met for one minute at SR1, a B3 set for three minutes at SR2, a C5 set for five minutes at SR3 and a D10 set for ten minutes at SR4. The LPS 1175 page lists the whole scale, class by class. The dual certification guide explains how one leaf carries fire and forced entry ratings at once.

For the fire side, the test lays BS EN 1634-1:2014+A1:2018 rating the doorset as fitted. Each order states E, EW or EI with its minutes beside it, and the span is 30, 60, 90 or 120 minutes, the wall fixing which span the leaf must meet. Each class and its minutes appear on the fire ratings page, while the fire door certification guide lists what a certificate must name.

Leaf and frame heat loss in one figure

Judge heat loss by the leaf and the frame together, because the frame lets heat past at the edges where the break runs thin. A figure for the leaf alone leaves that loss out, so the order carries the pair as one number. Where the leaf holds a glazed panel, the panel figure sits beside the pair, because glass lets heat through faster than the steel round it. Meeting its own figure still leaves a leaf losing heat round a cold frame.

Closer, weight and the push at the handle

A leaf with a break weighs more than a plain leaf, so its hinges and closer carry a heavier load and the push at the handle asks for a fresh check. The push limits come from BS 8300 and Approved Document M, with 30 N at most to start the leaf moving and 22.5 N at most once it passes 30 degrees, and a closer tuned with care can hold the leaf inside those limits even when the seals push back. The threshold seal should stop the draught yet still let wheels and trolleys roll over it, and the handle should give wet hands a firm grip in winter. Opening force and thresholds for that opening are covered by the access and Approved Document M guide.

Sheffield weather tests every seal, with rain, hill wind and road salt all winter. The bottom rail needs to throw water clear of the leaf, the seals need to keep their give when the cold bites, and the threshold needs to shed water rather than let it stand. Station doors open for travellers in all weathers, while the arena and the grounds open theirs for wet match days, so each leaf must still shut true after a storm. Station and airport doors get the same treatment in the transport hub security requirements guide, which looks at the leaf on a busy frontage, while the fire rated steel doors in Sheffield page pairs a leaf with each building type.

From the survey to the price

The survey starts with the size of each opening. The surveyor notes the wall build, the floor height, the head height and the wind the door faces, with warmth behind it written beside those figures. The written specification lists the leaf build, the break, the U-value, the fire class and the SR class, and the price follows those figures, not a guess. A rated leaf already fitted stays in the plan.

Send the opening sizes, the leaf size and the fire class each wall asks for to our Sheffield college Saffron Road, Romford, Essex RM5 3ES. Tell the team which rooms sit behind each door and the leaf build is settled before a price is put on it. Email [email protected], please include the opening sizes, the leaf size and the fire class the wall asks for. One written note then sets out the specification, the price and the leaf build, so the order rests on figures, not on a guess.

Notes for Sheffield buyers

Put the break for the frame on the order as well as the leaf. A frame with no break lets heat slip past a good leaf at its edge, and the survey should spot that gap before the leaf is built.

Questions about thermally broken doors in Sheffield

Can one leaf hold a fire rating beside a thermal break?

It can, when the leaf goes through its test with the insert fitted. The certificate lists leaf, frame and locks together, and the span is 30, 60, 90 or 120 minutes.

What makes a plain steel leaf bead with damp in winter?

Cold travels through solid metal, so damp gathers on the inner face. The insert blocks that travel, and the face holds enough warmth to stay dry.

Can a leaf with a break still hold a glazed panel?

Yes, when the order carries the panel figure beside the leaf figure. Glass lets heat through faster than steel, so both figures are named before the price is set.

Does a heavier leaf call for a stronger closer?

It can do, and the closer is set after the leaf hangs. The start push is 30 N and the push after 30 degrees is 22.5 N, both from BS 8300 and Approved Document M, and the closer holds the leaf inside both.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.