Thermally Broken Doors in Cardiff
Thermally broken doors in Cardiff for the Bay, the stadium, civic buildings and hospitals. Fire rated steel doorsets with a thermal break, built to order.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Cardiff
Get a free quote in Cardiff
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Cardiff
What we supply in Cardiff
Cardiff Bay wind finds every gap in an external door, and a fire line still has to hold on the same opening. A strip of material that barely conducts heat sits inside the steel leaf and frame, breaking the metal path between inside and outside, so less heat escapes in winter and less warm air enters in summer. Thermally broken doors pair that break with a fire rating, which makes them the right choice for a Cardiff opening that must do both jobs at once.
The demand in Cardiff spreads across very different buildings. Cardiff Bay holds the Senedd building and the Wales Millennium Centre, with large public entrances facing wind off the water. The Principality Stadium holds concourses and service areas that fill on event days. Cathays Park holds civic buildings serving staff and the public every working day. Cardiff University and Cardiff Metropolitan University hold teaching buildings, and the University Hospital of Wales holds ward and plant buildings. Every one of those external doors faces Bay wind, driving rain and a long heating season.
Below, the Cardiff openings that need this doorset come first, then the fire and heat figures, then the specification for a civic building, a stadium or a hospital, then the stages from first measure to handover. The Cardiff area page lays out the wider rated protection across the city.
Cardiff openings that call for a thermally broken door
The heaviest demand sits at Cardiff Bay. The Senedd building and the Wales Millennium Centre hold large public entrances that open all day for visitors, and a door facing wind off the water loses heat fast while its thermal path through the steel stays unbroken. A break in the leaf and frame cuts that path, so the entrance loses less heat across a long day, and the cold inner face that causes condensation in winter stays warmer. Finish and sightlines should suit the building, and the specification should record both before pricing.
The Principality Stadium and the civic buildings around Cathays Park make the second set. Concourse doors and service doors at the stadium take heavy footfall on event days and stand closed for long spells between events, so the doorset must survive hard use and still hold its fire rating and its thermal break. Civic offices around Cathays Park need the same pair of duties at entrances serving staff and the public every working day. Hospital and university entrances make the remaining set: ward entrances, plant rooms and teaching buildings at the University Hospital of Wales, Cardiff University and Cardiff Metropolitan University, where an external door has to hold a fire line and keep heated areas warm through the winter.
What the fire and heat figures mean in Cardiff
Fire classes E, EW or EI, which run from half an hour to two hours, follow BS EN 1634-1:2014+A1:2018, with the furnace test behind them, and the fire ratings page lays out the classes. Heat works differently: a U-value belongs to that exact doorset, and the number should rest on test papers for that doorset, never on a figure borrowed from another product in the same range. Wales fixes the heat target for the project under Part L, Approved Document L, and that target should be written into the specification before pricing. The September 2024 issue, LPS 1175 Issue 8.2, sets the forced entry grades SR1 to SR5, and the LPS 1175 listing page names each class.
| Cardiff opening | Door duty | Class to quote | Heat note |
|---|---|---|---|
| Bay venue, Senedd or Wales Millennium Centre | Public external entrance | EI 30 or EI 60 | Break in leaf and frame, wind facing |
| Principality Stadium concourse or service door | High traffic fire rated entrance | EI 30 to EI 60 | U-value for that exact doorset, hard use hardware |
| Civic building, Cathays Park | Staff and public entrance | EI 30 to EI 60 | Break fitted, check condensation at the threshold |
| University hospital or teaching block | Door on a fire compartment line | EI 30 to EI 120 | Heat target under Part L for the project |
A Cardiff door often has two duties on one doorset: a fire class next to a forced entry class, and each needs its own test papers. The steel versus timber fire doors guide weighs up a steel leaf against a timber leaf for an opening that takes hard use, and the fire rated steel doors range covers the same duties in a plain steel doorset.
Putting a Cardiff specification together
The specification starts from the opening size, then the fire class, then the heat target, then the SR class where forced entry matters. Leaf and frame follow the size. Leaf build and seals follow the fire class. Break and glazing follow the heat target. Lock, hinges and wall fixing follow the SR class. All four belong on a single specification line where a door needs them, with test papers for each alongside. The thermal and weather performance guide puts the fire figures and the heat figures side by side on one doorset.
For a stadium or a Bay venue, hardware comes first, since concourse doors take heavy footfall and the closer and the lock must survive it. The fire door regulations for stadiums guide deals with the duties that apply to doors in a stadium. The how to specify security doors guide takes the questions in order, opening size first, hardware schedule last.
The Cardiff job, from first measure to handover
A Cardiff job opens with drawings, or a site plan where drawings are missing, showing the size of each opening and the rating wanted for it. Every opening is measured by hand on site, with the wall, the floor levels and the threshold all checked, and the access control, the closer and the power supply noted where the door carries them.
Every doorset leaves the workshop built to the specification, with the fire and U-value test papers travelling with it. Afterwards, the pack holding the fire test papers, the U-value figures and the care notes changes hands. Email [email protected] with the opening sizes and a photograph, and you hear back by the end of one working day, with the specification written out and a price range beside it.
Ask for the U-value of that doorset, not a figure for the range. A number borrowed from another product in the same range says nothing about the door you will receive.
Frequently asked questions
Do thermally broken doors suit a stadium entrance?
Yes, where the doorset is made for heavy footfall as well as fire and heat. Concourse doors at the Principality Stadium need hard use hardware, a fire class for crowded areas and a thermal break for the hours the building stands closed, and the specification should name all three.
Which U-value should I ask for in Cardiff?
The target comes from Part L, Approved Document L, for the project and the use of the room. Put the figure for the doorset as built in the specification, backed by test papers, and keep range figures out of the decision.
Can a thermally broken door carry an SR rating too?
Yes. The SR class sits beside the fire rating in the specification, and the test papers should cover the SR rating, the fire rating and the U-value of that doorset.
How is condensation handled on a Cardiff Bay entrance?
With the cold path broken, the inside face runs warmer and droplets form less often, though the survey still needs to check the threshold seals and the room ventilation still matters.
Planning a thermally broken door for a Cardiff building?
Use the quote form with the opening sizes and a photograph, and a doorset matched to the opening, the fire class and the U-value comes back priced. Get a free quote