Fire · EI 30 to EI 120
Thermally Broken Doors in Leicester
Thermally broken doors for Leicester buildings that need fire and security ratings with better thermal performance, built to surveyed sizes.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Leicester
Get a free quote in Leicester
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Leicester
What we supply in Leicester
Leicester buildings that need a rated door often need a warm door as well. A fire rated steel door on an external wall, a security door at a school entrance or a glazed doorset in a hospital corridor can lose heat through the frame and the leaf, and a thermal break is the part of the build that slows that loss while the rating stays in place.
A thermally broken doorset places an insulating break between the inside and outside faces of the frame and leaf. The break limits the path heat takes through the metal, which helps the doorset hold its thermal performance, limit condensation inside and meet the thermal requirements set by building regulations.
ArxBridge supplies thermally broken doors for buyers in Leicester who need fire, security or dual rated doorsets on external openings. The thermal break is specified alongside the rating, so the doorset is judged on both, not on one at the expense of the other.
Where Leicester buildings need thermally broken doors
Leicester is a manufacturing and logistics city with a large education and health estate. Food production units, textile and engineering works, warehouses beside the M1 and M69, and distribution buildings around the ring road hold external doors that open many times a day, and each opening is a point where heat leaves the building. Schools, colleges and university buildings add the same pattern at main entrances and sports halls.
Health buildings across Leicester use thermally broken doors where wards, clinics and imaging suites meet the outside. Leicester Royal Infirmary, community hospitals and health centres run corridors and plant rooms that need a fire rating on the door and a thermal break on the frame, because a cold internal face draws condensation and a draughty entrance wastes heat all winter. The same logic applies at student accommodation and hotels in the city centre, where entrance doors face the street and the weather.
Retail and leisure buildings bring high footfall to the same question. Highcross and the Golden Mile hold shopfronts and restaurant units with doors in near constant use, the King Power Stadium and the arena hold large public entrances, and offices in the city centre hold glazed entrance screens. A thermally broken doorset at those openings keeps the entrance usable in cold weather without giving up the fire or security rating. For the wider picture, physical security in Leicester shows where rated protection sits across each part of the city.
How a thermal break works with a security or fire rating
Steel is a good conductor of heat, so a plain steel doorset on an external wall acts as a bridge between inside and outside. The thermal break is a low conductivity section set into the frame and the leaf, breaking that bridge. The doorset still holds its fire or forced entry rating because the break is part of the tested assembly, and the rating evidence covers the whole doorset, break included.
Thermal performance and rating performance are checked separately. Fire performance is given in classes E, EW or EI, half an hour to two hours, as set out in BS EN 1634-1 in its 2014 edition with amendment A1:2018. Forced entry performance is given in SR classes under LPS 1175 Issue 8.2. That issue is dated September 2024. Thermal performance is given as a U-value for the exact doorset, and that figure should come with the test evidence for the doorset as built, not from a different product in the same range. A U-value is only stated for the exact doorset on its test evidence, never borrowed from a different product in the same range, and the thermal and weather performance guide explains how the two sets of figures sit together.
Glazing, seals and ironmongery all affect the result. A glazed vision panel should use glass matched to the rating and the thermal target, seals should close the gaps the frame leaves, and the threshold detail should suit the floor and the weather exposure. The dual certification guide explains how a doorset that carries both a fire rating and a security rating stays valid, and the steel versus timber fire doors guide sets out where steel suits an external opening.
Ratings and thermal performance for Leicester openings
Read the table as a guide only. Fire strategy or threat assessment sets the rating for each opening, and the U-value comes from the test evidence for the exact doorset.
| Leicester site | Opening | Rating | Thermal point |
|---|---|---|---|
| Schools and colleges | Main entrances and escape routes | EI 30 with LPS 1175 SR2 | Break in frame and leaf |
| Hospitals and clinics | Corridor doors to the outside | EI 60 fire rated | Limit condensation on the inner face |
| Warehouses and factories | External personnel doors | LPS 1175 SR2 or SR3 | Break plus sealed threshold |
| Student accommodation | Entrance doors and lobbies | EI 30 with LPS 1175 SR2 | Glazed panel matched to the rating |
| Retail units and restaurants | Shopfront and service doors | LPS 1175 SR2 | Break at the frame and the leaf |
| Stadiums and leisure centres | Public entrances | EI 60 with LPS 1175 SR2 | High use seals and closer |
Which standards the specification should name
Fire classes sit at the centre of this specification. Fire resistance runs in E, EW or EI classes, half an hour to two hours, to the fire test standard BS EN 1634-1:2014+A1:2018. The fire ratings page gives the classes as they stand. Forced entry uses SR1 to SR5 under LPS 1175 Issue 8.2. Each SR class appears on the LPS 1175 standard page. Where a doorset carries both ratings, the specification should name both, and the evidence should cover both.
Two details trip buyers up. A commercial door in Leicester should never name PAS 24: that standard was written for residential doors only, and the fire door certification guide explains what evidence to ask for. Thermal performance is checked against the building regulations, so the U-value asked for should be the one the regulations and the energy assessment require, stated for the exact doorset and checked on its test evidence.
From survey to fitted doorset in Leicester
Drawings or a door schedule open a Leicester project, with the rating each opening needs and the thermal target the building needs marked on them. Then a site survey measures every opening and records wall construction, floor level, weather exposure and services through the frame. The doorset is built from that survey, and the measured sizes are what hold it square, sealed and within tolerance.
Next the specification is written down, with the fire class, the LPS 1175 SR class where one applies, the U-value for the exact doorset, the glazing, the ironmongery and the finish all set out. The how to specify security doors guide explains how to keep those items in one coherent specification, and the fire door cost factors guide sets out what drives the price. Finishes are agreed at the same stage, and the powder coating service notes the colour and finish picked for the order.
Supply begins after the specification is agreed. Every rated product hands over with its test evidence, including the fire test evidence and the U-value figure for the exact doorset. For a Leicester order, send the drawings and the rating for every opening to [email protected] by email, and the reply returns a budget range and a written specification, plus a check on the rating, inside one working day. The same details can go through the quote form. For the wider door range, see fire rated steel doors, fire rated glazed doors and the keeping dual certified doors valid guide.
Ask for the U-value of the exact doorset. A figure taken from a different product in the same range does not prove the doorset you are buying, so the test evidence should name the doorset as built.
Questions about thermally broken doors in Leicester
Does a thermal break weaken the fire rating of a door?
No, where the break is part of the tested assembly. The BS EN 1634-1 fire class covers the whole doorset, break included, and the test evidence should name the doorset as built.
What U-value should a Leicester school or warehouse ask for?
The figure the building regulations and the energy assessment require. Ask for the U-value of the exact doorset on its test evidence, rather than a figure from a different product.
Can a thermally broken door also carry a security rating?
Yes, where the product is dual certified. Both the fire class and the LPS 1175 SR class belong in the specification, and the evidence should cover both.
What does a quote for Leicester need?
Start with drawings or a door schedule showing the rating for each opening, the thermal target, and the sizes or a survey request. A written specification and a budget range come back within one working day, and the rating is checked as part of it.
Planning thermally broken doors for a Leicester building? Send in the drawings with the ratings each opening needs, and a specification comes back for every opening.
Other areas
Thermally broken doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.