Fire · EI 30 to EI 120
Thermally broken doors in Bristol
Thermally broken doors in Bristol for hospitals, offices, warehouses and university buildings, with fire, security and thermal ratings explained.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Bristol
Get a free quote in Bristol
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Bristol
What we supply in Bristol
Thermally broken doors in Bristol suit entrances where the door leaf itself lets heat out of the building. A steel leaf without a break carries heat from the warm face to the cold face, so the inside surface turns cold, moisture gathers on it, and the heating plant works harder through the winter. A thermal break is a strip of insulating material set between the inner and outer skins, and it cuts that path through the metal.
Bristol has entrances of every kind, from the main door of a hospital ward to the staff entrance of a warehouse at Avonmouth. Physical security in Bristol looks at the city as a whole, while the choice at each door turns on three facts: the fire rating the opening needs, the security rating the site asks for, and the heat the leaf is allowed to lose. Bristol Royal Infirmary, the University of Bristol and the offices around Cabot Circus and Broadmead all show the same pattern, a busy entrance that must stay warm, stay shut against fire, and resist a forced entry attempt.
A thermally broken door is specified by its leaf, its frame, its seals and its hardware, and the opening decides which rating leads. A door tested for fire carries a rating under EN 1634-1, while a door on a security line carries a forced entry rating instead. Fire and security are judged apart, each on its own test evidence.
Where thermally broken doors earn their place in Bristol
The Harbourside offices and flats put a premium on a warm entrance, because a cold steel leaf at the front door draws heat out of the lobby all winter and leaves a wet patch on the floor where moist air meets the cold metal. A thermally broken leaf keeps the inside face closer to room temperature, so the lobby stays dry and the heating load falls. The same logic holds at Cabot Circus and Broadmead, where entrances open and shut all day.
Temple Meads and the depots at Avonmouth docks show the other end of the range. A station entrance or a warehouse staff door faces wind off the water and the docks, and a plain steel leaf turns into a cold bridge that chills the room behind it. Ashton Gate needs doors that serve crowds on a match day and sit quiet the rest of the week, so the leaf, the closer and the seals must all work after long idle spells.
Bristol Royal Infirmary and the University of Bristol add a further demand. A hospital ward entrance must hold a fire rating, open easily for a bed or a trolley, and keep the ward warm through the night. A university teaching block needs the same mix at its main doors, with students passing through in large numbers between lectures. Thermal and weather performance for a doorset is covered in our guide, and the design visit should map the wind, the footfall and the heating pattern before the leaf is chosen.
How the thermal break, the fire rating and the security rating fit together
The break is a layer set inside the leaf and the frame, and its job is to stop heat travelling through the metal from one face to the other. The break does not change the fire test and it does not change the security test, so the three ratings are judged apart and the doorset must pass each one on its own. The fire test for the doorset follows BS EN 1634-1:2014+A1:2018 because the rating must rest on test evidence, and the thermal break is judged on its own performance, with the rating running E, EW and EI across 30, 60, 90 and 120 minutes. Fire ratings explains what each letter means for the opening.
The security rating for the door adopts LPS 1175 Issue 8.2 (September 2024) though the fire test stays separate, and the scale runs SR1 to SR4, with tool sets A1, B3, C5 and D10, rated for 1, 3, 5 and 10 minutes in turn. A hospital ward or an office entrance often asks for SR2, while a store room or a plant room may ask for SR3 where the contents justify it. The rating covers the whole doorset, leaf, frame, locks and hinges together, so a strong leaf hung in a weak frame earns no rating at all.
Opening force matters as much as the ratings. Under BS 8300 and Approved Document M, opening the door should take under 30 N for the opening 30 degrees of swing, then under 22.5 N after that, so a person in a wheelchair or pushing a trolley can use the entrance without help. A heavy leaf with a strong closer can fail that test, so the closer is set on site and checked at handover. The Approved Document M guide covers the opening force rules in full.
Points to settle before the door is ordered
The order should name the leaf, the frame, the thermal break, the seals, the hardware and the finish, with the opening size and the fire rating agreed first. The dual certification guide shows how a single doorset earns a fire rating and a security rating at once, and keeping a dual certified door valid lists the checks that hold both ratings after the door is fitted.
| Opening | Fire rating | Security rating | Thermal detail |
|---|---|---|---|
| Hospital ward entrance | EI 60 | SR2 | Break in leaf and frame, low threshold for trolleys |
| Office main entrance | EI 30 | SR1 | Break in leaf, draught seals at head and jambs |
| Warehouse staff entrance | EI 60 | SR3 | Break in leaf and frame, seals rated for heavy use |
| University teaching block | EI 30 | SR2 | Break in leaf, closer set for high footfall |
Settle the finish with the leaf, because a door left out in all weathers needs a coating that stands up to rain and road salt. A glazed vision panel needs the same fire rating as the leaf. Fire rated glazed doors suit openings where light must pass through the leaf, and SR2 fire doors suit openings where the security ask sits at SR2.
The order of work on a thermally broken door job
Work begins at the entrance, where the team measures the opening, the frame, the threshold and the floor levels, and notes any services, steps or ramps that affect the door. The floor levels decide the threshold detail and the closer setting.
The leaf is then hung, the seals are set, and the closer is adjusted so the door shuts fully without slamming.
Handover covers the closer, the locks, the seals and the service plan. A door that opens and shuts many times a day needs its seals checked, its hinges oiled and its closer tested, with a set interval for each check in the service plan. The installation team leaves the door with its closer set and its seals tested, and that record goes with the fire safety file.
A thermal break only works when the seals and the threshold are right. A gap at the threshold lets cold air past the leaf, so the break in the metal does no good on its own.
Questions about thermally broken doors in Bristol
Do thermally broken doors stop condensation?
A thermal break keeps the inside face of the leaf closer to room temperature, so moisture in the air is less likely to gather on it. The break does not cure damp from poor ventilation, so a room that stays wet needs its ventilation checked as well as its door.
Can one door hold a fire rating and a security rating at once?
Yes, if the doorset has been tested for each rating in turn. The dual certification guide shows how the two tests sit together.
What opening force should the closer allow?
Opening should take under 30 N for the opening 30 degrees of swing, then under 22.5 N after that. BS 8300 and Approved Document M name the limit. The closer is set on site and checked at handover, because a closer set too stiff fails the test even when the leaf passes its other ratings.
Can a thermally broken door go into a listed building in Clifton?
A listed building can need consent for a new door, and the planning office for the street gives the final word. The listed building fire doors guide covers the consent route.
Our office is in Saffron Road, Romford, Essex RM5 3ES. The team there answers every enquiry.
Send the sizes and the use of the room, and we reply in writing inside one working day, the specification and the price in the reply.
Other areas
Thermally broken doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.