Certified physical security

ArxBridge
Quayside offices and navy steel entrance door beside the Tyne in Newcastle upon Tyne

Fire · EI 30 to EI 120

Thermally broken doors in Newcastle upon Tyne

Thermally broken doors for Newcastle upon Tyne hospitals, universities and offices, holding fire, forced entry and thermal ratings on the same leaf.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Newcastle upon Tyne
Prefer to talk?+44 7352 267239

Get a free quote in Newcastle upon Tyne

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Newcastle upon Tyne

What we supply in Newcastle upon Tyne

More on this

A steel leaf without a break hands heat straight from a heated room to the cold street. Metal moves heat fast, so the inner skin of a plain leaf cools, and damp from the air gathers on the cold surface. A thermally broken leaf breaks that path: a low conductivity insert splits the two skins, so heat has to cross the insert instead of travelling through solid metal.

Busy entrances are where the difference shows. At the Royal Victoria Infirmary, ward and department leaves open for staff, patients and trolleys through the day, and a warm inner skin keeps draughts off the corridor. The Freeman Hospital has the same pattern at its department entrances. Teaching blocks, libraries and student housing at Newcastle University and Northumbria University keep their main leaves in constant use through term, and the same warmth matters there. Newcastle Civic Centre, the Quayside offices, Eldon Square and the shops along Northumberland Street add public entrances where visitors come and go, and each leaf has to hold heat inside while it holds the weather outside.

Each opening needs its own answer on fire, entry and heat. A leaf that must resist fire is rated on its own evidence, and a leaf on a guarded line is rated for forced entry on separate evidence. The two ratings never share a test, and the break must leave both intact.

Door typeSteel entrance doorsets with an insulating break, for heated buildings
Thermal breakLow conductivity insert that splits the leaf skins
Fire ratingClasses E, EW and EI, in half hour steps up to two hours
Security ratingEntry classes SR1 through SR4 under LPS 1175

How the break, the fire class and the security class sit on one leaf

The insert works by cutting the metal path through the leaf. Inner and outer skins meet only through the insert, never through solid steel, so heat finds no easy route from the room to the street. The frame needs the same treatment: a warm leaf set in a cold frame still leaks heat at the jambs and the sill. Threshold, seals and ironmongery all sit on that same line, and a gap in any one of them lets heat slip past the break.

The fire evidence for the leaf rests on the test that assigns BS EN 1634-1:2014+A1:2018 against a leaf that also holds an SR class. The fire classes are E, EW and EI, each offered in half hour steps up to two hours, and the wall the leaf sits in fixes which one applies. For a leaf that must carry both a fire class and an entry class, the dual certification guide walks through the evidence each side needs, and the intumescent seals guide covers seals that swell near 200 to 250 degrees and close the edge gap as heat builds. The fire ratings page lists each class with its minutes.

Element Detail that matters What goes wrong without it
Leaf skins Insert splits the two skins Inner face cools and damp gathers
Frame and threshold Break runs through frame and sill Heat leaks at the jambs
Edge seals Intumescent and smoke seals fitted Fire and smoke pass the edges
Ironmongery and closer Closer power matched to leaf weight Leaf slams or will not shut
Glazing Rated glass set in a broken frame Glazed leaf loses heat at the pane

Where the doors earn their place in Newcastle upon Tyne

Health buildings come first. Ward and department leaves at the Royal Victoria Infirmary open hundreds of times a day, and a leaf that holds its warmth takes the chill off the corridor for patients and staff. The Freeman Hospital works the same way at its main and department entrances. On the universities, Newcastle University and Northumbria University run teaching blocks and libraries where thousands of students pass the main entrance each day, and a cold, wet leaf at that entrance gives the building a poor welcome.

Civic and retail leaves follow the same pattern. Newcastle Civic Centre takes visitors through its public entrances all day, while Eldon Square and Northumberland Street put shop and service leaves straight onto the street. Quayside offices run reception and service leaves for staff and deliveries, and a broken leaf at those openings holds the reception warm without asking more of the heating plant. The thermal and weather performance guide gives the questions to put to a supplier at each opening.

Newcastle Helix, Cobalt Business Park and Newcastle International Airport add working entrances where the leaf must serve a busy building and still hold its classes. Newcastle Central Station brings the same demand at its concourse and back of house leaves, with draughts felt by every traveller who passes through. St James’ Park and Utilita Arena Newcastle run entrances and service leaves for crowds, and a leaf that holds its shape through the seasons keeps its seals tight at every one. The physical security in Newcastle upon Tyne page covers the wider city picture, and the rating for each single opening still turns on its own wall and its own use.

Name the break in the frame too. A broken leaf set in a plain steel frame still leaks heat at the jambs, so the survey should record the break in both parts before anything is ordered.

Settling the sizes, the closer and the finish before the order

The survey measures each opening and notes how the room is used, which fire class its wall asks for and which entry class the site asks for. The surveyor fixes the entry class early: the specification selects LPS 1175 Issue 8.2 (September 2024) during the survey, and the class then stays fixed while the leaf is made. Under that issue, SR1 resists an A1 tool set for 1 minute, SR2 a B3 set for 3 minutes, SR3 a C5 set for 5 minutes and SR4 a D10 set for 10 minutes, with the class picked for each opening on its own merits.

The closer deserves the same care as the leaf. The closer power comes from BS EN 1154, whose scale runs from 1 to 7, and a fire leaf needs at least power 3, with the power matched to leaf weight and opening width. Under BS 8300 and Approved Document M, a person opening the leaf should meet no more than 30 N of resistance up to 30 degrees of travel, and no more than 22.5 N after the leaf has opened further, so the closers guide is worth a read before the power is fixed. The Approved Document M guide covers access at the same opening, and the installer tunes the push during fitting, with the handover check confirming it.

The Newcastle team takes enquiries through Saffron Road, Romford, Essex RM5 3ES, and each reply names the rating and the price. The guide for keeping dual certified doors valid explains the checks that hold both classes good once the leaf is in use, and the fire rated glazed doors page covers glazed leaves where the entrance needs light as well as ratings. The installation stage sets the frame true, hangs the leaf and tests seals, closer and lock before handover.

Questions about thermally broken doors in Newcastle upon Tyne

Do thermally broken doors stop damp on the inside face?

A break lifts the temperature of the inner skin, so airborne moisture has less reason to condense there. It cannot dry out a room where air never moves, so a damp room still needs its ventilation sorted alongside the new leaf.

Can one leaf carry a fire class and a security class together?

Yes, when test evidence covers each class on its own. Fire evidence and entry evidence are separate, and the order should name the two classes before manufacture starts.

What closer size should a thermally broken fire door take?

Leaf weight and leaf width fix the closer power. The EN scale runs from 1 to 7, and a fire leaf needs at least power 3. The installer tunes the push during fitting, and the handover check confirms it.

Will a thermally broken leaf suit a listed frontage in Grainger Town?

Consent may be needed before a leaf changes on a listed frontage, and the planning office for that street has the last say. Agree leaf, frame and finish first, so the consent matches the leaf that goes in.

Send the fire class and the sizes at [email protected] and a written answer lands within one working day, naming the closer size and the price.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.