Fire · EI 30 to EI 120
Thermally broken doors in Glasgow
Thermally broken doors for Glasgow hospitals, universities and offices, with fire, forced entry and thermal ratings held on the same surveyed leaf.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Glasgow
Get a free quote in Glasgow
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Glasgow
What we supply in Glasgow
A thermally broken door in Glasgow keeps heat on the right side of the leaf while holding its fire rating and its forced entry rating. The break in the frame stops the cold path through the metal, so the inside face stays warm and the frame stays dry.
Leaf, frame, seals and closer work as one set. A warm leaf on a cold frame still sweats at the edges, and a strong leaf on weak seals still lets in draughts, so the specification names the thermal break, the fire class and the SR class as one set for one leaf. Thermally broken doors suit entrances that face the weather all day.
Glasgow gives those entrances hard weather. Wind and rain off the Clyde drive at west facing doors, and cold snaps test every seal on a hospital or university entrance. Doors on Buchanan Street frontages, at the SEC Centre and at Glasgow Airport face the same pattern, and the physical security in Glasgow area page covers protection across the city in full.
Where Glasgow buildings fit thermally broken doors
Hospitals and universities fit them at entrances in use all day. Glasgow Royal Infirmary needs a door that holds heat at reception while taking trolleys and foot traffic through the day, and a university entrance needs the same warmth at the doors students use between lectures. The hospitals guide covers the hospital door, and the education sector page covers the campus entrance.
Retail and office frontages bring a different pattern. Doors on Buchanan Street and across Merchant City open and shut all day, and office doors at St Enoch and Buchanan Galleries face the same wear, so the break in the frame matters as much as the leaf. The commercial buildings guide covers the office and shopfront door, and the thermal break keeps the inside face warm through the working day.
Public and event buildings follow the same logic. Entrances at the SEC Centre and at Glasgow Airport take crowds in waves, and a door that holds its heat while holding its fire class suits both. The dual certification guide covers a leaf tested for fire and forced entry together.
Fire, forced entry and thermal ratings together
Fire classes run E, EW and EI, covering 30 to 120 minutes, and leaf, frame and seals must all carry the same class. The fire test mentions BS EN 1634-1:2014+A1:2018 hence the evidence must name the same leaf that is fitted. Intumescent seals swell shut once heat reaches around 200 to 250 degrees, and gaps sit at 4 mm at the edges. Closers run in power sizes EN 1 to EN 7, with a minimum of EN 3 on fire doors. The push a door needs is capped by BS 8300 and Approved Document M: 30 N until the leaf passes 30 degrees, then 22.5 N after that. The fire ratings page carries the classes in full, the door gaps guide covers the 4 mm gap, and the door closers guide covers the closer sizes.
The forced entry class shares the leaf with the fire class. The written specification assigns LPS 1175 Issue 8.2 (September 2024) therefore the SR class is named on the same leaf as the fire class, and the two classes are checked on the same evidence. SR1 sits at class A1 with one minute of delay, SR2 at class B3 with three minutes and SR3 at class C5 with five minutes. For the full SR class list, open the LPS 1175 page. PAS 24 stays a residential test, so it is never named for a commercial door.
The thermal break and the hardware finish the set. The break stops the cold path through the leaf and the frame, the seals hold the draught out, and the threshold breaks the same cold path at the foot of the door. A 1-star cylinder with 2-star hardware gives 3-star protection, and levers sit at grade B or B1. The thermal performance guide covers the break and the seals, the door hardware guide covers the levers and the lock, and the fire door certification guide covers the evidence for the fire class.
A short guide to Glasgow door sizes and classes
Treat the table below as a rough guide only. The survey of the opening decides the classes for every door, weighing the use, the fire strategy and the hours the entrance lies open.
| Glasgow use | Leaf and frame | Classes to ask for | Hardware |
|---|---|---|---|
| Hospital entrance | Thermally broken leaf, steel frame | EI 60, LPS 1175 SR2 | EN 3 closer, 3-star cylinder |
| University entrance | Thermally broken leaf, glazed panel | EI 60, LPS 1175 SR2 | EN 3 closer, panic bar |
| Office frontage | Thermally broken leaf, narrow frame | E 30, LPS 1175 SR2 | EN 3 closer, lever handles |
| Retail entrance | Thermally broken leaf, glazed panel | E 30, LPS 1175 SR2 | EN 3 closer, 3-star cylinder |
| Public building entrance | Thermally broken leaf, steel frame | EI 60, LPS 1175 SR3 | EN 4 closer, panic bar |
How a Glasgow door order runs
Begin with the opening. Measure the leaf size, the frame condition, the threshold and the swing, and check the access needs at the door, since the opening force and the handle height shape the hardware from the start. A door that opens onto a busy corridor needs its swing and its clear width settled before the leaf is ordered, and the survey notes the fire strategy for the opening at the same visit.
Settle the leaf, the break and the seals next. The thermal break sits inside the leaf and the frame, cutting the cold path at both, the seals sit at the head, the jambs and the threshold, and the closer is sized to the leaf mass and the daily swing count. The closer power, the cylinder star rating and the lever grade are named on the specification with the fire class and the SR class, so no part is ordered on its own.
Finish with the fitting and the handover. Our survey team works out of Saffron Road, Romford, Essex RM5 3ES. The maintenance in Glasgow service looks after the seals and the closer after handover.
A thermal break in the leaf alone proves nothing. The frame, the seals and the threshold must break the same cold path, or the door will sweat at the edges in a Glasgow winter.
Glasgow questions, answered plainly
Can a thermally broken door keep its fire class?
Yes, and each is tested apart on the same leaf. Fire classes run E, EW and EI, covering 30 to 120 minutes, the thermal break stops the cold path through the leaf and the frame, and the evidence must name both on the leaf that is fitted, with the seals and the closer matched to the same leaf.
What gap should a Glasgow fire door hold?
4 mm at the edges. The gap is checked at handover and at each inspection after it, since a gap that grows lets smoke and heat past the leaf, and a gap that closes makes the door bind in the frame. In a fire the intumescent seals swell at roughly 200 to 250 degrees and shut the gap.
Which closer size fits a fire door?
A closer for a fire door runs in power sizes EN 1 to EN 7, and EN 3 is the minimum. The size is picked for how heavy the leaf is and how often the door swings daily. The force cap eases from 30 N to 22.5 N once the leaf passes 30 degrees of swing, so the door shuts on its own without fighting the user.
How strong should the lock cylinder be?
A 1-star cylinder with 2-star hardware gives 3-star protection, and the two parts are named together on the specification. The cylinder alone does not give the rating, and the hardware around it must carry the same star level, so the lock, the cylinder and the handles are ordered as one set.
Send the sizes and the fire class to [email protected]. We answer in writing, within one working day.
Other areas
Thermally broken doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.