Blast · ISO 16933 EXV45 to EXV10
Blast Resistant Windows in Nottingham
Blast resistant windows for Nottingham offices, hospitals, universities, the station and Victoria Centre, built as rated units to ISO 16933.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Nottingham
Get a free quote in Nottingham
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Nottingham
What we supply in Nottingham
A blast resistant window in Nottingham is ordered as one tested assembly rather than as a pane by itself. Glass, frame, bead and fixing are proved as a set, so the opening holds shut when a blast load reaches it. That assembly is the right answer wherever glazing looks onto a road or a crowded pavement: offices beside Nottingham station, shop fronts in Victoria Centre, ward glazing at Queen’s Medical Centre and lecture rooms at the city’s two universities. A pane that breaks apart throws sharp fragments a long way from the blast, which is why each assembly is rated to stay whole and to stay fixed in the wall.
The class sits with the assembly as fitted, not with the pane alone. A thick pane held in a shallow frame, or a sound frame anchored to a weak wall, returns a poorer result than the pane reached on its own in the test rig, so the written specification names glass, frame, bead and fixing side by side, and the surveyor tapes the reveal at each opening. Around Nottingham Castle, the Lace Market and Old Market Square the streets hold people late into the evening, and glazing there carries the same risk as the doors beside it. Our physical security in Nottingham page gives the picture across the whole city.
ArxBridge makes blast resistant windows for Nottingham buyers who want every opening matched to the threat outside it, building each assembly to the size of the opening it fills. Street facing glazing at ground level takes the strongest classes, glazing higher up the building takes lighter ones, and the room behind the pane decides the class as much as the floor does.
Nottingham streets that put windows at risk
Ground level glazing on the street side takes the rating first. Offices beside Nottingham station, shops in Victoria Centre and civic buildings by Old Market Square look onto traffic that passes all day, so a single line of the written specification pairs a blast class and a forced entry grade on one line. A blast class by itself says nothing about forced entry. Our forced entry, ballistic and blast ratings comparison lays it out.
At Queen’s Medical Centre and the two universities, the class is fixed opening by opening. A ward pane, a pharmacy pane and a plant room pane each meet a separate risk, and across the universities a laboratory, a library and student rooms call for separate classes again. Fixing the class opening by opening puts the spend where the risk sits and keeps a heavy class off an opening that a lighter one protects.
Crowded buildings form the third group. The Motorpoint Arena, the National Ice Centre, Trent Bridge, Victoria Centre and Nottingham station each pull large numbers of people into a tight footprint, and each falls under the crowded premises duties of Martyn’s Law. Where glazing at those buildings meets a vehicle route, a blast class forming part of its physical layer is needed. Our blast resistant windows cost and specification pages carry more on the glazing side.
The castle quarter sets a different puzzle. Tight streets and old masonry around Nottingham Castle and the Lace Market give shallow reveals and thin walls, so the way the unit is anchored counts as much as the class itself. An assembly that fits a new office beside the station rarely fits a stone reveal in the Lace Market, and the survey records the wall build at every opening before the class is settled.
A class for every Nottingham window
Open the discussion with the table below. The threat assessment fixes the closing class for each window, agreed with the consultant or the site team, and the price follows from that.
| Site in Nottingham | Window | Class | Unit |
|---|---|---|---|
| Offices beside Nottingham station | Ground level glazing on the street side | EXV or SB, set by the assessment | Fixed lights in one rated assembly |
| Hospital and the two universities | Ward, laboratory and plant room glazing | ISO 16933 class plus SR2 or SR3 | A single assembly tested for blast and forced entry |
| Arena, ice centre and Trent Bridge | Ticket hall and concourse glazing | EXV class from the assessment | Laminated panes in one rated assembly |
| Victoria Centre shops and hotels | Shop fronts and restaurant glazing | ISO 16933 class with a hazard grade | Opening lights in one rated assembly |
| Castle quarter and Lace Market | Entrance glazing and foyer glazing | ISO 16933 class plus SR2 | Steel frame holding laminated panes |
Getting the window specification right in Nottingham
Start from the floor level, the way the window faces, the space between road and pane, and the threat assessment for that opening. Together those four points settle the class under ISO 16933. The specifying security doors guide sets out the other points to agree before a price is given. The specification lists LPS 1175 Issue 8.2 (September 2024) beside the blast class where a forced entry grade is also wanted, and SR2 is class B3, a point the LPS 1175 page explains in turn, starting with the lightest tool set and ending with the heaviest. The ISO 16933 EXV versus SB guide runs through the two scales. Every class sits on the blast ratings page.
Glass, frame, bead and fixing each take one specification line, the test record for the quoted class sitting beside them. Finish, opening lights, ventilation and the access control interface share that line, and a fire rating is added on it where the window has a fire duty as well, so fire duty and blast duty reach handover in a single document. The handover pack records BS EN 1634-1:2014+A1:2018 beside the fire section when the window carries a fire rating too, with the classes listed on the fire ratings page. For the fire side, with class and frame depth, see the fire rated windows guide.
Charges carried by a vehicle are scored on the EXV scale, fixed by charge size and stand off, and charges carried by hand are scored on the SB scale. Every pane takes a hazard grade: grade A for no break, grade F for high hazard, and the frame grade has to match the pane grade, since a weak frame still passes the pressure wave through even with a sound pane. Pane types that suit a blast class without help from the frame are listed on the blast resistant glass page, and our blast resistant windows cost and specification pages take the glazing side further.
From survey to handover in Nottingham
A survey opens the job. Each opening is measured and taped, with the wall build and the reveal depth written down at every one, and the surveyor notes floor level, services that pass through the frame, escape routes and how the room is used day to day. Those notes decide the size and the fixing method, so each assembly is made for the opening it fills.
Manufacture follows the signed specification, and each unit reaches site with its test records beside it. The security door maintenance checklist covers the checks a unit needs once it is in use. Fitting and handover are taken on by the installation service.
Send the class wanted at each window, with the gap between road and glass, in a note to [email protected]. An answer reaches you inside one working day, bringing a specification with a class check and a price range, all in writing.
Frames, beads and fixings
A class that fits a window in another city rarely fits one here. Send the road to glass gap at each opening, and the class for that opening is worked out from those figures, never borrowed from a class used elsewhere.
Nottingham blast window questions
How is the ISO 16933 class fixed for a Nottingham shop window?
The assessment for that opening fixes it. Charge size and the distance from road to glass are weighed side by side, with the EXV scale for a charge carried by a vehicle, the SB scale for one carried by hand.
Can one Nottingham window carry two ratings at once?
Yes, when one test record covers both ratings on the same assembly. Put both classes on a single specification line, ISO 16933 with the SR grade, and attach the record that proves each one.
Do arena windows in Nottingham need a blast rating?
Glazing at the Motorpoint Arena, the National Ice Centre and Trent Bridge that looks onto a vehicle route usually needs one. The crowded premises duties of Martyn’s Law reach the whole building, so glazing on those elevations forms part of the physical layer.
What should I send with a Nottingham window enquiry?
Send the drawings, the road to glass distance and the class wanted at each window. The first answer brings a specification, a price range and a check on the class, and it reaches you inside one working day.
Want a blast resistant window in Nottingham?
Send your drawings and the class for each opening, and every window is matched to a tested unit built for that opening. Get a free quote
Other areas
Blast resistant windows in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.