Blast · ISO 16933 EXV45 to EXV10
Blast resistant windows in Manchester
Blast resistant windows for Manchester offices, schools and hospitals, with EXV and SB classes, glazing choices and a written specification.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Manchester
Get a free quote in Manchester
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Manchester
What we supply in Manchester
A Manchester building with large glazed fronts needs windows that let in daylight and still hold under a blast load. Offices in Spinningfields, shops in the Northern Quarter and flats above Deansgate all sit behind glass, and a blast resistant window is the point where daylight, view and protection meet in one assembly.
Blast resistant windows are tested as a set, not in parts. The glass, the frame, the fixings and the wall around the opening are tested together, so the rating covers the whole window and not the pane alone. A pane that holds and a frame that gives way is no rating at all.
Manchester adds its own settings to that choice. The Northern Quarter holds small shops and bars behind narrow glazed fronts, Deansgate holds tall flats above shops, Spinningfields holds offices behind full height glass, and Manchester Airport holds terminals where crowds pass wide glazed walls. Each setting puts a different load on the window, and the class follows the setting.
Where Manchester sites need blast resistant windows
Offices and shops in the city centre plan around glass that stays in use all day. A Spinningfields office needs daylight across deep floors, a Northern Quarter shop needs a frontage that shows its goods, and a Deansgate flat needs light above a busy street. The window for each one is graded for the load it may face, and the Manchester area page shows how those glazed fronts sit beside offices, flats and shops across the city.
Health and education sites plan around rooms that cannot be shut off from light. Manchester Royal Infirmary needs ward windows that let in daylight while the entrance stays controlled, and the University of Manchester needs laboratories and libraries where students work beside large windows for hours. The healthcare sector page sets out how hospital windows and doors are planned around wards and departments, and the education sector page covers schools and universities in the same way.
Studios and travel sites plan around wide glass and large numbers. MediaCityUK holds studios behind glazed walls that face the water, and Manchester Airport holds terminals where crowds pass wide glazed fronts at every hour. A window for those sites is set beside the doors and the entry lanes, and the window costs page shows what sets the price of a rated window.
Blast and glass classes for a Manchester window
The schedule enters LPS 1175 Issue 8.2 (September 2024) per the standards list, with SR2 as class B3. Forced entry is graded by the tool set used against the window and the time it must hold, with SR1 as class A1, SR3 as class C5 and SR4 as class D10 above it. Every class in the range appears on the LPS 1175 standard page. The keeping a rating valid guide shows how the rating is kept after the window is fitted.
Blast performance is graded on its own scale. ISO 16933 sets EXV and SB classes for the blast load, while EN 13123 and EN 13124 set EPR and EXR classes for the window assembly under blast. The class is fixed by the pressure, the duration and the debris the assembly must hold back, and the blast ratings page lists each class in full. The ratings compared page puts the three duties beside each other on one window.
The glass itself carries its own classes. EN 1063 sets BR1 to BR7 classes with SG1 and SG2 for the glass, while EN 1522 and EN 1523 set FB1 to FB7 classes with FSG for the frame and glazing. The pane, the frame and the fixings are graded as one assembly, and the ballistic ratings page lists each class in full. The ballistic glass ratings page explains how the glass classes read on a rated window, and the choosing a rating page explains how one opening gets its class.
How to specify blast resistant windows in Manchester
The work starts with the opening and the light it must give. Measure the width and height of each window, the wall build around it and the sill height above the floor, then settle the blast class the site needs. A ground floor shop front that faces a street needs a different class from a third floor office window, and the window cost page shows how the size and the class set the price together.
Then work through glass, frame and fixings together. A fixed pane suits a wall where no one needs to open the window, while an opening light suits a room that needs air as well as light. The frame and the fixings must match the pane, since a strong pane in a weak frame holds no rating, and the acceptance and snagging guide shows what to check on each window before it is signed off.
Then settle the opening gear, the locks and the finish. An opening light needs hinges and a lock that suit the pane weight and the daily use, and a fixed pane needs a finish that suits the facade around it. The installation service page shows how the windows are fitted into the wall, and the design service page shows how the window sizes are drawn into the facade.
| Manchester use | Window form | Class to ask for | Glazing |
|---|---|---|---|
| Spinningfields office floor | Fixed pane, full height | EXV class, SR2 | Laminated, BR rated |
| Northern Quarter shop front | Fixed pane, street level | SB class, SR2 | Laminated, BR rated |
| Deansgate flat above shops | Opening light, upper floor | EXV class, SR2 | Laminated, BR rated |
| Manchester Royal Infirmary ward | Fixed pane with opening light | EXV class, SR2 | Laminated, BR rated |
| MediaCityUK studio wall | Fixed pane, wide span | SB class, SR2 | Laminated, BR rated |
Project steps for blast resistant windows in Manchester
Each window position is surveyed before anything is ordered. The surveyor measures width, height, sill height and wall build, and notes the rooms behind each window and the routes between public and staff areas. A photo and a sketch of every opening go into the specification file.
Next the record names the rating and the window form: blast class, forced entry class, glass, frame, fixings, opening gear and finish, all named for each opening. Its evidence file travels with the rated window. The written specification goes out from our office, on Saffron Road, Romford in Essex, RM5 3ES.
Fitting is planned around ward hours, teaching times and trading hours when the programme lets us. Send the size of every opening, with the blast class it needs, to [email protected]. Within one working day you receive the specification, with the rating checked, plus the budget range in writing.
Check the frame and the wall with the glass. A window rating covers the pane, the frame and the fixings that hold them in the wall, so a weak surround leaves the rating with nothing to stand on.
Questions about blast resistant windows in Manchester
Can a blast resistant window still open?
Yes, where the design allows it. An opening light is graded with the pane and the frame as one assembly, and the hinges and lock must suit the pane weight. A fixed pane suits a wall where no one needs air from that window.
Does the glass alone carry the rating?
No, not on its own. The pane, the frame and the fixings are graded as one assembly, so a strong pane in a weak frame holds no rating. The specification names the frame and the fixings beside the pane for that reason.
What class should a Manchester shop front window carry?
The risk at that frontage sets the class. A street level shop front faces a different load from an upper floor office window, and the class follows the pressure, the duration and the debris the assembly must hold back. The schedule names a class for each opening.
Who looks after the windows after fitting?
On a planned visit the pane, the frame, the hinges and the lock on each opening light are checked, and worn parts are changed before they fail. The contract scope page explains what a contract covers.
Planning blast resistant windows for a Manchester site? Share the opening sizes and the blast class each window needs.
Other areas
Blast resistant windows in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.