Certified physical security

ArxBridge
Waterfront offices with glass entrances and bollards in Cardiff

Blast · ISO 16933 EXV45 to EXV10

Blast resistant windows in Cardiff

Blast resistant windows in Cardiff, from Bay flats to hospital wards, with rated frames and glazing, a written specification and a one working day reply.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Cardiff
Prefer to talk?+44 7352 267239

Get a free quote in Cardiff

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Cardiff

What we supply in Cardiff

More on this

A window on a Cardiff street serves light, air and protection in one unit. It lets light and air into the room behind it, while holding its pane in the frame when a blast wave reaches the front of the building. A fixed window at a Bay office, an opening window at a flat in Cathays and a tall window at a hotel near the Principality Stadium all face the same street, yet each one needs a different frame, a different opening gear and a different fixing into the wall. Each blast resistant window from ArxBridge is built to dimensions measured at its own opening, so the frame sits square against the wall and the sash closes onto its seals.

Cardiff gives a window a wide range of rooms to serve. Flats around Cardiff Bay look over the water from glazed fronts, student rooms in Cathays sit behind windows that open every day, and houses in Roath and Canton hold families behind windows that have to keep the weather out as well as the street. The University Hospital of Wales at Heath keeps wards behind windows that have to stay safe for patients. For the city as a whole, the rest of the Cardiff security work is listed on the physical security in Cardiff page.

No window goes into production before a surveyor has visited the opening, the rating has been put down in writing, and a specification has listed the frame, the glass, the opening gear and the fixing. A window that looks right on a sample card can still fail at the sill when the wall around the opening is not square, so the surveyor notes the opening size, the wall condition and the sill in the same visit. The rating follows the risk assessment for the building rather than the size of the window.

Window typesFixed, opening and tilt windows
RatingsEXV and SB to ISO 16933
FramesSteel, aluminium and timber frames
Reply timeOne working day

Where Cardiff windows carry a blast rating

Waterfront flats take the most visible use. A flat around Cardiff Bay looks over the water from a glazed front, and the window there has to hold its pane while the flat stays bright. At the Wales Millennium Centre and the St David’s Centre, tall windows light the foyers where crowds gather, and the frames there have to carry a heavy pane without a thick sight line.

Rooms that open every day use the window in a quieter way. A student room in Cathays opens its window for air each morning, and the sash must still close onto its seals after a year of daily use. At the University Hospital of Wales, a ward window must open for air and close firmly at night; a sash that drops on its hinges leaves a gap the rating cannot cover. Houses in Roath, Canton and Llandaff hold families behind windows that face the street.

Ratings, frames and the glass inside the window

The rating to name first is the blast rating for the window as a whole. ISO 16933 gives EXV ratings for a window tested against a vehicle borne charge at a set distance and SB ratings for a window tested against a charge in a satchel or a similar small package, with the two test routes set out on the EXV and SB ratings page. Under the European test series EN 13123 and EN 13124, windows, doors and shutters tested against a blast carry EPR and EXR classes, and those classes appear on the blast ratings page.

A blast rating does not stand on its own, because other ratings cover different threats for the same window. For forced entry, the frame is rated under LPS 1175: SR1 resists the A1 tool set for 1 minute, SR2 resists B3 for 3 minutes, SR3 resists C5 for 5 minutes and SR4 resists D10 for 10 minutes, and the three ratings compared page shows how the three rating kinds differ. Where a window must also hold back a bullet, the classes run FB1 to FB7 for bullets and FSG for shotgun pellets under EN 1522 and EN 1523, and the guide to choosing a ballistic rating explains how to pick the class. Film on a pane is a different answer again, and the blast window film page explains what film can and cannot do for an existing window.

Window Best place for it Rating to name
Fixed blast window Bay offices and foyers with long runs of glazing ISO 16933 EXV or SB
Opening blast window Student rooms and wards that open every day EN 13123 and EN 13124 EPR or EXR
Tilt blast window Rooms that need air without a wide open sash ISO 16933 SB
Blast window frame Street fronts where forced entry also matters LPS 1175 SR1 to SR4

Name the window rating on the specification before the order is placed. A window sold only as strong hands the buyer no test record to show at the fitting check.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Survey, fitting and the written specification

The survey looks at how the window will close after a year of daily use, not only on the day it is fitted. It notes the opening size, the fall of the sill, the condition of the wall the frame stands in and the height of the window above the pavement, because a window that fails at height drops shards below. The written specification describes LPS 1175 Issue 8.2 (September 2024) giving the forced entry hold time for the frame, the lock and the hinges in one place, so the buyer can check the blast rating and the forced entry rating on the same sheet.

A sash hung before the frame is level will drop on its hinges within a year, so the frame is levelled and fixed before the sash goes in, and the gear is set so the sash closes onto its seals along the full length.

The Romford base: Saffron Road, Romford, Essex RM5 3ES, write to the survey team with the window sizes and the rating for each opening; the reply after it names the frame and the glass that fit those openings. PAS 68:2013 left use on 25 October 2023 and its vehicle impact work is now carried by ISO 22343-1:2023, so a window beside a road where a vehicle could reach the front should name the current standard. The items that push a price up or down are listed on the blast resistant windows cost and specification article, and the guide to lead times and programme risks explains the time a rated order takes from survey to fitting.

Care after fitting

A rating lasts only while the window, the frame and the fixing stay as tested. A sash forced past its stay, a hinge swapped for a lighter one, or a pane changed for a thinner one all change the tested unit, so each change must be checked against the specification first. The cleaning routine must leave the seals and drainage slots alone, and any sash that drops or seal that gaps must be reported the day it is found.

At the University Hospital of Wales and in student rooms in Cathays, a window that will not close cannot wait for a routine round, so the buyer should keep the specification and test evidence where the facilities team can reach it. A yearly look at the hinges, seals and fixings catches small faults before they grow, and the check takes the same form each year so the record can be compared year to year.

Questions from Cardiff buyers

Can an opening window carry a blast rating?

Yes, where the window is tested as a whole with its opening gear. A fixed window suits a foyer that never opens, an opening window suits a room that needs air every day, and the survey records how the sash will be used before the frame and gear are named on the specification.

What does EXV mean for a window beside a busy street?

EXV ratings come from a test against a vehicle borne charge at a set distance, so a window beside a road where vehicles pass close to the front is the case where the rating is most often named. The risk assessment for the building decides which rating the specification names.

Will a blast resistant window change the look of an older frontage?

It can, where the frame has to be deeper to take the pane, so the survey notes the frontage and the frame depth before any window is ordered. A frontage with a listing, or one in a conservation area, needs a word with the local planning authority first, before the specification is settled.

How long does a window order take from survey to fitting in Cardiff?

You hear back from the survey team within a working day. The survey settles the opening sizes, the frame and the glass, and once the measurements are checked and production has started, the team books the fitting day with you.

Send the window sizes and the rating for each opening over to [email protected] once you have the opening list, and the reply that follows inside one working day names the frame and the glass and the next step.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.