Blast · ISO 16933 EXV45 to EXV10
Blast resistant windows in Bristol
Blast resistant windows for Bristol offices, hospitals and shops across the city, with EXV and SB classes, glazing choices and a written specification.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Bristol
Get a free quote in Bristol
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Bristol
What we supply in Bristol
In Bristol, a window earns its blast grade only when pane, frame, fixings and surrounding wall are judged as a single unit. Testing puts those parts under load together, so the grade describes the complete opening and the force it is expected to resist. When the pane survives yet the frame bends away, the opening has earned no grade, and the written brief lists each component next to the glass.
Blast resistant windows bring daylight to rooms that still require a graded frontage. Harbourside offices, Cabot Circus and Broadmead shops, and wards at Bristol Royal Infirmary spend much of the day behind glass, and a graded window preserves that daylight while the opening holds a recognised class. That class shifts with the setting, so a pavement level shopfront and an office window on an upper floor are judged against different loads.
Bristol brings its own mix of settings to the decision. Wide glazed walls at Bristol Temple Meads stand behind crowds, terminals at Bristol Airport put travellers beside glass through every hour, and Avonmouth and Filton industrial sites place glazed fronts opposite yards and roads. Each place presses the window in a different way, and the opening size, the wall construction and the activity in the room behind it decide the grade.
Bristol buildings that sit behind wide glass
City centre offices and shops organise their days around glass in constant use. A Harbourside office wants daylight reaching deep into its floors, a Cabot Circus shop wants a frontage that displays its stock, and a Broadmead store wants a pavement level window facing the street. Each window takes a grade matched to the load it might meet, and the physical security in Bristol page places those glazed fronts among offices, flats and shops across the city. Shops and shopping centres receive the same treatment on the retail sector page.
Health and education buildings organise their rooms around light that lasts for hours. Bristol Royal Infirmary wants ward windows that admit daylight while the entrance remains under control, Southmead Hospital wants glazed fronts across departments that operate through the day, and the University of Bristol wants libraries and laboratories where students sit beside large windows. Hospital windows and doors around wards and departments are covered on the healthcare sector page, and schools and universities are covered on the education sector page.
Blast classes and forced entry grades for a Bristol window
The schedule identifies LPS 1175 Issue 8.2 (September 2024) instead of relying on a class recalled from memory, and it pairs SR2 with class B3. Forced entry grading weighs the tools brought against the window and the minutes it must resist, giving SR1 class A1 for 1 minute, SR3 class C5 for 5 minutes and SR4 class D10 for 10 minutes. The full range sits on the LPS 1175 page, while the guide comparing SR2, SR3 and SR4 puts the three grades side by side.
Blast performance uses a separate scale. Under ISO 16933, a window earns an EXV or SB class against the blast load, and EN 13123 plus EN 13124 give EPR and EXR grades to the whole assembly under blast. Pressure, duration and flying debris decide the class, and the blast ratings page carries the complete list. The EXV and SB classes guide shows how the two blast scales read across a single window.
Glazing has its own set of classes. EN 1063 gives BR1 to BR7 for the glass, with SG1 and SG2 alongside, while EN 1522 and EN 1523 grade the frame with its glazing from FB1 to FB7, with FSG alongside. Pane, frame and fixings share a single grade as one unit, and the ballistic ratings page carries the complete list. The ballistic glass ratings page shows what each glass class means on a graded window, and the ratings compared page places the three duties side by side at one opening.
Putting a Bristol window specification together
Start with the opening and the daylight it has to provide. Record each window’s width and height, how the wall around it is built and how high its sill sits above the floor, then fix the blast class the site requires. A pavement level shopfront facing a street takes a different class from an office window on a third floor, and the window costs page shows how size and class shape the price together.
Then consider glass, frame and fixings as one group. A fixed pane fits a wall where the window never needs to open, while an opening light fits a room that wants air as well as light. Frame and fixings have to equal the pane in strength, because a tough pane set in a feeble frame earns no grade, and the acceptance and snagging guide gives the checks to run on each window before sign off.
Then settle the hinges, the locking and the finish for each opening. An opening light wants hinges and a lock matched to the pane weight and to daily use, and a fixed pane wants a finish that fits the facade around it. How windows are set into the wall is covered on the installation service page, and how window sizes take shape in the facade drawings is covered on the design service page.
| Bristol setting | Window type | Grade to request | Pane build |
|---|---|---|---|
| Harbourside office floor | Full height fixed pane | EXV class, SR2 | BR rated laminated pane |
| Cabot Circus shop front | Street level fixed pane | SB class, SR2 | Laminated pane to BR class |
| Ward, Bristol Royal Infirmary | Fixed pane and opening light | EXV, SR2 | BR rated laminated pane |
| University of Bristol library | Upper floor opening light | EXV class, SR2 | Laminated pane, BR class |
| Bristol Airport terminal | Wide span fixed pane | SB class, SR2 | FB rated laminated pane |
From survey to fitted window in Bristol
Survey each window position before any order is placed. The surveyor records width, height, sill height and wall construction, then notes which rooms sit behind each window and how public and staff routes run past them. A photograph and a sketch of every opening are filed in the specification file.
The record then names the rating and the window form for each opening: forced entry class and blast class, then glass, frame, fixings, finish and opening gear. Its evidence file stays with the rated window.
The written specification is issued from Saffron Road, Romford, Essex RM5 3ES. Fitting work is timed to suit ward routines, lecture timetables and shop opening periods where the programme allows. Share the dimensions of each opening, along with the blast class required for it, at [email protected]. Expect an answer inside one working day, confirming the rating and giving a budget range in writing.
A pane that stays put while its frame shifts proves nothing. Ask for the frame, the fixings and the wall construction to be listed beside the pane, because the grade rests on all three together.
Questions about blast resistant windows in Bristol
Can a blast resistant window in Bristol still open?
Yes, when the design permits an opening light. That light is graded together with the pane and the frame as a single unit, and its hinges and lock have to suit the pane weight. A fixed pane fits a wall where the window never needs to admit air.
Does the pane alone carry the rating?
No, never on its own. The grade belongs to pane, frame and fixings together, so a tough pane set in a feeble frame earns no grade. The brief lists frame and fixings next to the pane, so nothing is left unnamed.
What class suits a shop front in Cabot Circus?
Risk at that frontage decides the class. A pavement level shopfront meets a different load from an office window on an upper floor, and the class follows pressure, duration and flying debris. The schedule gives a class for each opening.
Who checks the windows after fitting?
During a planned visit, each opening light has its pane, frame, hinges and lock inspected, and parts showing wear are renewed before they break down. For the items a contract includes, see the contract scope page.
Working on blast resistant windows for a Bristol site? Tell us each opening size and the blast class its window requires.
Other areas
Blast resistant windows in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.