Blast · ISO 16933 EXV45 to EXV10
Blast Resistant Windows in Aberdeen
Blast resistant windows in Aberdeen for hospital, university and harbour buildings, rated to ISO 16933 and EN 13123, with a written quote in one working day.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Aberdeen
Get a free quote in Aberdeen
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Aberdeen
What we supply in Aberdeen
Aberdeen city centre holds offices, civic buildings and shops along Union Street, and the harbour, the airport and the two universities each hold buildings where a glazed opening must do more than let light in. A hospital ward, a university laboratory, a harbour office and an airport building all need windows that hold a blast rating while the room behind them keeps working. The window for each opening is chosen from the rating the site faces, the size of the opening and the frame the wall can take.
Wards and clinical rooms at Aberdeen Royal Infirmary need a window that holds its rating and still gives light and air. Laboratories and teaching rooms at the two Aberdeen universities sit with glazed walls beside busy walkways. Marischal College stands in the city centre, with civic rooms behind its granite front. Harbour buildings face the working quays, and airport buildings face the apron and the car parks, and each one asks for a window that fits its own exposure.
The work starts with a walk round each opening, measuring the frame, the wall and the fixing points. The visit ends by naming the rating, the glazing and the frame for every window in a written specification. The first enquiry gets its written reply in one working day. The physical security in Aberdeen page lists the windows, doors and barriers in the city, and the blast resistant windows page lists the product range.
How a blast resistant window in Aberdeen holds its rating
A blast resistant window keeps its rating only as a whole set, never as a pane on its own. The glazing takes the pressure of the blast, the frame takes the load from the glazing, and the fixings pass that load into the wall. The specification names all three together, and the test proves all three together.
The glazing is a laminated build, with layers of glass bonded round an interlayer that holds the shards in place when the pane is struck. The frame is sized to the opening and to the weight of the glazing, with a depth that lets the rebate hold the pane under load. The fixings are set into the wall at spacings the test report allows, and the seal round the frame keeps weather out while the set stays true.
Some Aberdeen windows must open, and an opening window needs hinges and a handle that hold the same rating as the fixed set. The specification names the opening gear beside the frame and the glazing, so a window that opens is still one rated unit when it is shut.
A buyer weighing a glazed window against a solid door can read the blast doors glazed against solid guide, which lays out where light matters and where a solid leaf is the right call. The blast resistant windows guide to cost and specification breaks down the price of the work, from the rating to the frame and the fixings.
What the figures mean: blast, forced entry and fire
A buyer who weighs the glazing edges LPS 1175 Issue 8.2 (September 2024) edging the frame choice toward the grade that fits the opening. At SR1, the A1 grade allows one minute of attack. At SR2, the B3 grade allows three minutes. At SR3, the C5 grade allows five, and at SR4, the D10 grade allows ten. Those grades rate forced entry, and blast is a separate measure, so a window set can carry an LPS 1175 grade and a blast rating side by side.
Blast ratings sit on ISO 16933 for EXV and SB, and on EN 13123 and EN 13124 for EPR and EXR. Each class names a charge size and a distance, and the test proves the set against that charge. The blast ratings page lays out the classes and what each one asks of the window set.
A window set that must also stop a bullet takes its rating from EN 1522 with EN 1523, with classes running FB1 to FB7. The bullet resistant windows in Aberdeen page covers those sets, and the specification names the FB class beside the blast class so one set covers both threats.
When a window opens onto an escape route, the set needs a fire rating too. The fire rating uses class E, EW or EI. Each class of E, EW or EI holds its time, from 30 minutes to two hours. The classes and the minutes behind each one sit on the fire ratings page. Each window carries BS EN 1634-1:2014+A1:2018 as the standard behind its class, written on the specification beside the class itself. The fire rated windows cost factors guide breaks down the price of that work.
Martyn’s Law tiers reach a public building in Aberdeen. The tier turns on headcount: a site of 200 to 799 people is standard, and a site of 800 people and above is enhanced. What a site must do sits in the premises guide, and the Martyn’s Law standard gives the tier figures. Regulation falls to the Security Industry Authority, and the scheme is expected to open in spring 2027.
Aberdeen buildings and the window each one asks for
Five Aberdeen buildings are set beside the window each one asks for in the table below, with the reason behind the choice.
| Aberdeen building | Window asked for | Reason |
|---|---|---|
| Aberdeen Royal Infirmary | Laminated blast glazing in a rated frame | Wards need light, air and a held rating |
| University of Aberdeen laboratory | Glazed screen with a rated frame and fixings | Teaching rooms sit beside busy walkways |
| Robert Gordon University teaching block | Blast rated window set with a rated frame | Glazed walls face public routes |
| Harbour office | Blast rated windows at the quay side | Working quays face open water and traffic |
| Airport terminal building | Blast rated glazing at the entrance front | Public entrances face the apron and car parks |
The table follows the use of each building, so a ward asks for a different set from a harbour office. Drawings go to design in Aberdeen with the specification, and the windows on that specification are covered by security windows in Aberdeen. A solid door beside a glazed window sits on the blast resistant doors page, and the larger sites are covered by the enhanced tier physical measures guide.
From survey to fitted window
A survey opens the job, then a rating, then a written specification, then supply and install. The first visit walks each opening from frame to wall, taking the measure of the glazing, the fixings and the room use. The rating follows from what the building faces, and the specification then names the glazing and the frame, the fixings and the test for each window.
Lead times are set down on the programme. The lead times guide sets out where a rated set can hold a schedule back. Duties on the job sit with each party under the CDM 2015 duties guide.
Drawings travel with the enquiry, so the survey date can be fixed on the first reply.
Email [email protected] bringing the opening sizes and the frame sizes, with a note of the use of each room, and the reply sets out the Aberdeen scope and the next step.
Send the opening sizes with a note of the frame code for comfort Saffron Road, Romford, Essex RM5 3ES. Message immediately to fix the survey date, and carry the drawings to the visit.
Put the blast rating, the test report, the frame grade and the fire class on the order, and check each figure against the fitted window before sign off.
Questions Aberdeen buyers put about blast resistant windows
What blast rating does a window in Aberdeen need?
The rating follows from the threat the building faces, fixed at the survey and written into the specification. ISO 16933 gives EXV and SB, while EPR and EXR sit on EN 13123 and EN 13124. Each class is fixed to a charge size and a distance, and the survey fixes which class the opening must meet.
Must a blast resistant window carry a fire rating as well?
Yes. A blast rating and a fire rating can sit on one window set together. The set takes a fire rating in one of three classes, E, EW or EI, with the minutes running 30 to 120. The two figures sit on the same order, so one set covers the blast need and the fire need together.
Does an LPS 1175 grade cover blast?
No. The LPS 1175 grades rate forced entry, and the minutes run one, three, five and ten from SR1 to SR4. Blast is rated under ISO 16933 and EN 13123, and one window set can carry both figures.
How soon does the written quote for Aberdeen windows arrive?
The survey visit records each opening, the frame and the fixings, and the specification is drawn from that visit. The written reply goes out inside one working day.
Fit Aberdeen windows that hold their rating
Send over the opening sizes and how each room is used. The written quote names the glazing, the frame, the rating and the test for each window. Get a free quote
Other areas
Blast resistant windows in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.