Perimeter and HVM · PAS 68 and IWA 14-1

Security gates

Security gates UK: rated gates for pedestrian and vehicle entrances, with LPS 1175 forced entry and PAS 68 vehicle impact options across the UK.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed across the UK
Prefer to talk?+44 7352 267239

Get a free project quote

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Security gates control who drives and walks into a site. Rated versions resist forced entry to LPS 1175, vehicle impact to PAS 68, or both. Sliding, swing and bi-folding gates suit compounds, entrances and critical sites, and the rating must cover the gate, its posts and its foundations as one system.

  • LPS 1175 and PAS 68Forced entry and vehicle impact ratings
  • Sliding, swing, bi-foldingGate types for every opening
  • Automated optionsIntegrated with access control
  • Tested as installedFoundations and fixings included

What is a security gate

A security gate is the controlled point in a perimeter where vehicles or pedestrians enter. Unlike a barrier line, a gate must open on demand and still resist attack when closed. Rated gates carry test evidence for forced entry to LPS 1175, for vehicle impact to PAS 68 or IWA 14-1, or for both threats on one assembly. They sit within a perimeter and HVM scheme at the points where the barrier line must be passable.

Three arrangements cover most openings. Sliding gates suit wide vehicle entrances and are covered in detail on our sliding vehicle gates page. Swing gates suit narrower openings with room for the leaf to arc. Bi-folding gates fold back in sections where side space is limited. The vehicle impact ratings guide and the LPS 1175 guide explain the two rating systems.

Choosing the right rating for security gates

Rate the gate for every threat at that entrance. A vehicle entrance on a public road needs impact resistance; a compound gate also needs forced entry resistance for when it stands closed and unattended.

Gate duty Rating to ask for Typical use
Forced entry LPS 1175, for example SR2 (B3) or SR3 (C5) Compounds, yards and side entrances
Vehicle impact PAS 68 with vehicle mass and speed Entrances on vehicle approaches
Dual rated LPS 1175 and PAS 68 on one assembly Critical sites with both threats
Pedestrian gates LPS 1175 to suit the site rating Staff and visitor side entrances

ISO 22343-1:2023 is the current international crash standard. PAS 68 vs IWA 14 vs ISO 22343 explained shows how the three relate and how to read a rating.

Where the entrance must also stop a vehicle, ordinary gates are not enough. Our guide to anti-ram gates and barriers compares sliding gates, swing gates, bollards and road blockers.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

How security gates are built

A rated gate starts with a frame sized for the opening, infilled with mesh, bars or solid plate to suit the threat and the setting. Locking holds the leaf against forced entry, and the hinges, track or rollers carry the leaf’s weight through long daily use. Vehicle gates need foundations designed for both the impact load and the automation.

Automation adds a motor, safety devices and integration with the site’s access control: readers, intercoms or automatic number plate recognition. Power and drainage are planned before the civil work starts, because retrofitting them under a finished gate is costly.

Rate the gate for both threats. A gate that stops a ram but opens to a screwdriver fails the site. Where both threats exist, ask for LPS 1175 and PAS 68 evidence on the same assembly.

Combining gates with other ratings

Pedestrian lanes beside a vehicle gate can use turnstiles or security portals so people do not tailgate vehicles. Guard houses and gatehouses take security doors rated to LPS 1175. Where the gatehouse also needs fire separation, fire and security doors combine both ratings in one assembly.

Where security gates are used

Utilities and energy sites gate substations, treatment works and depots. Data centres control every vehicle that enters the compound. Government and defence estates gate perimeters and secure zones, and transport hubs separate service yards from public areas.

School boundaries use pedestrian and vehicle gates side by side, as security doors and gates for schools explains.

What affects the cost and lead time of security gates

The width of the opening and the chosen arrangement set the steelwork scope. Automation adds motors, safety devices and controls, and integration with access control needs coordination with the site’s security systems. Foundations for impact rated gates involve serious civil work. Finish, such as powder coating to a site colour, and any listed setting add time. No prices are given here because every entrance differs.

Gates live outdoors and the finish decides how long they last. Our guide comparing powder coating, galvanising and paint covers durability, repairs and duplex systems.

Range and models

The gate range has 15 numbered designs. Models 01 to 14 are LPS 1175 SR2 gates and model 15 is a PAS 24 gate. Each model number is a standard layout in the range, so you can quote it exactly when you send the quote form. The drawings are indicative: they show where the panels sit, and the final panel sizes, glazing, finish and hardware are confirmed in the specification. Colour, infill spacing and automation are agreed at specification stage.

Drawings of security gate models LPS1175-SR2-01-GATE to LPS1175-SR2-08-GATE
Gate models LPS1175-SR2-01-GATE to LPS1175-SR2-08-GATE
Drawings of security gate models LPS1175-SR2-09-GATE to LPS1175-SR2-14-GATE and PAS24-15-GATE
Gate models LPS1175-SR2-09-GATE to LPS1175-SR2-14-GATE and PAS24-15-GATE
Model Doors Layout
LPS1175-SR2-01-GATE Gate 36 vertical bars
LPS1175-SR2-02-GATE Gate 20 vertical bars
LPS1175-SR2-03-GATE Gate 18 vertical bars
LPS1175-SR2-04-GATE Gate 22 vertical bars
LPS1175-SR2-05-GATE Gate 26 vertical bars
LPS1175-SR2-06-GATE Gate 28 vertical bars
LPS1175-SR2-07-GATE Gate 24 vertical bars
LPS1175-SR2-08-GATE Gate 26 vertical bars
LPS1175-SR2-09-GATE Gate Mesh infill
LPS1175-SR2-10-GATE Gate 14 vertical bars with centre rail
LPS1175-SR2-11-GATE Gate 16 vertical bars
LPS1175-SR2-12-GATE Gate 12 vertical bars
LPS1175-SR2-13-GATE Gate 10 vertical bars with centre rail
LPS1175-SR2-14-GATE Gate 13 vertical bars
PAS24-15-GATE Gate 19 vertical bars

How to specify security gates

  1. Define the threats. Forced entry, vehicle impact, or both at this entrance.
  2. Choose the arrangement. Sliding, swing or bi-folding to suit the space.
  3. Set the ratings. Name the LPS 1175 and ISO 22343-1:2023 ratings required.
  4. Plan power and drainage. Get supplies in place before the ground works begin.
  5. Integrate access control. Coordinate readers and intercoms with site systems.
  6. Check the evidence. Ask for proof naming every standard and rating.

Shallow-mount units trade depth for services coordination. See how to choose HVM bollards for the full comparison.

Security gate FAQs

Can one gate carry both LPS 1175 and PAS 68 ratings?

Yes. Dual rated assemblies are tested for forced entry and for vehicle impact, and the evidence must name both ratings. Ask for both test reports before you accept the gate as dual rated.

How is pedestrian safety handled?

Automated gates carry safety devices that stop or reverse the leaf if a person is in its path. The safety design follows the gate’s risk assessment, and pedestrian routes are kept separate from the leaf’s travel wherever possible.

What power does an automated gate need?

A dedicated electrical supply, planned before the civil work. The exact requirement depends on the motor and the site’s access control, so coordinate the supply with the gate design early.

What maintenance does a gate need?

Moving parts, locks and safety devices need periodic checks and adjustment. Our maintenance service, done by our own team or by our installation partners, covers automated and rated gates, including their access control interfaces.

Can the gate match our existing fencing?

Infill, mesh pattern and finish are coordinated with the existing perimeter so the gate reads as part of the fence line. The rating is unaffected as long as the tested construction is kept.

Specifying a rated entrance?Send your opening sizes and threat assessment and we will propose a gate arrangement with the right ratings.
Get a free quote

Where we supply security gates

Pick your area to read how security gates are specified there, from the vehicle or pedestrian rating to the site details that decide the gate.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.