Certified physical security

ArxBridge
Canalside offices with a navy steel entrance door in Birmingham

Security · LPS 1175 SR2 to SR5

Turnstiles in Birmingham

Turnstiles for Birmingham stations, shops, campuses and hospitals, with full-height and glass lanes, readers and side gates set to each entry.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Birmingham
Prefer to talk?+44 7352 267239

Get a free quote in Birmingham

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Birmingham

What we supply in Birmingham

More on this

A Birmingham entry lane lets one person through at a time. Lanes stand at staff entries off the New Street concourse, at service entries in the Bullring, and where Grand Central retail staff pass from the public floor to the rooms behind it. Each lane counts the person who passes and holds the line shut when the lane is closed.

A turnstile for a Birmingham campus, hospital or shop is picked by the entry it guards. A full-height lane suits an entry with no staff beside it, a glass lane suits a reception where the entry should look open, and a waist-height lane suits a staff entry with steady flow. The lane, the reader and the side gate are settled as one set, and the width follows the flow rather than the size of the room.

The choice starts with the lane itself: the width, the flow at busy times, the reader, and the side gate beside it. Birmingham’s wider picture is on its area page, physical security in Birmingham.

One person at a timeEach lane passes a single person
Full height and glassTall lanes and clear glass lanes
Readers and side gatesCard readers and a gate for access needs
Flow and countingLanes that count each person through

Birmingham entries that need a turnstile lane

Staff entries off the New Street concourse need lanes that work with no one watching them. A full-height lane turns only for a person with a valid pass, and the lane holds shut for anyone else. The security turnstiles guide sets out the lane types in full.

Service entries at the Bullring and Grand Central take goods, trolleys and staff through the same doors, so the lane there sits beside a wider gate for goods. Shops and their frontages are on the retail sector page, and the three entry types sit side by side in the turnstile, speed gate and portal compared guide.

Campus buildings at the University of Birmingham see students move between lectures all day, and a lane there must pass a crowd in waves and still count each person. Reading rooms at the Library of Birmingham take a glass lane that keeps the entry looking open, and staff entries at Queen Elizabeth Hospital take lanes that work through the night. University entries sit on the education sector page, and hospital entries sit on the healthcare sector page.

Lane types and grades for a Birmingham entry

A full-height lane suits an entry with no staff beside it, since the tall barrier leaves no way over the top. A glass lane suits a reception, where clear leaves keep the entry looking open while the lane still counts each person. A waist-height lane suits a staff entry with steady flow, where speed matters more than height. Full-height and glass lanes in full are on the full height glass turnstiles page.

The lane schedule completes LPS 1175 Issue 8.2 (September 2024) completing the grade record for the doors and grilles beside each lane. Every grade appears on the LPS 1175 standard page. SR1, class A1, gives one minute. SR2, class B3, gives three minutes. SR3, class C5, gives five minutes. SR4, class D10, gives ten minutes. The three higher grades are set beside each other in the SR2, SR3 and SR4 compared guide.

A site that also runs vehicle barriers follows a different line for the vehicle side. The HVM standards guide sets out the change. On 25 October 2023, PAS 68:2013 came to an end, and the current vehicle barrier standard became ISO 22343-1:2023. The current classes are on the vehicle impact ratings page. Under BS 8300 and Approved Document M, a side gate should open with less than 30 N across the first 30 degrees, with the force after that under 22.5 N, and the Approved Document M guide gives the access duties in full.

The table below starts with five Birmingham entries, and the survey plus the entry assessment fix the lane and the door grade that go on the final schedule for each entry.

Entry in Birmingham Lane build Reader Door grade beside the lane
Library entry, Library of Birmingham Glass lane, clear leaves Card reader SR1, class A1
Staff entry, New Street station Full-height lane Card reader SR2, class B3
Service entry, Bullring Full-height lane Card reader SR2, class B3
Campus entry, University of Birmingham Waist-height lane Card reader SR1, class A1
Staff entry, Queen Elizabeth Hospital Glass lane, clear leaves Card reader SR2, class B3
Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Picking the lane, reader and side gate

Start with the entry: count the lanes the flow needs, note the width each lane must pass, and mark where the reader sits. A lane that faces a crowd at peak times and a lane that serves a quiet office floor take different builds, and the costs that shift a lane price are named in the turnstile cost factors guide.

Lane, reader and side gate are settled as one choice. A card reader suits a staff lane, a QR reader suits a visitor lane, and the side gate beside the lanes takes a push bar and a lock that holds the gate shut when the power is off. Each lane should come with a reader bracket and a cable route set out on the drawing. The access control doors guide gives reader and lock choices in full.

Locks and access finish the choice. The panic hardware guide gives the hardware for a gate that must open fast in an emergency, and the lockdown hardware guide gives the hardware for a lane that must lock down fast. The start expected for Martyn’s Law is spring 2027. The standard tier is for places with 200 to 799 people. The enhanced tier is for places with 800 people or more. Each tier’s duties appear in a list on the Martyn’s Law standard page.

Looking over a Birmingham entry and drawing the lane list

A person measures each entry on site before any lane is ordered. The width of each lane is taken at the floor, the reader position is noted, and the cable route from the reader to the control point is marked on the plan. Notes and photographs from that visit go into the file behind the lane list, and any figure that looks shaky is checked again on a second visit. Checks to run on a lane in daily use are on the security door maintenance checklist page.

Survey notes and drawings from each entry stay in our Birmingham archway Saffron Road, Romford, Essex RM5 3ES. Email early after the survey and the lane list goes on its drawing.

Send the lane count and the lane width to [email protected] by tuesday, and the reply names the lane list for each entry inside one working day.

Final checks ahead of a Birmingham turnstile order

Count the lanes against the flow at busy times before the order goes in. A site that queues at peak times needs another lane, since a lane passes one person at a time and the queue grows behind it.

Look over the lane list again before the order goes in, with width, build, reader and door grade beside each lane, and each side gate beside its lanes. Checks to run when the lane reaches the site are in the acceptance and snagging guide, and the cover for parts that wear out is held in the warranty, defects and guarantees guide.

Any figure waits until the survey ends and the lane list is set, since one width of lane can take readers of different types. The figure follows the lane count, the lane build and the reader type. What moves the figure, from the lane count to the reader type, is shown in the turnstile cost factors guide.

Birmingham buyers ask about turnstiles

Does a turnstile slow the morning rush at New Street?

A lane passes one person at a time, so the count of lanes follows the flow at busy times. A site that queues at peak times adds a lane rather than widening one.

What is the difference between a turnstile and a speed gate?

A turnstile turns an arm or a leaf to pass one person, while a speed gate opens glass leaves and shuts them behind the person. The turnstile, speed gate and portal compared guide sets the three apart.

Can a wheelchair user pass a turnstile lane?

A wheelchair user passes through the side gate beside the lanes, not through a lane. The gate is set wide enough for access needs, and its opening force stays under the limits that BS 8300 and Approved Document M set.

What upkeep does a turnstile need in daily use?

Care starts with a yearly visit. The visit looks at the arms first, then the leaves, then the reader and the lock, and a worn part is swapped before the lane stops. Moving parts are cleaned and oiled in the way the maker asks, and a leaf that has moved is changed before it sticks.

Turnstiles for a Birmingham building?

Share the lane count and the width of each lane, and lanes, readers and side gates are priced as one figure. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.