Certified physical security

ArxBridge
Glass and brick offices with steel entrance doors and bollards in London

Security · LPS 1175 SR2 to SR5

Turnstiles in London

Turnstiles in London for stations, offices, campuses and hospitals, with full height and glass lanes, ratings and access control matched to each entrance.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in London
Prefer to talk?+44 7352 267239

Get a free quote in London

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in London

What we supply in London

More on this

Waterloo, London Bridge and Victoria move travellers through their concourses from the first train to the last, and the City of London and Canary Wharf move office staff through lobbies at the same hours. University College London guards lecture rooms, libraries and halls across central campuses, while King’s College London guards its own lecture rooms and libraries, and Guy’s Hospital and St Thomas’ Hospital keep wards and departments open day and night.

A turnstile guards that flow with a cabinet, a barrier and a reader at each lane, and the lane type follows the crowd at that entrance, not how big the lobby is. A full height lane suits a station gate line where no one passes without a ticket, a glass lane suits an office lobby where staff pass in a steady stream, and a waist high lane suits a campus entrance where students pass in waves. The full height glass turnstiles page gives the tall form in full.

Offices, stations, campuses and hospitals across London ask for the same three parts, and each building type shapes the lane in its own way. A station lane clears a queue fast then holds shut through the night, an office lane takes staff through in a morning rush, and a hospital lane lets visitors pass with a pass from reception. London as a whole has its own page: physical security in London.

London stationsWaterloo, London Bridge and Victoria
Lane typesFull height, glass and waist high
Access at each laneCards, readers and intercoms
Rated cabinetsSR grades on tested cabinets

London buildings that put turnstiles to work

Waterloo leads the city on turnstile duty. Its gate lines take travellers through in waves before each departure, and the lanes must move a queue fast then stay shut after the last train. London Bridge and Victoria face the same rhythm, with commuters arriving by train and on foot and staff passing through side gates beside the main lanes. The lanes there take their grade from the risk at each entrance.

The City of London and Canary Wharf put glass lanes in office lobbies, where staff pass in a morning rush and visitors wait at a desk for a pass. A reader at each lane takes a staff card, and an intercom at the desk lets reception open a lane for a guest. The public spaces page covers busy entrances in the open, and the retail sector page looks at shop fronts and mall frontages.

King’s College London guards campus entrances where students, staff and delivery vans pass through the same gates, and University College London guards entrances of the same kind, while Guy’s Hospital and St Thomas’ Hospital guard entrances where patients, visitors and ambulances arrive at all hours. The education sector page looks at campus perimeters, and the healthcare sector page looks at hospital boundaries.

Grades and classes behind a London turnstile

A turnstile lane builds LPS 1175 Issue 8.2 (September 2024) building the cabinet, barrier and reader as one tested unit, and each entrance takes the grade its risk asks for. The grades step up in time: one minute at SR1 and A1, three minutes at SR2 and B3, five minutes at SR3 and C5, ten minutes at SR4 and D10. The LPS 1175 standard page gives the four grades in full. The ratings compared guide weighs forced entry, blast and ballistic against each other for one lane.

Five London entrances open the table below, with one lane build and one grade beside each.

Entrance in London Lane build LPS 1175 grade Reader and access
Station lane, Waterloo Full height cabinet, flap barrier SR2, class B3 Card reader beside each lane
Office lobby lane, City of London Glass turnstile, optical sensors SR2, class B3 Reader and intercom at the desk
Campus entrance, University College London Waist high turnstile, tripod barrier SR1, class A1 Student card reader on each lane
Hospital entrance, Guy’s Hospital Glass turnstile, flap barrier SR2, class B3 Visitor pass reader at reception
Office lobby lane, Canary Wharf Full height cabinet, flap barrier SR3, class C5 Card reader and intercom at each lane

A gate beside each lane gives step free access. The gate beside the lane takes its opening force from BS 8300 and Approved Document M. Force at the gate stays under 30 N of push while the gate swings through its first 30 degrees, with 22.5 N after that point. The security turnstiles guide covers the lane types in full.

The Martyn’s Law standard page lists the duties for each tier. Spring 2027 should bring the start of Martyn’s Law. Capacity puts a place in its tier: the enhanced tier holds places of 800 people or more; the standard tier holds places of 200 to 799 people.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Setting out a London turnstile lane

Start with the lane width: measure the clear width between the cabinets, check the floor levels on both sides, and find where power sits for the readers. A station lane busy all day and an office lane shut through the night need different barriers, and the turnstile versus speed gate versus portal page sets the three forms side by side.

Barrier, cabinet and reader make one settled choice. A glass barrier suits a lobby where staff see who walks in, while a full height cabinet suits a gate line where no one passes without a check, and the fixings must suit the cabinet, since a barrier that beats its cabinet still takes no rating.

Each lane takes readers and an intercom suited to its daily flow, and a lane closed overnight needs a lock that stays shut with no power.

Survey notes that fix each London lane

Each lane is measured where it stands, with width, floor build and power points noted, and the people through the entrance are counted at busy hours before the schedule is drawn up.

Lane notes stay at our London pantry Saffron Road, Romford, Essex RM5 3ES. Email today with the lane width and the busy hour flow, so the class and the drawing stay filed together.

Write to [email protected] to check the lane width, barrier type and reader position for each entrance, and the office answers in writing within one working day.

Final checks before a London turnstile opens

Before the grade is fixed, look at the floor beside each lane. A cabinet set on uneven stone or a barrier that catches a bag strap slows the lane down, so the floor level beside the opening shapes the barrier choice.

Check the schedule a second time before the order goes in, lane by lane, and check width, grade, barrier and reader against the survey notes. The checks for a lane on arrival are in the acceptance and snagging guide. Worn parts in daily use are covered on the warranty, defects and guarantees guide.

Price follows the lane count, the barrier type and the reader at each lane. The turnstile cost factors guide shows what shifts the figure, from the width of the lane to the type of barrier.

London buyers ask about turnstiles

Which turnstile suits a busy station concourse?

A full height lane suits a station concourse, since no one passes without a check and the cabinet holds the line through the rush. A glass lane suits an office lobby with a steady stream, where staff pass in order.

Can a turnstile grade prove it stops a vehicle?

A forced entry grade covers the cabinet and barrier alone, and a vehicle rating covers the line alone, so a lane facing both duties carries both ratings on its schedule.

What sits beside a turnstile for step free access?

A gate beside the lane gives step free access. Its lock and closer are set for the same daily flow as the lane, and its swing stays clear of the readers.

How is a turnstile looked after in daily use?

A booked visit opens the upkeep routine. The cabinets and barriers are checked first, then the readers and locks, and worn parts are changed before they stop working. The security door maintenance checklist page holds the checks a lane needs in daily use.

Turnstiles for a site in London?

Share the lane width, barrier type and reader position for each entrance, and the quote covers cabinet, barrier and readers in one figure. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.