Certified physical security

ArxBridge
Harbourside converted buildings with steel entrance doors in Bristol

Security · LPS 1175 SR2 to SR5

Turnstiles in Bristol

Turnstiles in Bristol for stations, stadiums, offices and campuses, with waist height, full height and glass lanes, access control and a written quote.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Bristol
Prefer to talk?+44 7352 267239

Get a free quote in Bristol

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Bristol

What we supply in Bristol

More on this

An entrance in Bristol that takes a crowd needs a lane that admits one person at a time and bars the next person from riding on the same read. Turnstiles at a station gateline, a stadium gate, an office reception or a campus entrance carry that job through the day, and the lane type sets the speed of the queue and the effort needed to pass without a read. The right lane follows from the people who use the entrance and the peak they arrive in, not from the lane alone.

Bristol Temple Meads sends rail passengers through its gatelines in the morning and evening peaks, while Cabot Circus pulls shoppers through retail entrances across the day. Students pass through the gates of the University of Bristol and its halls, staff and visitors enter Bristol Royal Infirmary through hospital entrances, and crowds arrive at Ashton Gate on match days. Aerospace works at Filton and offices beside the harbourside take staff through reception lanes each morning, and every one of these entrances has its own flow, its own peak and its own risk.

The survey measures each opening, notes the floor level, maps the queue space, fixes the reader height and checks the escape route beside the lanes. Those notes shape a written specification listing the lane type, the reader, the height and the finish at every entrance, and the order is built from that document. Turnstiles in Bristol sit beside doors, gates, barriers and shutters, and the physical security in Bristol page lists the city range in one place.

Lane typesWaist height, full height and glass lanes that pass one person at a time
AccessCard, fob or ticket reader fixed at hand height on each lane
EgressRelease beside each lane that frees the way out on alarm
ReplyWritten answer inside one working day

Lanes for a gateline, a gate and a reception desk

A waist height lane belongs at an office reception where staff arrive in a steady stream and a member of staff watches the door. A single person passes on each read, the arm turning and locking at once so nobody else slips through, and the open frame keeps the reception light and easy to watch. The security turnstiles guide sets out where each lane type belongs and what to check before choosing.

A full height lane belongs at a ground entrance or a yard gate where climbing over must be stopped. The cage turns through a full circle, so entry needs a valid read before the cage turns, and the cage blocks tailgating at the gate. Glass full height lanes give the same hold with a clear sightline through the lane, which helps staff at a busy gate watch the far side.

A glass optical lane fits a corporate reception that wants a clear sightline and a quiet look. No arm turns, so the lane relies on sensors and a glass barrier that closes when a read fails, and the lane reads well where the flow is steady rather than surging. The guide on turnstile versus speed gate versus portal weighs each option against the flow at the door, while the turnstile cost factors guide lists what goes into the written quote.

The grade behind the lane

The LPS 1175 scale spans A1 to H20, and the letter and number mark how long a lane resists a forced entry test with a stated tool set. SR1 marks one minute, SR2 marks three, SR3 marks five and SR4 marks ten, and a higher grade buys more delay at a gate that faces a determined attack. The delay a full height lane gives exceeds LPS 1175 Issue 8.2 (September 2024) exceeding the delay of a waist height lane at the same entrance, so the grade is chosen against the threat at that gate rather than against the lane alone.

EN 1627 sets resistance classes for windows, doors and shutters, and those classes sit beside the LPS grades in a specification rather than replacing them. The two scales test different things, so a buyer who mixes them in one line invites a wrong comparison. The guide LPS 1175 versus EN 1627 sets out how the two scales differ and which one to cite for a lane.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Readers, tickets and the queue at peak times

Who passes is the reader’s call. The reader sits where the hand falls naturally and takes a card, a fob or a ticket, and the lane only opens on a valid read, so a reader mounted above hand height or set back from the arm holds up each person at the lane. The survey fixes the reader height against the flow of people, and a second reader on the exit side keeps the lane moving both ways where the site needs it.

At Bristol Temple Meads the gateline must clear a train load in minutes, so the lane count follows the peak flow rather than the average. The transport hub security requirements guide covers what a station entrance needs, and access control doors covers the readers and releases that sit beside the lanes. Where a fast lane matters more than a cage, pedestrian speed gates give a quicker pass with a lighter hold.

Fire, escape and the rules for a busy place

Every lane needs a way out when the alarm sounds. The release at each lane frees the way out, and the escape route is kept clear of queue rails and signs so people can leave without hunting for the exit. A turnstile that holds people in during a fire fails the entrance, whatever its grade, so the release is tested as part of the survey rather than left to handover day.

Where a lane sits in a fire rated wall, the door or shutter beside it carries a fire rating, with classes E, EW and EI, in a band from 30 minutes to two hours. The bands follow BS EN 1634-1. The fire ratings page lists each band and what it means for the opening. Spring 2027 remains the planned start for Martyn’s Law. The Security Industry Authority is named as regulator, with the tiers drawn at 200 to 799 people for standard premises and 800 or more for enhanced. Martyn’s Law guide for premises explains what a venue must have in place, and the tiers are laid out on the Martyn’s Law page.

Pick the lane from the peak flow and the threat at the gate, then check the grade, the reader height and the escape route before the order is placed.

Lane choice at a glance

Lane Where it fits What to check
Waist height Office reception, campus entrance Arm height, reader height, queue space
Full height Stadium gate, yard entrance Cage size, climb resistance, escape route
Glass optical Corporate reception, quiet lobby Sensor line, barrier close, sightline

The table is a starting point, not a verdict. The survey fixes the lane for each entrance from the flow, the threat and the space beside the lane, and a lane that looks right on paper can fail where the queue has nowhere to stand.

From survey to a written quote

The job runs in stages. The survey measures the openings and the flow, the specification names the lane, the grade and the reader for each entrance, and the written quote follows from that document. The same lane range is set out for other cities, such as turnstiles in Birmingham, and the Bristol survey follows the same stages.

Post the site plan, the gate count and the measured openings to the coast Saffron Road, Romford, Essex RM5 3ES. Phone immediately when the plan is posted, and a survey date can be set while you are on the line.

Email [email protected] about openings, the lane count and the reader type for each entrance, and the written reply names the Bristol scope and the step that follows. The written reply is back inside one working day.

Which lane fits Bristol Temple Meads at peak times?

Waist height lanes in a row suit a station gateline, because each arm turns fast for one person and the row clears a train load in minutes. The lane count follows the peak flow, and the survey checks the queue space beside the gateline before the count is fixed.

Do turnstiles at Ashton Gate need full height lanes?

Full height lanes suit the outer gates of a stadium, where climbing over must be stopped and tailgating must be blocked. Waist height lanes suit staffed entrances inside the ground, and the lane for each gate is fixed at the survey.

What grade should a Bristol office ask for?

A reception lane often takes SR1, while a gate that faces a higher threat takes a higher grade up the run to SR4. The grade follows the threat at that entrance, and each lane’s grade is written into the specification so the order can be checked against it.

Can a turnstile lane stay open for step free access?

No, each lane admits a single person at a time, so step free access runs beside the lanes as a wide gate on its own. The survey measures that route for width and level, checking it against BS 8300 and Approved Document M, then lists the gate in the specification with the lanes.

Ask for turnstiles for your Bristol site

Send the measured opening widths and the lane count for every entrance. The written quote names each lane, each reader and the fitting work for every entrance. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.