Certified physical security

ArxBridge
Sandstone and glass offices with a steel entrance door in Leeds

Security · LPS 1175 SR2 to SR5

Turnstiles in Leeds

Turnstiles in Leeds for stations, stadiums, offices and campuses, with full height and waist height lanes, access control and a written quote.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Leeds
Prefer to talk?+44 7352 267239

Get a free quote in Leeds

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Leeds

What we supply in Leeds

More on this

A buyer in Leeds who needs to control who passes an entrance starts with the flow of people through it, because a lane that suits a quiet office fails at a stadium gate. Turnstiles in Leeds cover waist height lanes, full height lanes and glass lanes that let one person through at a time, each lane paired with a reader, a barrier arm and a release that fits the building. The lane, the reader and the release work as one set, and the wrong lane at a busy entrance holds the queue back.

Passengers move through the gates of Leeds station at all hours, and shoppers come through the entrances of Trinity Leeds on Briggate. Buildings beside the University of Leeds hold the students of Leeds Beckett University, and each morning South Bank offices and city centre civic buildings take staff and visitors through reception lanes. On match days, crowds move through the turnstiles at Elland Road and Headingley Stadium in waves.

A survey records the opening width, the floor level, the queue space, the reader position and the escape route beside each lane. The specification that follows names the lane type, the height, the reader and the finish for every entrance. That written specification is what the order for turnstiles in Leeds is built on. Doors, gates, barriers and shutters across the wider range sit on the physical security in Leeds page.

LaneWaist height, full height and glass lanes for one person at a time
ReaderCard, fob or ticket reader paired with each lane
ReleaseFail safe release on the escape route beside the lanes
ReplyWritten answer in one working day

Waist height, full height and glass lanes at a Leeds entrance

A waist height lane fits an office reception with staff passing in a steady stream while a member of staff watches the entrance. One person passes as the arm turns, then it locks, and nobody else can slip through on that read. The lane is open and light, and the reception desk beside it keeps the entrance clear. Lane types and the places each one fits are covered in the security turnstiles guide.

A full height lane suits a stadium gate or a yard entrance where no one should climb over. The lane turns through a full cage, so a person passes only after a valid read, and the cage stops tailgating at the gate. Full height glass turnstiles give the same control with a clear view through the lane. Where a turnstile fits, and where a speed gate or a portal serves better, is shown in the guide turnstile versus speed gate versus portal.

The reader decides who passes. A card, a fob or a ticket reader sits at hand height on each lane, and the lane opens only after a valid read. A reader that sits too high or too far from the arm slows every person through the lane, so the survey fixes the reader position against the flow of people. The guide turnstile cost factors names the parts behind the written quote: lane, reader and release together.

Ratings that fit a turnstile lane: LPS 1175, fire and the escape route

A lane that guards a busy entrance features LPS 1175 Issue 8.2 (September 2024) featuring the forced entry grade beside the lane width in the written specification. A1 to H20 is the run of LPS 1175 grades. SR1 and A1 give one minute, SR2 and B3 give three, SR3 and C5 give five, and SR4 and D10 give ten, with the lightest tool set at one minute and the heaviest at ten. Check the order against the grade table on the LPS 1175 standard page.

The grade matters where the lane is the only barrier at an entrance, because a lane that resists a push must also resist tools for the time the grade names. A waist height lane in a staffed reception takes a lower grade than a full height lane at an unstaffed yard gate, and the survey fixes which grade each lane takes.

Every lane needs a clear escape route. When the alarm sounds, the release beside the lanes has to let people out fast, and the specification names the fire class of the doors beside the lanes. Beside the lanes, a fire rated door set carries a class of E, EW or EI, from 30 minutes to 120, with every band listed on the fire ratings page. Order lane, release and fire door together as one set, and the escape route gets its check before the order goes in.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Leeds sites and the lane each entrance needs

Leeds site Lane Site notes
Leeds station Waist height lanes at the gateline Passengers pass the gates at all hours and the lanes stay clear for the next train
Trinity Leeds Glass lanes at the service entrances Staff pass through in the morning and the lanes keep shoppers out of the service areas
University of Leeds Waist height lanes at the library entrance Students pass the lanes through the teaching day and the reader sits at hand height
South Bank offices Glass lanes in the reception Staff and visitors pass the desk each morning and the lanes suit the light reception
Headingley Stadium Full height lanes at the gates Match-day crowds move through in waves and the lanes stop tailgating at the gate

Five Leeds sites sit in the table above, each joined to its lane and to the reason that lane fits the entrance. Birmingham covers the same lane in the next city on turnstiles in Birmingham, while the vehicle gate beside the pedestrian lanes sits on security gates in Leeds.

Martyn’s Law and the two tiers in Leeds

Which of the two tiers a premises sits in comes down to its headcount. A premises with a headcount between 200 and 799 people belongs to the standard tier. From 800 people up, the enhanced tier applies to the premises. The Security Industry Authority will regulate the law, which is due to start in spring 2027. The law covers stations, shopping centres and stadiums, and a large university building can fall under it as well. Each tier’s duties appear in the Martyn’s Law guide; the guide to enhanced tier physical measures sets out the physical measures for the larger tier, with the tier figures listed in the Martyn’s Law standard.

Because it slows entry and hands staff a point of control, a turnstile lane counts among the physical measures an enhanced tier premises can use. The standard tier calls for procedures staff can follow, while the enhanced tier calls for physical measures too. One lane alone cannot meet a tier’s duties, so lane and procedures go on separate lines of the specification.

Survey, specification and fitting

The job moves from first visit to fitted lane through five stages: survey, rating, written specification, then supply, then fitting. The survey measures every opening, and the notes take down the width, the floor level, the queue space, the reader position and the escape route beside it. Lane type, height, reader, release and finish each get a line in the specification. The specification gains a line of its own for any new reader or release.

Email [email protected] to note the opening sizes, the lane count and the access control reader for each lane. The written reply names the Leeds scope and the order of the next steps. Doors beside the lanes sit on Security doors in Leeds, and the Birmingham page linked above covers the same lane in another city.

Send the entrance drawings, the lane count and the opening widths to the clinic Saffron Road, Romford, Essex RM5 3ES. Text first once the opening widths are to hand, and the survey visit can be fixed on that same call.

Put the lane type, the forced entry grade and the escape release in writing before ordering, then match each one to the lane as fitted.

Leeds buyers ask about turnstiles

What lane fits Leeds station when crowds peak?

A waist height lane suits a gateline where passengers pass in a steady stream, because the arm turns fast for one person and locks at once. The reader sits at hand height on each lane, and the queue space beside the lanes is measured on the survey.

Do turnstiles at Elland Road need full height lanes?

A full height lane suits a stadium gate where no one should climb over, because the cage stops tailgating at the gate. A waist height lane suits a staffed entrance inside the ground, and the survey fixes which lane each gate takes.

How does a turnstile lane work with a fire alarm?

The release beside the lanes lets people out fast when the alarm sounds, and the fire class of the doors beside the lanes is named on the specification. The lane, the release and the fire door are ordered as one set.

When will the written quote for Leeds turnstiles arrive?

The survey records the openings, the lane count and the readers, and the specification comes out of that visit. The written reply reaches you in one working day.

Plan the turnstiles for your Leeds entrance

Send the opening widths with the lane count for each entrance. The written quote sets out the lane, its reader and the fitting for each entrance. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.