Security · LPS 1175 SR2 to SR5
Security windows in Birmingham
Security windows for Birmingham stations, shops, hospitals and universities, with EN 1627 classes and glazing matched to each opening on site.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Birmingham
Get a free quote in Birmingham
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Birmingham
What we supply in Birmingham
Glass fills the front of Birmingham. New Street station sets wide panes beside its concourse doors, the Bullring lines its shop fronts with glass from pavement to fascia, and Grand Central adds more shop glass under the station roof. Each pane lets daylight in and lets people inside see the street, and each pane also stands between those people and a hand that tries the frame.
A security window for a Birmingham ward, lecture room or shop is picked by the room it guards. A ward at Queen Elizabeth Hospital needs a pane that dims the light and a lock a nurse can work at night, a lecture room at the University of Birmingham needs a pane that takes daily use from students, and a reading room at the Library of Birmingham needs a clear pane that keeps the room bright. Frame, glass and fixings are proved as one set, and the opening sets the class, not the size of the pane.
The choice starts with the opening: its width and height, the wall round it, and the way the light opens. A fixed pane fits a shop front watched by staff through the day, a pane that opens fits a ward that needs fresh air, and a barred pane fits a store room where no view is needed. The wider picture for the city is on the Birmingham area page, physical security in Birmingham.
Where Birmingham glass works hardest
Glass on the New Street station concourse sits beside doors in use all day, with travellers crossing both ways past the panes. A pane there needs a clear view for staff who watch the crowd. Station glass duties are set out in the transport hub security requirements guide.
Shop fronts at the Bullring and Grand Central stand open to shoppers all day, with goods behind the glass. A laminated pane keeps the goods in view and stays in its frame after a blow, while the frame takes the load the pane passes on. The retail sector page holds shops and their frontages, and bars for lights with no view are in the window security bars guide.
Lecture rooms and libraries at the University of Birmingham fill with students between classes, and the glass looks onto courtyards where students gather. Reading rooms at the Library of Birmingham need clear panes for daylight, and ward windows at Queen Elizabeth Hospital sit beside beds where patients rest at night. Ward and department glazing is on the healthcare sector page, school and university glass is on the education sector page, and classroom glass in full is in the security windows for schools guide.
Classes and grades behind a Birmingham window
The schedule collects LPS 1175 Issue 8.2 (September 2024) collecting the four grades beside each opening: SR1 and A1, SR2 and B3, SR3 and C5, SR4 and D10. SR1, class A1, stands for one minute, SR2, class B3, stands for three minutes, SR3, class C5, stands for five minutes, and SR4, class D10, stands for ten minutes. Every grade is held on the LPS 1175 standard page. The three higher grades sit side by side, as the guide comparing SR2, SR3 and SR4 shows.
BS EN 1627:2021 is the current edition. The six classes run RC1 to RC6, RC1 lightest and RC6 heaviest, and the class follows the tool set the window must meet and the time it must meet it for. The two families sit side by side in the LPS 1175 versus EN 1627 guide, and forced entry, blast and ballistic sit together for one window on the ratings compared page.
Frames and glazing take FB1 to FB7, rated under EN 1522 and EN 1523. EN 1063 gives BR1 to BR7 for glass alone, and SG1 and SG2 sit beside the BR scale for shotgun threats. LPS 1270 Issue 1.1 (2014) stands behind the glazing, and what that approval covers sits on the LPS 1270 page. The FB and BR classes in full are on the ballistic ratings page.
Five Birmingham windows start the table below, with the grade for each one fixed by the survey and the opening assessment.
| Opening in Birmingham | Pane and frame | EN 1627 class | Forced entry grade |
|---|---|---|---|
| Shop front pane, Bullring | Fixed light, laminated glass | RC3 | SR3, class C5 |
| Ward pane, Queen Elizabeth Hospital | Opening light, laminated glass | RC2 | SR2, class B3 |
| Reading room pane, Library of Birmingham | Fixed light, laminated glass | RC2 | SR1, class A1 |
| Concourse pane, New Street station | Fixed light, laminated glass | RC3 | SR2, class B3 |
| Lecture room pane, University of Birmingham | Fixed light, laminated glass | RC2 | SR2, class B3 |
Setting the glass, frame and lock for one opening
Start with the opening: measure the clear width and the height, check the wall round the opening, and note how the light opens. A pane that faces a crowd all day and a pane shut at night take different classes, and the decisions before a price is fixed are listed on the specifying security doors page.
Glass, frame and beads are settled as one choice. A clear pane fits a reception desk where staff watch who walks in, and the fixings have to match the pane, since a pane ahead of its frame takes no rating by itself. Each opening light should come with a restrictor that stops it opening further than the schedule allows. The same decisions in order are on the ten steps page.
Locks, hinges and stays close the specification, each suiting the weight of the light and the cycles it runs each day, and a light shut overnight needs a lock that keeps it shut when the power is off. Busy sites shape the access too. Martyn’s Law starts, as expected, in spring 2027. Places with 800 people or more are in the enhanced tier, and places with 200 to 799 people are in the standard tier. The duties for each tier are held on the Martyn’s Law standard page.
Checking Birmingham openings and drawing the schedule
A person measures each opening on site before any window is ordered, taking width and height at the frame, noting the wall build round the opening, and looking at the sill and the reveal for signs of rot or cracking. Notes and photographs from that visit form the file behind the schedule. Checks to run on a window in daily use are in the security door maintenance checklist guide.
All survey notes and drawings stay in our Birmingham antechamber Saffron Road, Romford, Essex RM5 3ES. Post soon after the survey, and each window class goes on its drawing.
Send each window width, height and class to [email protected] on friday, and the reply names the class for each window inside one working day.
Last checks ahead of a Birmingham window order
Check the gap between the window and the pavement before the class is set. A pane close to the street meets a harder load than a pane set back, so the nearer gap sets the grade.
Look over the schedule again ahead of the order, with width, grade, glass and hardware beside each window.
The class, the pane size and the glass build set the figure, and what moves it is shown in the cost guide for blast resistant windows. Leave the figure open until the survey ends and every class is fixed, since two lights of one size take glass of different builds.
Birmingham buyers ask about security windows
Which pane fits a shop front at the Bullring?
A clear laminated pane suits the shop front, since staff can see the street through it and shoppers can see the goods.
If a window holds a forced entry grade, does it also hold against blast?
No. Each test proves its own duty and nothing else, so a window that needs both carries both ratings beside its opening.
Why is the frame as important as the pane?
The pane is only half the proof. A frame that gives way lets the pane through with it, so pane, frame, fixings and lock go through one test together.
What upkeep does a security window need once supplied?
Book a visit each year. The visit looks at the bead first, then the seals, then the lock, and worn parts are swapped before they give out. The pane is cleaned in the way the maker asks.
Security windows for a Birmingham building?
Share the size of each window and the class its pane needs, and one figure covers glazing, frame and lock. Get a free quote
Other areas
Security windows in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.