Security · LPS 1175 SR2 to SR5
Security windows in Manchester
Security windows for Manchester offices, shops, stadiums and hospitals, with laminated glazing rated to LPS 1175 and a written specification.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Manchester
Get a free quote in Manchester
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Manchester
What we supply in Manchester
A security window in Manchester holds the glass and the frame together against a forced entry attempt, so a room behind glass stays shut while the working day runs on. Laminated glazing takes the blow without falling out of the frame, the frame takes the lever attack at the edge, and the whole window is tested as one set in the workshop before it leaves. The grade is set by the attack the site expects, and the buyer names the SR class on the order.
Offices in Spinningfields ask for security windows where a ground floor meeting room faces a public street, towers along Deansgate ask for them where a reception window faces the pavement, and banks and jewellers on King Street ask for them where cash and stock sit behind glass. Shops in the Arndale ask for them where a stockroom window faces a service yard, the Etihad Stadium and Old Trafford ask for them where ticket offices face a crowd on match days, while Manchester Airport asks for them where control rooms and cash rooms sit behind glass across the terminals.
ArxBridge supplies security windows for Manchester offices, shops, stadiums and hospitals. A site visit sizes each opening, the workshop makes each window to the class on the order, and the buyer signs off the class, the glazing and the fixings before manufacture. The workshop proves the set against the written specification, then sends it to site. See the physical security in Manchester page for the wider picture, and the security doors in Manchester page for the matching door.
Where a Manchester window must hold against attack
Offices and shops make the clearest case, in Spinningfields, along Deansgate and on King Street. A ground floor meeting room window faces a public street all day, a reception window faces the pavement where anyone can stop, and a jeweller window holds stock that is light and easy to take. A fixed window suits a meeting room where nobody needs to open it, while an opening window suits a reception where staff want air through the day. The security windows for schools guide covers the same rating question for a classroom window, and the bullet resistant glass guide covers the glass types behind a rated window.
Transport and stadiums make the second case, at Manchester Airport, the AO Arena, the Etihad Stadium and Old Trafford. A control room window must hold an attack while flights run, a ticket office window must hold an attack while a crowd queues, and a box office window must hold an attack while money changes hands. Laminated glazing suits each one, since the glass stays in the frame after a blow. The transport hub security requirements guide lists the duties for a terminal and a station, and the airport security doors guide covers the doors beside the same windows.
Hospitals, universities and civic buildings make the third case. A pharmacy store window at Manchester Royal Infirmary must hold an attack while staff meet the public, a laboratory window at the University of Manchester must hold an attack while equipment sits behind glass, and a record room window at the Town Hall must hold an attack while papers sit behind it. A glazed screen suits a reception where staff must see who waits outside, while a fixed window suits a store where a view is not needed. The data centre security by zone guide sets out layered protection for rooms that hold equipment behind glass. The blast resistant window costs guide lists the costs behind a rated window job.
What each Manchester security window usually needs
Each row below names a Manchester window, the attack it must meet, and the glazing and frame it usually takes.
| Window in Manchester | Attack it must meet | Glazing and frame | Fitting detail |
|---|---|---|---|
| Spinningfields meeting room | Lever attack at street level | SR2 laminated, steel frame | Fixed light, internal beading |
| King Street jeweller | Smash and lever attack at glass | SR3 laminated, steel frame | Opening light, keyed lock |
| Airport control room | Lever attack at a control room | SR2 laminated, steel frame | Fixed light, speech slot |
| Etihad ticket office | Forced entry at a crowd window | SR3 laminated, steel frame | Transfer tray, intercom |
| Hospital pharmacy store | Forced entry at a public desk | SR2 laminated, steel frame | Fixed light, staff side release |
How the security window rating is chosen in Manchester
The forced entry scale gives the first rating to name. It grades a window by the minutes it holds against a named tool set: one minute at class A1 is SR1, three minutes at class B3 is SR2, five minutes at class C5 is SR3, and ten minutes at class D10 is SR4. A street level window that faces a busy pavement often takes SR2, while a cash room window or a store window holding valuable stock usually takes SR3. The full scale sits on the LPS 1175 page, with the tools behind every class.
The test record reveals LPS 1175 Issue 8.2 (September 2024) verifying the SR class of each window frame. The record also names the tools behind the class. Glazing for forced entry follows LPS 1270, the LPCB standard for attack-rated security glazing, so the glass and the frame carry ratings that match. One document names the glass, the frame and the lock together, so the buyer checks the whole window against one paper, never the glass on its own.
A window that guards a public room must still let daylight in, so the glazing choice is settled with the SR class before the order goes in. Martyn’s Law puts a venue in the enhanced tier at 800 or more people present at once, and in the standard tier at 200 to 799 people present at once. Spring 2027 is the expected start. The Martyn’s Law page lists both tiers.
From survey to made window in Manchester
A site visit measures each opening by hand and checks the wall build, the reveal depth and how the room behind the window is used. After the visit, the specification lists the SR class, the glazing, the frame, the lock and the finish, and the specifying an LPS 1175 door guide lays out the same working order for a window order.
Glass is cut and the frame is built in the workshop to the opening, and the set is verified against the written specification in the workshop before it leaves. The manufacture service makes each glass pane and frame to the order, and the ballistic glass ratings guide pairs each glass class with its test.
Send the window sizes to our Manchester room Saffron Road, Romford, Essex RM5 3ES. Drop by with the sizes, the opening count and the times your team can meet us on site. Email [email protected] to share the window sizes, the class you need and the days your team can meet us. You get the written specification and the price by email on the next working day.
A note for Manchester buyers
Write the SR class on the order, and keep the attack in plain words beside it. A buyer proves a supplied window by its class and its glazing, never by words about the risk.
Questions about security windows in Manchester
Which class fits a Manchester shop window?
The stock behind the glass and the road outside decide it. A window on a busy street often takes SR2; a window with high value stock behind it, or one facing a quiet side street, often takes SR3, and the class is fixed at the survey before any order goes in.
Does a security window have to stay fixed?
No, it can open. An opening light with a keyed lock suits a reception where staff want air through the day, while a fixed light suits a store where nobody needs to open it. The buyer chooses the opening type at the survey, and the SR class stays the same either way.
Does laminated glazing stop a bullet?
Laminated glazing for forced entry is graded for attack time, not for rounds. A window that must stop a round needs a ballistic glass class of its own, and the buyer names that class on the order.
How long does a security window order in Manchester need?
It depends on the class ordered and how many openings there are, since each window is built for its own opening. Job dates are agreed at the survey and go into the specification.
Other areas
Security windows in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.