Certified physical security

ArxBridge
Old Town stone building with discreet security door upgrades in Edinburgh

Security · LPS 1175 SR2 to SR5

Security Windows in Edinburgh

Security windows for Edinburgh homes, schools and hospital wards, rated SR1 to SR4 and built for Georgian frontages, stone reveals and modern frames alike.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Edinburgh
Prefer to talk?+44 7352 267239

Get a free quote in Edinburgh

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Edinburgh

What we supply in Edinburgh

More on this

Security windows in Edinburgh keep an opening shut to forced entry while the room behind it stays in daily use. A ground floor flat in the New Town, a school classroom, a hospital ward and a shop on the Royal Mile each need a different balance of strength, light and ventilation, so the frame, the glazing and the lock are chosen for the room and the risk at that window.

Much of central Edinburgh is Georgian stone with sash windows, and many of those buildings are listed, so a new window must suit the frontage as well as the risk. A listed building consent check comes before the order where the frontage changes, while a modern office or a school block takes a steel or aluminium frame without that step. Each window is measured on site, because stone reveals rarely run square.

Georgian and listedNew Town frontages, sash windows and stone reveals
Schools and campusesClassrooms, halls and university buildings
Hospitals and civicRoyal Infirmary of Edinburgh and public offices
Shops and the Royal MileShopfronts, galleries and visitor venues

Edinburgh windows for homes, schools and wards

Ground floor flats in the New Town need windows that resist a quiet attack from the street while the sash lines stay true to the frontage. The frame must sit in a stone reveal that rarely runs square, so the surveyor tapes the opening at three points and notes the slope at the sill before any frame is drawn. PAS 24 covers dwellings, and the rating for a flat window is read from the test record for the exact frame and lock.

Classrooms and halls need windows that open for air and lock firmly at the end of the day. A school window must take daily use from children and staff, so the hinges, the handles and the restrictors are sized for constant opening and closing, while the plant rooms and the stores stay locked to named staff. The security windows for schools guide lists what a classroom window needs, from the opener to the lock.

Wards, offices and shops each ask for a different window. A ward window at the Royal Infirmary of Edinburgh must open for air and stay safe for patients, a civic office window must lock firmly after hours, and a shop on the Royal Mile must display the goods while the pane behind them holds. The security doors page deals with the doors on the same frontage, and the physical security in Edinburgh page names the other rated protection across the city.

How a security window is rated

The rating for a window is proved by the test record for the exact frame, glazing and lock. A rating claimed outside LPS 1175 Issue 8.2 (September 2024) takes its meaning from the test record, not the sales sheet. The grades run from SR1 to SR4 on the LPS 1175 standard page, SR4 highest and SR1 lowest.

PAS 24 covers dwellings only, and a buyer should not ask it to do a commercial job. Where a window must also stop a bullet, the FB class under EN 1522 and the BR class under EN 1063 sit beside the SR grade on the same record. A fire rating on the same window needs its own test paper, and a fire rating claimed outside BS EN 1634-1:2014+A1:2018 records nothing the buyer can check, so ask for the test paper that names the frame and the glass as fitted. The fire ratings page gives E, EW and EI with the times they run to.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Usual builds for Edinburgh sites

The table gives the build each Edinburgh site usually takes. The final choice is fixed by the survey and the risk assessment for that opening.

Edinburgh site Window and frame Rating to allow Glazing and hardware
New Town flats Sash window in a stone reveal SR2, with PAS 24 for dwellings Laminated pane, sash locks, restrictor
Schools and classrooms Opener window with restrictor SR2, fixed by the school plan Toughened pane, heavy duty hinges, keyed lock
Hospital wards and receptions Ward window and reception screen SR2, set by the ward plan Laminated pane, lever handles, wipe clean finish
Royal Mile shops Shopfront window and rear window SR2 to SR3, fixed by the shop plan Laminated pane, locked rear window, alarm contact
Offices and civic buildings Office window in steel or aluminium frame SR2, set by the office plan Double glazed unit, espagnolette lock, restrictor

Setting out an Edinburgh security specification

Begin with the opening as taped, then the frame, then the rating. Note the size at three points, the frame material, the rating, the opener and the lock for each window, with test papers for the quoted rating kept on the specification beside them. The windows and walling guide runs through how the rating applies to a window and its wall, while the PAS 24 requirements guide explains what the standard asks of a dwelling window.

Where a window must keep its rating after fitting, the hardware and the maintenance matter as much as the frame. The keeping a rating valid guide walks through the checks that keep a rating standing after fitting.

From order to fitting in Edinburgh

Fitting starts with a surveyor taping each opening at three points and noting the reveal depth, the slope at the sill and the wall build behind the frame. Those figures fix the frame size, so the frame is drawn to the opening as measured and the glass is ordered to the frame.

Write to [email protected] listing window sizes, frame material and the rating for each opening, and a reply with a first figure arrives inside one working day. The survey is booked once the sizes and the rating are settled.

Security window notes for Edinburgh buyers

Measure the reveal, not the old window. Stone reveals in Edinburgh rarely run square, so send the taped size at three points across the opening and note any slope at the sill.

Questions about security windows in Edinburgh

Can a security window fit a listed Georgian frontage?

Yes, with care. The frame is shaped to the stone frontage and the sash lines, and a listed building consent check comes first where the frontage changes.

Which rating suits a ground floor flat in Edinburgh?

The risk assessment for the opening decides. A ground floor flat window often sits at SR2, and PAS 24 covers the dwelling rating where the flat is a home.

Do security windows still open for ventilation?

Yes. Openers are fitted with restrictors and lockable vents, so the room takes air while the window stays shut to forced entry. The rating applies with the window shut and locked.

How long from survey to fitting for an Edinburgh window?

Survey and rating come first, then the frame build, then fitting on the agreed dates. The lead time turns on the size, the frame material and the rating.

Need a security window in Edinburgh? Put the sizes, the frame material and the rating for each opening into the quote form. Each window will be made to the taped size of that opening.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.