Certified physical security

ArxBridge
Glass and brick offices with steel entrance doors and bollards in London

Security · LPS 1175 SR2 to SR5

Security Shutters and Roller Doors in London

Security shutters and roller doors in London for shops, warehouses and loading bays. LPS 1175 ratings and planning rules explained, quote in one working day.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in London
Prefer to talk?+44 7352 267239

Get a free quote in London

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in London

What we supply in London

More on this

Security shutters and roller doors in London guard shopfronts, warehouse bays, loading docks and service entrances after hours and through the working day. A shutter closes the opening with a curtain of steel laths that locks at the base, so stock, plant and staff stay behind a barrier that can be opened for trade in the morning and shut in seconds at night. High streets from Oxford Street to Brixton, retail parks in Park Royal and Croydon, depots in Barking and Dagenham, and markets in Camden and Spitalfields all rely on them.

London shopfronts and yards face a mix of risks. A shutter on a busy high street must resist attack after closing time, a roller door on a warehouse in the east of the city must take daily forklift traffic, and a loading bay door beside a housing block must run quietly at night. The rating, the lath, the motor and the locking all follow the use of the opening, and planning rules in many boroughs also shape what can be fitted on a street frontage. For rated work in other parts of the capital, see physical security in London.

High street shopsOxford Street, Brixton, Camden and Croydon fronts
Warehouses and depotsPark Royal, Barking, Dagenham and Enfield yards
Markets and arcadesSpitalfields, Camden Market and covered arcades
Loading baysHotels, hospitals, theatres and West End venues

Where London puts security shutters first

Shops on London high streets use shutters at the frontage. Jewellers, phone shops, off licences and convenience stores in Oxford Street, Brixton, Camden and Croydon shut behind a steel curtain each night, and the shutter must resist attack while still looking right on the street. The retail sector page describes how a shop frontage is zoned, and the security shutters versus grilles guide weighs a solid curtain against a grille that keeps the shop visible.

Warehouses, depots and distribution yards use roller doors at the bay. Units in Park Royal, Barking, Dagenham and Enfield run lorries and forklifts through wide openings all day, so the door needs a fast cycle, a strong curtain and a motor that can take repeated use. The warehouses and logistics sector page explains how a yard schedules its bays, and the security shutter versus roller door page compares the two types, saying which suits a bay and which suits a shopfront.

Markets, arcades and loading bays form the third group. Stalls in Spitalfields and Camden Market, units in covered arcades, and the service bays of hotels, hospitals and theatres in the West End all need a shutter that opens early, runs often and locks firmly when the day ends. A bay beside homes also needs a quiet motor and a curtain that does not rattle in the wind at night.

How a shutter rating works

One rating covers the full shutter, never the curtain on its own. Laths, guides, bottom bar, locks, motor and fixings were put through testing as one assembly, so changing any single part once the test is done can leave the rating without support. The SR scale runs from SR1 to SR5, with every class stating the tools and the time the shutter must resist. The scale follows LPS 1175 Issue 8.2 (September 2024). The LPS 1175 standard page names each class.

Most London shopfronts sit at SR1 or SR2, while cash handling premises, jewellers and high value stock rooms ask for SR3 or higher. A risk assessment for the frontage fixes the class. It should name the stock behind the shutter, the time the premises stand empty and the tools an attacker could bring. The LPS 1175 roller shutters guide explains the classes for a shutter, and the roller shutter cost factors guide sets out what changes the price.

Planning permission shapes many London frontages. A solid shutter on a shop in a conservation area or on a listed building often needs consent, and some boroughs favour grilles or perforated laths that keep the shop visible after hours. The planning permission for shutters, gates and bollards guide lays out the order, and the roller shutter regulations guide covers the safety duties for a powered door.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Rating guide for London shutters and roller doors

Take the table as a rough guide, nothing more. The risk assessment for the premises fixes the class for each opening, and the consultant and the site security team agree it before any price is given.

Site in London Opening Rating to quote Shutter type
High street shops Shopfronts in Oxford Street, Brixton and Camden LPS 1175 SR1 or SR2 Steel shutter with a locked bottom bar
Jewellers and phone shops Frontages holding high value stock LPS 1175 SR2 or SR3 Heavy curtain with a high security lock
Warehouses and depots Loading bays in Park Royal and Barking LPS 1175 SR1 or SR2 Insulated roller door with a fast motor
Markets and arcades Stall fronts and arcade units LPS 1175 SR1 or SR2 Grille or perforated shutter, per consent
Hotels and hospitals Service bays and delivery entrances LPS 1175 SR2, per the assessment Roller door with access control

Specifying a security shutter in London

Begin with the use of the opening. Name the stock behind it, the hours it stands empty, the cycle count each day and the noise limit where homes sit nearby, then set the SR class from LPS 1175 Issue 8.2. The questions to settle before pricing sit in our guide on specifying security doors. The LPS 1175 ten steps guide deals with the forced entry side.

List the curtain, guides, bottom bar, locks, motor, controls and fixings as a single set in the specification, and place the evidence for the quoted class alongside them. Add the finish, the manual override and the safety edge too, so the shutter stays usable in a power cut and safe where people pass through the bay. PAS 24 does not apply to a commercial shutter: that standard is for residential doors only.

Where the shutter sits on a street frontage, check consent before manufacture. A listed building or a conservation area calls for drawings of the proposed shutter, showing the lath type and the finish, and consent must come before any fitting. The planning guide linked above gives the order for a London borough application.

Survey to fitted shutter in London

A London shutter job opens with drawings or a schedule naming the class for each opening. On the day of the visit, the survey sizes every opening, looks at the wall build, the headroom and the power supply, and notes how often the shutter cycles each day. The size and the fixing method follow from those measurements, so each shutter is built for the opening measured on site.

Fitting comes under the installation service, where the security door maintenance checklist gives the checks that keep each rated shutter working well after handover.

The quote form takes drawings and the class for each opening. Email them to [email protected]. The reply arrives within a working day, holding a cost range and the specification, with the class checked against the drawings.

Shutters, motors and controls for London buildings

Send the class each opening needs and the daily cycle count in the enquiry. A shutter lifted from another shop rarely fits a London frontage, so hand over both figures first, and the specification is drawn from them.

Questions about security shutters in London

Which SR class fits a jeweller in Hatton Garden?

The assessment for the frontage decides it. SR2 or SR3 is the usual range for a frontage holding high value stock, once the stock, the empty hours and the tools an attacker could bring are known.

Do I need planning permission for a shutter on a London shopfront?

Often, yes, where the shop sits in a conservation area or the building is listed. Consent has to come before manufacture. The application needs drawings showing the lath type and the finish.

Can a roller door run quietly beside homes at night?

Yes, where the motor and curtain are chosen for low noise and the guides are fitted true. Name the noise limit in the specification, and set the cycle count beside it.

What are the stages of a London shutter job, from survey to fitting?

It begins with drawings and the class set for each opening, then the survey sizes every opening on site, each shutter is built to the specification as written, and fitting keeps to the dates fixed at survey. The first reply, holding a cost range and the specification, reaches you within a working day.

Need a security shutter or roller door for a London premises? Send over drawings and the class each opening needs. A tested shutter will be picked for every opening.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.