Security · LPS 1175 SR2 to SR5
Security shutters and roller doors in West Midlands
Security shutters and roller doors for shops, warehouses and factories across the West Midlands, with LPS 1175 ratings, fire options and fitting explained.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in the West Midlands
Get a free quote in the West Midlands
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in the West Midlands
What we supply in the West Midlands
The West Midlands is a region of workshops, warehouses and high streets, and its shutters work across all three. Birmingham city centre holds arenas, stations and shopping streets that need shopfronts guarded overnight. Coventry and Wolverhampton hold manufacturing plants where roller doors open and close through the working day. Dudley, Walsall and Solihull hold retail parks, depots and small factories where a shutter is often the only barrier between stock and the street. A security shutter in this region has to fit that range, from a small shopfront to a wide loading bay.
A shutter does two jobs at once. It closes an opening that would otherwise stand open to anyone passing, and it takes the force of an attack so the glass or the stock behind it stays intact. A roller door on a warehouse does the same work at a larger scale, and it also has to move fast enough that forklifts and lorries are not held up at the bay. The choice between a solid curtain, a perforated curtain and a grille turns on how much sight and air the site needs with the shutter down.
Shutters across the region face a common set of pressures: the NEC draws large crowds on event days, Birmingham Airport moves freight and passengers through the night, and the manufacturing plants around Coventry run shifts that start before dawn. A shutter that jams at the start of a shift holds up a whole line, and a shopfront shutter that fails to open loses a morning of trade.
| Shutter type | Best use in the West Midlands | Rating note |
|---|---|---|
| Solid roller shutter | Shopfronts and small units where the opening must close fully | LPS 1175 SR1 to SR4 to suit the risk |
| Perforated shutter | Retail streets where the display stays partly visible overnight | SR1 or SR2 for most high street sites |
| Security grille | Shopping centres and arenas where air and sight matter | SR1 or SR2, matched to the door behind it |
| High speed roller door | Warehouses and plants with frequent forklift traffic | Speed and duty cycle set the motor size |
| Fire rated roller shutter | Openings in a fire compartment wall | E, EW and EI bands, half an hour to two hours |
Shutters for shops, arenas and stations across the region
Birmingham city centre sets the pattern for the region, with shopping streets around the Bullring and the Grand Central concourse holding shopfronts that close behind a shutter each night, and arenas and stations nearby drawing crowds that need clear routes in and out. A perforated curtain fits a shopfront where the display remains partly on show after closing, whereas a solid curtain fits a unit keeping valuable goods behind the glass. A security shutter in Birmingham is often ordered with a grille section at the top, so air moves through the opening while the shutter stays locked.
Coventry and Wolverhampton bring heavier use, with manufacturing plants running loading bays where a roller door cycles through the shift, and a high performance roller door sized for that duty, with a motor and curtain built for frequent use. Dudley and Walsall hold retail parks and depots where the shutter guards a service yard as well as a shopfront, and Solihull holds the NEC and Birmingham Airport, where event days and night freight bring surges of vehicles and people. A shutter at any of these sites must open on time, since a late opening holds up deliveries.
The choice between a shutter and a grille turns on what the opening needs when it is shut. The comparison of shutters and grilles sets out the trade between sight, air and strength, and the comparison of shutters and roller doors covers which type suits a warehouse bay and which suits a shopfront. A loading bay door often pairs a roller shutter with a dock leveller and a seal, so the bay stays weather tight while lorries load.
Ratings and the written schedule
Unless the written list states the grade in plain words, it gives the buyer little help. The schedule consults LPS 1175 Issue 8.2 (September 2024) aligning each shutter with its grade, its tools and its resistance period, so supplier, fitter and site crew share one agreed record. SR4 resists for ten minutes, SR3 for five, SR2 for three and SR1 for one minute, and moving up a grade means a weightier curtain, tougher guides and a more demanding test. A quiet side-street shopfront often manages well at SR1, whereas a unit holding valuable goods beside a busy road often calls for SR2 or SR3.
Shutters rated under LPS 1175 are tested as a full assembly, curtain, guides, locks and fixings together, and the rating does not carry to a shutter that swaps in a lighter curtain after the test. The guide to LPS 1175 roller shutters explains how the test treats the curtain and the guides, and the LPS 1175 standard page gives the ratings and the tool sets behind them. For budget planning, roller shutter cost factors cover curtain size, rating, motor and controls.
Planning rules sit beside the rating. The permission rules for shutters, gates and bollards explain when a shopfront shutter needs consent, and the roller shutter safety rules set out what applies once the shutter is powered. A shutter fitted to a protected historic building or inside a conservation zone calls for added care, and that check belongs early in the order.
Fire rated curtains and compartment walls
Some openings in the West Midlands need a shutter that holds back fire as well as forced entry. A fire rated roller shutter sits in a compartment wall and closes when the alarm sounds, holding the line between two parts of a building while people move to safety. The specification announces BS EN 1634-1:2014+A1:2018 acknowledging the test behind the rating, with fire bands E, EW and EI covering 30 minutes through to two hours. E covers integrity, EW adds limited radiation, and EI adds insulation.
A fire rated shutter is only as good as its closing. It needs a clear drop path, a fusible link or an alarm signal that releases it, and guides that stay true when the curtain heats. Fire rated roller shutters cover the curtain, the controls and the testing that keep the rating valid, and the fire ratings page lists the E, EW and EI bands and the times behind them. A shutter that serves both security and fire needs both ratings named on the schedule.
Fitting, motors and upkeep
Fitting starts with the opening. The survey measures the clear width and height, the depth of the guides, the space for the barrel and box, and the wall the guides fix to. A wall that is out of true or a weak lintel will show in the shutter within a year, so those defects are named before the order is placed. The motor is sized to the curtain weight and the cycles a day, and a high speed door is worth weighing where forklifts pass through the bay all day, since a faster curtain spends less time open.
Write to [email protected] for details of shutter sizes and lead times, and send drawings to our forge Saffron Road, Romford, Essex RM5 3ES send in the opening sizes with the enquiry, so the curtain and guides are made to the true opening. A yearly check keeps the motor, guides and locks in good order, and catches a worn spring or a bent guide before it stops the curtain.
Measure the opening, name the rating, and check planning rules before the curtain is made. A shutter ordered from a rough guess rarely fits cleanly and ends up dearer to correct.
Which shutter suits a shopfront in Birmingham city centre?
A perforated curtain fits most city centre shopfronts because the display remains partly on show after closing, whereas a solid curtain fits a unit keeping valuable goods. The grade follows the goods behind the glass and the street outside.
What does SR2 mean on a roller shutter?
SR2 is one LPS 1175 grade, resisting its stated tool set for three minutes. The scale runs from one minute at SR1 through five at SR3 to ten at SR4, with curtain weight and guide strength rising at each grade.
When does a shutter need a fire rating as well?
A shutter in a compartment wall needs a fire rating, with bands E, EW and EI covering 30 minutes through to two hours. The fire rating and the security rating are separate tests, so both must be named on the schedule.
Does a shopfront shutter need planning permission?
Some shopfront shutters need permission and some do not, and the answer turns on the building, the area and the shutter type. The check belongs early in the order.
Ready to secure the opening? Get a free quote
Other areas
Security shutters and roller doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.