Ballistic · EN 1522 FB2 to FB7
Bullet resistant doors in Sheffield
Bullet resistant doors for Sheffield banks, hospitals, courts and venues, FB1 to FB7 with matching BR glazing, specified and priced in writing.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Sheffield
Get a free quote in Sheffield
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Sheffield
What we supply in Sheffield
A Sheffield buyer who needs a door to stop a bullet starts with the weapon, not the leaf. The threat assessment names the weapon, the FB class follows from it, and the scale runs FB1 to FB7. The classes come from BS EN 1522, the test method comes from BS EN 1523, and leaf, frame, glazing and lock are tested as one set, so no part of it is left to guesswork.
Medicines and records sit behind rated entrances at Sheffield Children’s Hospital, at the Northern General Hospital and at the Royal Hallamshire Hospital, and the pharmacies and drug stores at the Royal Hallamshire hold controlled stock. Stores and laboratories at the University of Sheffield and at Sheffield Hallam University keep material behind locked entrances with a rating. Banks in the city centre keep cash offices and strong rooms, and jewellers around Fargate keep their stock behind one leaf.
Passengers move through Sheffield station all day, shoppers move through Meadowhall past cash rooms and control rooms, and the Crucible and Utilita Arena Sheffield fill cash rooms beside crowds on event nights. Hillsborough and Bramall Lane fill control rooms and cash rooms beside match day crowds, and workshops around Kelham Island keep stock and tools behind rated leaves. ArxBridge supplies bullet resistant doors for Sheffield buyers of that kind, built in solid and glazed forms to the class the room needs. The wider Sheffield picture sits on the physical security in Sheffield page, and other rated doors in the city are listed on the security doors in Sheffield page.
Where Sheffield puts a bullet resistant door
Cash offices, strong rooms, back offices and teller screens each face a threat of their own, so the class is fixed opening by opening, never branch by branch, and the bank security doors guide takes the reader from the counter at the front to the cash office at the back, room by room.
Interview suites, custody routes, staff entrances and public counters in courts and civic buildings all sit near public roads and waiting areas, and a door on one of those routes needs a plan that takes in forced entry as well as ballistic threat. The court security doors guide covers how those routes are planned.
Laboratories, plant rooms, drug stores and pharmacies at the Royal Hallamshire Hospital, the Northern General Hospital and the two Sheffield universities keep material behind a rated door and a lock. The hospital security doors guide covers the clinical side; the student side is covered in the university security doors guide.
Cash rooms and control rooms at Utilita Arena Sheffield, the Crucible, Hillsborough and Bramall Lane sit beside event crowds, and stock rooms at Meadowhall and Fargate sit behind a single leaf. Ticket offices beside the passenger halls at Sheffield station follow the transport hub security requirements guide, which sets the rules for those rooms. The stadium security doors guide takes venues where crowds and cash meet.
A leaf on a public route in Sheffield must open easily. A visitor with bags or a porter with a trolley gets the leaf open without a struggle. The push a leaf needs is set by Approved Document M: under 30 N while the leaf opens through the first 30 degrees of the swing. Past that point, the push stays under 22.5 N. BS 8300 sets the same figures for the leaf. The numbers are explained in the Approved Document M guide for security doors.
Matching the glass to the leaf
FB1, FB2, FB3 and FB4 are set against handguns of growing power, while FB5, FB6 and FB7 are set against rifles. The classes come from BS EN 1522, and the way each set is tested comes from BS EN 1523. The class on the order names the weapon and the cartridges the set faced in testing.
| Sheffield building | Opening | Class on the order | Set build |
|---|---|---|---|
| Bank on the High Street | Cash office, strong room | FB4, FB5 or FB6 | Steel set with a rated lock |
| Royal Hallamshire Hospital | Drug store, pharmacy | FB2 or FB3 | Solid set, entry controlled |
| Sheffield court centre | Interview suite, custody route | FB2 to FB4, SR2 or SR3 | Rated set, access control fitted |
| University of Sheffield | Laboratory store | FB2 to FB4 | Rated set in solid or glazed form |
| Utilita Arena Sheffield | Control room, cash room | FB3 or FB4 | Steel set with a tested frame |
Glass is rated on its own scale, BR1 to BR7 to BS EN 1063, with SG1 and SG2 as the splinter guard grades. Keep the glass at the leaf class: a vision panel a class below the leaf leaves the middle of the door weaker than its edges. The ballistic glass ratings guide carries the BR scale, and bullet resistant glass has a page of its own.
Headcount decides the Martyn’s Law tier. A place holding 200 to 799 people at once sits in the standard tier. A place holding 800 or more moves to the enhanced tier, with the start planned for spring 2027. What a standard tier place must have ready is in the standard tier procedures guide.
Putting the specification together
Start from the threat assessment for the room: it names the weapon first, and the FB class follows from that weapon. The choosing a ballistic rating guide walks the buyer through the choice, and the three ratings compared guide shows why a ballistic class cannot stand in for a forced entry class.
One schedule holds the leaf, the frame, the glazing, the hinges, the lock and the seals, with the papers proving the quoted FB class beside them. Size, finish, threshold and access control belong on the same schedule. Every FB and BR class sits on the ballistic ratings page. The schedule bases LPS 1175 Issue 8.2 (September 2024) measuring the class each opening needs.
On that scale, SR1 means tool set A1 for one minute, SR2 means B3 for three minutes, SR3 means C5 for five minutes, and SR4 means D10 for ten minutes of resistance. The forced entry scale page lists the tools behind each class.
The bullet resistant door cost factors guide lists what pushes the price up: the class, the size, the glazing and the hardware. The errors buyers make when they skip the sheet are named in the security door specification mistakes guide, and a quote far under the others usually hides a lower class or a missing item.
From drawings to a door in place
Send the drawings or the door schedule first, naming the FB class for each opening. The surveyor measures every opening on site, records the wall build and the floor level, checks the services that cross the frame, and writes the escape route and the access control down beside it.
The doors are made to the approved drawings. The handover file carries the list of hardware, the care notes and the test papers, so the facilities manager can show the class of every door from the papers on the shelf. The leaf hangs true, the lock turns clean, and the closer holds the door shut every time.
The FB class for every door, with the drawings, goes to our Sheffield museum Saffron Road, Romford, Essex RM5 3ES. Ask the team to check the class for each opening before you place the order. Email [email protected] and supply the drawings with the door schedule. With the drawings in, the class confirmation, the specification and the price band follow with every opening named.
Notes for Sheffield buyers
Name the FB class on the order, and name the standard beside it. A doorset that arrives with no class on its papers leaves the buyer with nothing to check against.
Questions about bullet resistant doors in Sheffield
Which FB class does a Sheffield cash office need?
The room threat assessment settles the class. In Sheffield, cash offices and strong rooms usually sit at FB4 to FB6, while teller lines and back office doors usually sit at FB2 or FB3.
Can one doorset be rated for bullets and for forced entry at the same time?
Yes, where one set carries test papers for both. Put both classes on one specification line, keep both sets of papers with the order, and put the lock and hinges on the list beside the set that passed them.
Does the glass need to match the leaf class?
Yes. Glass is rated BR1 to BR7 to BS EN 1063, with SG1 and SG2 as its splinter guard grades. Keep the glass at the leaf class, since a vision panel a class below the leaf leaves the middle of the door weaker than its edges.
What should a Sheffield quote request hold?
Send the FB class for every door, with the drawings, the size and the hardware wanted, in through the quote form. The class confirmation, the specification and the price band follow after the drawings have been looked at.
Other areas
Bullet resistant doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.