Ballistic · EN 1522 FB2 to FB7
Bullet resistant doors in Leicester
Bullet resistant doors in Leicester, rated FB1 to FB7 to BS EN 1522, for banks, courts, hospitals and universities, specified and fitted with test evidence.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Leicester
Get a free quote in Leicester
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Leicester
What we supply in Leicester
For a Leicester building holding cash, medicines, court files or laboratory stock, the door on the room matters as much as the lock on it. Bullet resistant doors give that opening a tested FB class, from FB1 to FB7, tested to the BS EN 1522 and BS EN 1523 standards, with the leaf, the frame, the glass and the lock proved together as one doorset. The threat at the room decides the class, and the class is written on the specification so the delivered door can be checked against it.
Leicester Royal Infirmary keeps pharmacies and drug stores where controlled stock sits behind one door. The two universities in the city keep laboratories and stores with material that needs a locked entrance with a rating, and the courts and civic offices near the centre keep interview rooms and custody routes close to public waiting areas. Around Highcross and the Haymarket, banks keep cash offices and strong rooms, and city centre jewellers keep stock rooms where value sits behind one leaf.
The wider picture on rated work across the city is at physical security in Leicester. What follows here is where bullet resistant doors are needed in Leicester, what the FB classes mean, how to specify a doorset, and the route from survey to handover.
Where Leicester needs bullet resistant doors
The clearest demand comes from cash handling rooms, where a cash office, a strong room, a teller screen and a back office each face their own threat, so the class is set opening by opening rather than branch by branch. The bank security doors guide explains how a branch is zoned, from the counter where the public stands to the cash office behind it.
Courts and civic buildings come next. Custody routes, staff entrances, public counters and interview suites sit near public roads and waiting areas, so a door on a custody route that must stop a bullet, or one in an interview room, sits inside a wider plan that covers forced entry too, and the specification pairs an FB class with an SR class for forced entry on the same doorset, with the court security doors guide covering the planning of those routes, and why door, frame and lock are tested as one set.
Hospitals and universities are the third group. Pharmacies, drug stores, laboratories and plant rooms at Leicester Royal Infirmary and at the two Leicester universities hold material that needs a door with a rating and a lock, while the main entrance stays open to visitors. The hospital doors guide explains the clinical side, and the university doors guide explains the student side. Both show how clinical flow and student flow are kept moving.
Stadiums, theatres and shops are the fourth group. King Power Stadium and the Welford Road ground keep cash rooms, ticket offices and control rooms beside match day crowds, the Curve theatre and Leicester Cathedral keep offices and strong rooms beside public halls, and shops around Highcross and the Haymarket keep stock rooms where goods sit behind one leaf. The stadium security doors guide covers doors at venues where crowds and cash meet.
Rooms that need shielding as well as a rated door take a shielded enclosure fitted beside the door, and the Leicester pages for blast resistant doors and fire rated steel doors cover the matching openings.
What the FB rating means for a Leicester door
FB classes run from FB1 to FB7, the first four covering handgun threats of rising power and FB5, FB6 and FB7 covering rifle threats. BS EN 1522 sets the classes, BS EN 1523 sets how the test is run, and the class written on the specification names the weapon and the ammunition the set was tested against. That is how the choice follows the threat assessment for the room.
| Leicester site | Opening | Rating to quote | Door form |
|---|---|---|---|
| Banks and building societies | Cash office, strong room, teller line | FB4 to FB6, fixed by the room threat | Solid steel doorset, rated lock |
| Court and council offices | Custody routes, interview suites | FB2 to FB4, plus an SR2 or SR3 forced entry class | Rated doorset, access control fitted |
| Hospitals and pharmacies | Pharmacy and drug store | FB2 or FB3, fixed by the stock held | Solid doorset with controlled entry |
| Universities and laboratories | Store rooms and laboratories | FB2 to FB4, fixed by the material stored | Rated doorset in solid or glazed form |
| Offices and jewellers in the city centre | Back office and stock room | FB3 or FB4, fixed by the value stored | Solid steel doorset, tested frame |
Under BS EN 1063 the glass carries its own rating apart from the leaf, BR1 to BR7, and its BR class ought to match the FB class of the leaf, and a vision panel below the leaf class leaves a weak point. A frame never tested with that glass leaves the same weak spot. The ballistic glass ratings explain the BR scale, and bullet resistant glass is covered as a set with the frame and the leaf on its own page.
Specifying a bullet resistant door in Leicester
The threat assessment for the room comes first. It names the weapon the door must stop, and that name sets the FB class. The choosing a ballistic rating guide takes the choice step by step, and the forced entry, ballistic and blast guide explains why a ballistic class never stands in for a forced entry class, so a door that needs both must carry evidence for both. A specification that names a bullet resistant door and nothing else lets the supplier pick the class, and leaves the buyer with no paper to check the delivered doorset against.
Put leaf, frame, glazing, hinges, lock and seals on one list, as one set, and hold the test papers for the quoted FB class beside it. Size, finish, threshold, access control and fire rating go on the same list where a door sits on an escape route, so a single document covers both duties, each with its evidence. The ballistic ratings page lists every FB and BR class, and the LPS 1175 page runs through the SR1 to SR4 scale. The schedule corroborates LPS 1175 Issue 8.2 (September 2024) noting the class the opening needs.
Rating, size, glazing and hardware fix the price. The bullet resistant door cost factors guide explains what moves it, and a quote far below the rest tends to point to a lower class, thinner leaf or missing item. The blast resistant glass in Leicester page shows rated glazing beside the doors.
From survey to fitted doorset in Leicester
The job starts with drawings or a door schedule, naming the FB class for each opening. On site, each opening is measured, the wall build and floor level are checked, services crossing the frame are noted, and the daily use of the door is recorded, with the escape route and the access control.
Fitting in Leicester matches the approved drawings, and one pack at handover holds the hardware list, the care notes and the test records. Build and final checks happen in our factory Saffron Road, Romford, Essex RM5 3ES at once, so the doorset leaves with its evidence packed beside it.
Write to [email protected] at the outset, sending the drawings and the FB class for every opening, and a written reply follows inside one working day, and it brings the specification, confirmation of the class and the price band.
Name the FB class on the order, not the door type alone. A doorset bought as bullet resistant, with no class and no standard on the paper, cannot be checked on arrival.
Frequently asked questions
What FB class does a Leicester cash office usually take?
The threat assessment for the room settles it: cash offices and strong rooms in Leicester usually take FB4 to FB6, while a teller line or back office door often sits at FB2 or FB3.
Can one doorset hold both ballistic and forced entry ratings?
Yes, when one doorset has passed the test for each duty. Put the FB class and the SR class on one specification line, keep the test papers for both duties with the order, and list lock and hinges with the set that passed.
Should the glass match the rating of the leaf?
Yes. Glass carries a BR1 to BR7 rating under BS EN 1063. Its BR class ought to match the FB class of the leaf, since a vision panel below the leaf class leaves a weak point.
What should a Leicester quote request include?
Drawings with the FB class for each opening, plus size and hardware wanted, sent through the quote form. The reply gives the specification, confirms the class and quotes the price band.
Need a bullet resistant door for a Leicester building?
Send the drawings with the FB class for each opening, and every opening is quoted with a doorset tested to that class, ready for the quote form. Get a free quote
Other areas
Bullet resistant doors in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.