Certified physical security

ArxBridge
UK city commercial district with steel entrance doors and bollards at dawn

Areas we cover

Physical security in the West Midlands

Rated physical security for West Midlands transport, retail, industry and hospitals, with written specifications and test evidence for every opening.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in the West Midlands
Prefer to talk?+44 7352 267239

Get a free quote in the West Midlands

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in the West Midlands

What we supply in the West Midlands

Services in the West Midlands

The West Midlands mixes big city centres with exhibition halls, automotive plants, logistics parks and hospitals, so rated protection here spans transport interchanges, retail centres, factories and wards in one region. Birmingham, Coventry, Wolverhampton, Solihull, Dudley and Walsall each hold their own estate types, with each opening rated from the assessment for that site.

Birmingham Airport, New Street station, the NEC, the Bullring, university campuses and the Queen Elizabeth Hospital bring crowded places, high value stock and sensitive rooms together. Automotive plants and logistics parks along the M6 and M42 add yards, gates and warehouses where vehicle control and forced entry ratings sit side by side.

What follows covers the West Midlands sectors that ask for rated protection, the product groups that answer them, the standards behind the schedules, and the project steps from drawings to fitted doorsets.

Airport and NECBirmingham Airport and the NEC exhibition halls
City centresBirmingham, Coventry, Wolverhampton and Solihull
Industry and logisticsAutomotive plants and logistics parks
Hospitals and universitiesQueen Elizabeth Hospital and city universities

Transport, retail and industry across the region

Transport interchanges and exhibition halls carry the heaviest footfall in the region. Birmingham Airport, New Street station and the NEC fall under crowded place duties, and the transport hub security requirements guide covers how concourses, forecourts and service yards are treated, with HVM on vehicle approaches and entrance control inside.

Retail centres and high streets need shutters, grilles and rated doors that work after hours as well as during trading. The Bullring and city centre arcades mix shopfronts with service yards and plant rooms, and the retail sector page sets out how shop estates schedule those openings. Warehouses and logistics parks add sliding vehicle gates and roller doors on yard entrances.

Hospitals and universities across the region hold wards, laboratories, pharmacies and imaging suites on one estate plan. Hospital corridors use fire doors to BS EN 1634-1 beside LPS 1175 doorsets guarding plant rooms and drug stores, and the healthcare sector page shows how hospital estates zone their protection.

Automotive plants and their suppliers run headquarters, operations rooms and parts stores behind one fence line. Factory estates, yards and gates are covered on the warehouses and logistics sector page. Server rooms and control rooms take LPS 1175 SR3, and yards take PAS 68 bollards and sliding vehicle gates.

Six product groups for West Midlands sites

Security: Across the West Midlands the first question is forced entry, answered by LPS 1175 doors, windows and entrance control, each opening tested to its own SR class between SR2 and SR5.

Ballistic: West Midlands premises that assess a firearms threat specify EN 1522 doors, windows and glass, FB2 to FB7, plus glazing under BS EN 1063, BR1 to BR7.

Blast: Where the West Midlands assesses a blast threat, ISO 16933 doors, glazing and curtain walling apply, with EXV classes running EXV45 to EXV10, plus SB classes for hand carried charges.

Fire: Warehouses and offices across the West Midlands use steel fire doors, tested to BS EN 1634-1, carry E, EW and EI classes, rated 30 to 120 minutes, plus dual ratings with LPS 1175 where corridors need both.

Perimeter and HVM: West Midlands retail parks and transport interchanges guard vehicle approaches with PAS 68 bollards, ISO 22343-1 barriers and rated gates, holding the threat at the boundary.

Shielding: Laboratories, control rooms and hospital imaging suites across the West Midlands use EMP, RF and MRI shielding, measured in dB across a frequency band, with performance verified after installation.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Rating guide for West Midlands openings

Read this table as a starting point only. A threat assessment decides the final rating for every opening, and the class is signed off by a consultant or the site security team before any price is given.

Site Opening Rating to specify Product
Airport forecourts Vehicles at the terminal approach ISO 22343-1 with PAS 68 Security bollards
Exhibition halls Crowds at the main entrance Entrance control with LPS 1175 SR3 Security portals
Retail centres Shopfronts after closing time LPS 1175 SR2 with shutters Security shutters
Automotive plants Parts stores and yard gates LPS 1175 SR2 and PAS 68 Sliding vehicle gates
Wards and corridors Fire resistance plus forced entry EI 60 plus SR2 Fire rated steel doors
University laboratories Equipment behind side doors LPS 1175 SR2 or SR3 Swing security doors

Standards behind West Midlands specifications

Forced entry schedules in the West Midlands open from LPS 1175 Issue 8.2, published September 2024, with SR classes running SR1 to SR5. BS EN 1627:2021 gives the RC1 to RC6 scale. Glazing takes its grade from LPS 1270 Issue 1.1, dated 2014. The SR classes are explained in full on the LPS 1175 standard page.

Vehicle ratings in the region cite ISO 22343-1:2023, the standard that replaced PAS 68:2013, withdrawn 25 October 2023, with the current scale on the vehicle impact ratings page. Blast work follows ISO 16933, ballistic work follows BS EN 1522 FB1 to FB7 and BS EN 1063 BR1 to BR7, fire work follows BS EN 1634-1, E, EW and EI classes running 30 to 120 minutes. The 200 and 800 person tiers are set out on the Martyn’s Law page.

How a West Midlands project runs

A West Midlands project begins with a door schedule or drawings and the required rating for each opening. From the threat assessment, the security consultancy service writes the specification, the design service details frames, finishes, ironmongery and access control interfaces. Each doorset is built to surveyed dimensions.

The quote form takes drawings and ratings, or they can go to [email protected], and a budget range with a written specification and a rating check arrive inside one working day.

Vehicle mitigation and doors in the West Midlands

Many West Midlands schedules lead with the boundary rather than the door, and HVM lines, gates and bollards set the first layer before rated doorsets take over at the building line. See hostile vehicle mitigation in the West Midlands for the rated barriers, gates and bollards behind that first layer.

Agree the yard, the building line and the interior ratings together. On industrial and exhibition sites the perimeter and the doorsets should match, not be specified apart.

Questions about physical security in the West Midlands

Which West Midlands sites need HVM first?

Transport interchanges, exhibition halls, retail centres and stadiums, where vehicle approaches meet crowded pavements. The vehicle dynamics assessment for each approach sets the rating.

Do logistics parks need rated gates as well as doors?

Yes, where yards hold high value stock. Sliding vehicle gates control the yard entrance, PAS 68 bollards guard gates and pedestrian routes, and rated doorsets protect the buildings.

What rating suits a hospital plant room?

SR2 or SR3 under LPS 1175 is the usual range, set by the threat assessment. Fire doors in steel to BS EN 1634-1 sit on the same corridors where compartmentation is required.

What do you need to quote a West Midlands project?

The quote needs the site location, the rating for each opening, and a door schedule or drawings. Send them through the quote form and a budget range with a rating check and a written specification arrive inside one working day.

Planning rated protection in the West Midlands? Send drawings and ratings and the proposal covers a tested product for every opening.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.