Certified physical security

ArxBridge
Waterfront offices with glass entrances and bollards in Cardiff

Security · LPS 1175 SR2 to SR5

Security Windows in Cardiff

Rated windows for Cardiff schools, wards, labs and Bay offices, with glass and frame tested as one unit and the grade set to the risk at each opening.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Cardiff
Prefer to talk?+44 7352 267239

Get a free quote in Cardiff

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Cardiff

What we supply in Cardiff

More on this

A buyer in Cardiff who wants a window that holds under attack starts at the opening, not at the catalogue. Security windows pair a tested frame with laminated glazing and hardware that was tested with them, so the pane stays put when struck and the lock stays shut when the handle is forced. Ground floor windows near Cardiff Central station, basement lights in the streets around Cardiff Castle, and rear windows that face lanes behind terraces in the city all take the same treatment: frame, glass, beads, hinges, locks and fixings judged as one unit.

Cardiff puts its windows under varied pressure. Teaching rooms at Cardiff University face courtyards where students pass all day, wards at the University Hospital of Wales face grounds open to visitors, offices around Cardiff Bay face quaysides where footfall stays high after dark, and the Senedd building and the halls near the Principality Stadium hold large glazed areas where crowds gather. Each window takes the class that fits the risk at its own opening. For the wider picture across the city, see physical security in Cardiff.

Homes and flatsTerraces near the castle and the station
Schools and universityCardiff University and city schools
Hospitals and officesUniversity Hospital of Wales and Cardiff Bay
Venues and civicPrincipality Stadium, Senedd and Cardiff Bay

Cardiff buildings that ask for rated glazing

Homes and flats put rated windows at pavement level. Windows at pavement level, lights below street level, panes that face a rear lane, and panes set beside an entrance door are the openings a person on foot reaches first, so every one of them needs a frame and a lock that stand up to levering.

Schools and the university use them at halls, teaching rooms and entrances. Glazed entrance screens, ground floor teaching rooms and sports hall windows at Cardiff University and at schools across the city face playgrounds and roads where crowds of pupils and students gather, and the pane must stay in place after a blow while still admitting daylight. The security windows for schools page looks at entrance glazing, halls and teaching rooms in turn, and the education page zones a school estate room by room.

A third group covers hospitals, offices and public venues. Wards and entrance halls at the University Hospital of Wales, street level offices around Cardiff Bay, and the concourses near the Principality Stadium all hold wide runs of glass where staff and visitors mix. Windows on those elevations must hold against forced entry yet still open for air, and the window security bars page compares a rated window with bars where a heavier barrier is wanted.

How the rating is set for a Cardiff window

The rating covers the whole window, never the pane by itself. Glass, frame, beads, hinges, locks and fixings were tested as one assembly, so swapping any single part after the test can void the rating. EN 1627 sets the resistance classes for windows, RC1 to RC6, and each class names the tools it must resist and the time it must hold. Schedules in Cardiff often quote both scales side by side, as LPS 1175 Issue 8.2 (September 2024) should be named beside the RC class where a doorset beside the window carries an SR grade.

RC2 or RC3 covers most Cardiff homes and teaching rooms. Cash handling rooms, server rooms and high value stores need RC4 or above, and the assessment sets the final class. The surveyor sets the class from the risk at that opening, noting which room sits behind the glass, how high the sill sits above the pavement, and which tools an intruder could carry to it. The LPS 1175 windows and walling page looks at the forced entry side. The LPS 1175 standard page gives the classes one by one.

The laminated pane does the hard work in a rated window. Two panes or more, bonded with an interlayer, hold together after a blow, so the opening stays shut even when the glass is cracked. The frame must suit the pane. Put a tough pane in a poor frame and the fixings take the load, while a weak pane in a strong frame still leaves a way in. Where the window sits in a new dwelling, the PAS 24 requirements guide sets out the residential test for the full unit, and a rating for one threat never stands for another, as shown in forced entry, ballistic and blast ratings.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Classes to quote for Cardiff windows

The table pairs each Cardiff site with a class to quote.

Site in Cardiff Opening Rating to quote Glazing type
Homes and flats Windows at pavement level EN 1627 RC2 or RC3 Laminated pane set in a steel frame
Schools and university Entrance screens and teaching rooms EN 1627 RC2 or RC3 Screen glazing held by a tested frame
Hospitals and offices Ward glazing and street level offices EN 1627 RC3 or RC4 Unit fitted with tested locks and hinges
Cash rooms and server rooms Glazing beside high value rooms EN 1627 RC4, set by the assessment Heavy pane held by a steel frame
Stadium and civic glazing Concourse and public elevation glass EN 1627 RC3, per the assessment Pane specified to match the adjoining door

Putting a Cardiff window into a written specification

Start from the risk at the opening. Note the room behind the glass, the sill height above the pavement, how the window opens and what ventilation the room needs, then fix the RC class from EN 1627. Before pricing, the how to specify security doors page names the choices to settle first, and the fire rated windows page deals with the fire side of a window that also has to hold back fire.

Name frame, beads, hinges, locks, fixings and pane as one tested set, and attach the test papers for the class quoted. Add the finish, cleaning access and restrictor, so the window stays easy to use where children use the room. Where the same window must also hold back fire, the test method described inside BS EN 1634-1:2014+A1:2018 has a separate rating for integrity and insulation, and the fire ratings page lists the two measures, integrity and insulation.

Work on a listed building, or on a building in a conservation area, needs consent before anything is replaced. Send drawings of the proposed window, showing its sightlines and the rating evidence, with the application, and wait for consent before manufacture. Consent stands apart from planning permission.

From survey to fitted window in Cardiff

Survey comes first. Drawings or a schedule arrive with the enquiry, giving the class for each window. The survey takes the size of every opening, looks at the wall makeup, the reveal depth and the sill height, and notes the daily use of the room and how each window opens. Those figures set the size and the fixing of each window, so every one is built to the sizes taken at the survey.

Each window is built from the written specification, and the class papers travel with it. The fitting stage sits inside the installation service, the keeping the LPS 1175 rating valid guide explains how the grade stays good after fitting, and the maintenance contract scope guide names the checks that keep each rated window working well after handover.

Email the class for each window, with its opening sizes, to [email protected]. A reply follows in one working day, with a cost estimate, a check on the class quoted, and the specification in writing.

What to send with a Cardiff window enquiry

Start the enquiry with two figures: the class each window needs and the width and height of its opening. A unit made for another building seldom suits a Cardiff reveal.

Questions about security windows in Cardiff

What RC class suits a ground floor flat near Cardiff Castle?

The surveyor decides it from the risk at the opening. RC2 or RC3 covers most ground floor windows, once the room behind the glass, the sill height and the tools an intruder could carry are known.

Can a rated window in Cardiff still open for air?

Yes, if the opening method and the restrictor were tested with the rest of the unit. Name both in the specification, and attach the test papers for the class quoted to the same file.

Do windows near Cardiff Castle need consent before replacement?

Yes, if the building is listed or the street falls in a conservation area. Seek consent before manufacture, and send drawings of the window, its sightlines and the rating papers with the application.

How does a Cardiff window job run from survey to fitting?

First come drawings and the class for each window, then the survey takes the size of every opening, each window is built from the written specification, and fitting follows the survey drawings. The first reply brings a cost estimate and the specification in writing, and it arrives inside one working day.

Need rated windows for a Cardiff building? Send opening sizes and the class for each window, and each window will be matched to the risk at that opening.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.