Certified physical security

ArxBridge
Industrial brick buildings with navy steel doors in Sheffield

Blast · ISO 16933 EXV45 to EXV10

Blast Resistant Windows in Sheffield

Blast resistant windows in Sheffield for Meadowhall, hospitals, universities and city centre frontages, rated to ISO 16933 and specified from a site survey.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Sheffield
Prefer to talk?+44 7352 267239

Get a free quote in Sheffield

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Sheffield

What we supply in Sheffield

More on this

ProductBlast resistant windows
First stepSite survey in Sheffield
RatingISO 16933 EXV and SB
ReplyWithin one working day

A blast resistant window holds its glass in the frame when a blast wave strikes it, so the people behind it are not hurt by flying shards. Our blast resistant windows are built as one unit, frame, glass and fixings tested together, and the rating names the blast the unit was tested against. A buyer in Sheffield picks the rating from the threat the site faces, and the survey fixes the size, the wall and the fixing points before the unit is built.

Sheffield gives the work a clear shape. Meadowhall draws large crowds through its entrances, Sheffield station moves people through a busy frontage, and the city centre holds civic buildings, offices and shops behind glazed fronts. Kelham Island mixes workshops, bars and offices in old brick buildings, while the universities and the hospitals hold buildings where glass sits close to public routes. The range of sites is wide, and physical security in Sheffield starts from the building and the people who use it, not from a catalogue size.

Where Sheffield buildings need blast resistant windows first

Meadowhall is the sharpest case in the city. Its entrances face car parks and drop off points where vehicles stop close to the glass, and the frontage runs for long stretches with little solid wall between the panes. A blast unit there needs a frame anchored deep into the structure behind it, because a pane that stays whole is no help if the frame pulls out of the wall. The survey looks at the mullions and the floor slab below each opening, and the specification names the fixing type for each one.

Sheffield station and the city centre ask for a different balance. The station frontage has to stay open and bright for passengers, and the civic and office buildings around the centre need daylight where staff work all day. A solid wall would answer the threat and ruin the building, so the window has to carry the rating while keeping the view, with laminated glass and a frame depth set by the glass build up. Where a listed frontage or a stone surround limits what can change, the survey records the constraint so the design fits the opening as it stands.

Hospitals and universities bring their own demands. The Northern General Hospital and Sheffield Children’s Hospital run wards and treatment rooms where a broken pane would shut a department down, and the glass often sits at ground level beside entrances that the public use all day. The two universities hold lecture theatres, libraries and student rooms with long runs of glazing at street level. In both cases the window must keep its opening lights and cleaning access, so staff can use it and the estates team can reach it. Kelham Island adds older brickwork, where the fixing has to bite into sound material, not into loose mortar.

How the blast rating of a window is proved

A blast rating is a test result, not a thickness. Under ISO 16933 an EXV class is proved by an open air blast from a charge at a set distance, while an SB class is proved in a shock tube at a set peak pressure. The two families answer different questions, so a buyer should ask which one the threat assessment names before choosing a unit. The specification should name the class, the standard and the test record together, so the rating can be checked against the paper that proves it.

The table below puts the four ratings a Sheffield buyer meets most often side by side, with the test behind each one and the place it is usually named.

Rating What it is tested against Where it is usually named
ISO 16933 EXV An open air blast from a charge at a set distance Frontages close to public roads and open space
ISO 16933 SB A shock tube blast at a set peak pressure Enclosed entrances and reception glazing
LPS 1175 SR1 to SR4 A timed hand attack with tools Windows that also need forced entry cover
Fire integrity Heat and flame for a set time Windows set into fire rated walls

A window that must also resist a hand attack is graded on the forced entry scale, although LPS 1175 Issue 8.2 (September 2024) keeps SR1 at class A1 and SR2 at class B3 with a three minute attack time. The two ratings sit on the same unit, and the frame has to pass both tests without one weakening the other. A buyer who needs both should say so at the survey, because a frame built for one threat alone may not hold the other back. The SR classes are listed on our LPS 1175 standard page, and the blast classes are listed on our blast ratings page.

A window set into a fire rated wall needs a fire class too, and a note regarding BS EN 1634-1:2014+A1:2018 shows the test that proves the integrity time for that wall. The fire class is separate from the blast class, and each one needs its own test record. Our guide to blast window cost and specification sets out the questions a buyer should answer before a price is discussed, and the glazed and solid blast doors compared guide covers the choice where a door sits beside a window in the same frontage.

What the survey and the specification cover

The survey is the part of the job that decides whether the window works. The surveyor measures every opening twice, checks the wall build up behind the frame, and notes where the fixing can bite into sound material. At Meadowhall that means checking the slab and the mullion fixings; in a Kelham Island brick building it means finding solid brick behind old plaster; at a hospital it means working around wards that stay open while the survey runs. The surveyor also records the glass build up, the opening lights and the vents, because a unit that cannot be opened or cleaned will be changed by the user, and the change will void the rating.

The written specification then names the rating, the glass build up, the frame section, the fixing type and the test record for each opening, so the buyer can check what is being supplied against what was asked for. A price that names no rating and no test record tells the buyer nothing, and a specification that names both lets the buyer compare two suppliers on the same terms. The work is fitted to the opening, and the handover notes the checks that were run on the day the unit went in.

Send the opening sizes and the rating the site needs to [email protected], and we will answer within one working day and set a survey date. The surveyor measures the opening, checks the wall build up and notes the fixing points before any drawing is started, so the specification that follows it is built on measurements, not on guesswork.

Ask for the test record before you agree a price. A blast rating that cannot be shown on paper is only a claim, and the record is what proves the unit in front of you passed the test named in the specification.

Questions Sheffield buyers ask about blast resistant windows

Do blast resistant windows also stop a forced entry?

Only when the unit carries a forced entry rating as well as a blast rating. The blast test proves the glass stays in the frame under a blast wave, and the forced entry test proves the frame and glass hold back hand tools for a set time. Ask for both ratings in the specification if the site needs both.

Can a blast resistant window be fitted into an existing opening?

Often yes, where the wall behind the frame is sound and the opening can take the deeper frame section. The survey decides this, because a frame anchored into weak brick or a thin panel will not hold the rating. Where the opening cannot take the unit, the specification will say so, and the work may need a new subframe or a rebuilt reveal.

Do blast resistant windows look different from other windows?

From the pavement they look much the same, because the glass is clear and the frame sits in the same opening. Up close the frame is deeper and the sight lines are thicker, since the glass build up and the fixings need more depth than a standard unit. The survey notes the sight lines so the buyer knows what the finished frontage will look like.

What does the survey measure at a Sheffield site?

It measures the opening width and height, the wall build up, the reveal depth and the fixing points, and it records the glass build up, the opening lights and the vents. The surveyor also notes access times and the rooms that must stay open, so the fitting work can be planned around the people who use the building.

Need a blast resistant window in Sheffield? Ask for a quote and send us the opening sizes and the rating the site needs.

Blast resistant glass can be paired with the window where a screen needs the same rating, and blast resistant doors cover the openings beside the glazing.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.