Certified physical security

ArxBridge
Canalside offices with a navy steel entrance door in Birmingham

Blast · ISO 16933 EXV45 to EXV10

Blast Resistant Glass in Birmingham

Blast resistant glass for Birmingham offices, stations and public buildings, rated to ISO 16933 and fitted to a named class for each opening.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Birmingham
Prefer to talk?+44 7352 267239

Get a free quote in Birmingham

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Birmingham

What we supply in Birmingham

More on this

Birmingham puts glass on show. The Bullring frontages, the office towers round Colmore Row, the NEC halls and the terminals at Birmingham Airport all rely on broad glazed areas for daylight and for sightlines between inside and outside. That same glass is the soft spot in a frontage when a blast wave strikes, since shards from a broken pane can hurt people well away from where the blast went off. Blast resistant glass is built to remain seated in its frame when blast pressure hits, so the pane stays whole enough to keep the opening shut.

A single pane never makes a rated window by itself. Pane, frame and the wall round the opening work as one set, and the weakest of the three decides the result. A deep frame fixed firmly keeps the pane seated when load hits, while a shallow frame or a weak wall lets the whole unit give way even when the glass passed a high class test. So the written specification ought to list the glass class, the frame and the fixing together in one place, and the survey ought to note how the wall is built before any pane goes on order.

Birmingham buyers ask for this glass for office receptions, transport buildings, hospitals, universities, hotels and shops with a busy pavement outside. A job might be a single glazed screen in a reception by the Bullring, a run of windows for a public building in the city centre, or a whole facade package for a new building by a station. Every job opens in the same pattern: blast rating put in writing, every opening measured, and frame and fixing matched to the glass. For wider work across the city, our Birmingham area page covers physical security in Birmingham.

ProductRated blast resistant glazing, class named
RatingClass set by ISO 16933 EXV or SB test
UseOffices, transport hubs and public buildings
Reply timeWithin one working day

How blast resistant glass holds together

A blast resistant pane is a laminate: sheets of glass bonded to a tough interlayer. When a blast wave hits, the glass can crack across its face, yet the interlayer keeps the fragments bonded and the pane stays seated in its frame. The rating tests that behaviour. A pane need not stay clear or unmarked after the test; it has to stay in place and keep the opening shut, so that glass and pressure stay outside the room.

Test decides the rating. The blast ratings page runs through the ratings that apply to glazing and to doorsets. The ISO 16933 EXV and SB classes, explained sets out the two routes to a class for a pane. Charge weight and distance fix an EXV class, while a shock tube test fixes an SB class. A specification ought to state the class and give the standard in full, since a pane that passes one class may not pass the other.

Birmingham buildings that order blast resistant glass

The table below names Birmingham sites that often ask for blast resistant glass, with the point each brief has to allow for.

Building in Birmingham What the glass must allow for
City centre offices Broad glazed frontages, reception screens and windows at street level
The NEC and exhibition halls Wide entrance glazing and screens in halls that hold large crowds
Birmingham Airport terminals Glazed frontages and check in areas with constant footfall
Queen Elizabeth Hospital and university buildings Windows and screens on public elevations, with wards and lecture rooms behind them
Bullring and high street retail Shopfront glazing and entrance screens on busy pavements

City centre office blocks often run glazing across the whole ground floor. That glazing shapes how the building looks, and it also takes a blast wave from the street before any other part of the frontage. The blast doors, glazed or solid, compared sets out the pick between glazed and solid doorsets, and why a glazed entrance calls for glass, frame and door leaf rated as one set.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Blast, ballistic and forced entry ratings side by side

Each rating tests one kind of attack. A blast rating tests the pane under a blast wave. A ballistic rating tests it against a bullet of a stated calibre. A forced entry rating tests it against hand tools over a set time. A pane can pass one of these tests and fail another, so naming a single rating where the site needs two leaves a hole that only shows up at test or at attack.

The ballistic ratings page explains the bullet classes, and the LPS 1175 page explains the forced entry grades. The table that runs beneath LPS 1175 Issue 8.2 (September 2024) spells the grades in pairs, starting at the top. D10 pairs with SR4, and C5 pairs with SR3. B3 pairs with SR2, which carries a three minute test time, and A1 pairs with SR1.

Thickness alone tells you nothing about a blast rating. Two panes of equal thickness can sit in different classes, so only the class and the standard named in the test papers show what the pane can take.

Where a site needs blast and ballistic performance together, the two ratings should be set in one specification. The forced entry, ballistic and blast ratings, side by side sets out how the three ratings differ, and the blast resistant windows page shows how the same thinking applies to opening lights and fixed lights.

How to specify blast resistant glass in Birmingham

Start from the elevation, not the catalogue. A street level window on a busy Birmingham road faces a different risk from a window three floors up above a courtyard, and the class should follow that risk. Note the floor, the aspect, how far the glass sits from the pavement or road, and the room behind the glass. That note forms the basis of the rating; keep it with the written specification.

Then fix the practical details: pane size, frame section, finish, manifestation, opening lights where the room needs them, and the cleaning route for the finished unit. A large pane may call for a crane or a suction lifter to get it to the site, and a tight street in the Jewellery Quarter or a basement lightwell can cap the pane size that can be delivered. Note those limits at survey stage, before the order is placed, rather than meeting them on delivery day.

From survey to handover in Birmingham

Every job in Birmingham opens with a visit from a surveyor. That visit sizes each opening, notes how the wall is built and how deep the reveal runs, and flags tight access, such as a tight lane, a basement reached only by stairs, a yard with no vehicle entry, or a site that takes deliveries only outside working hours. From those notes comes a written specification that lists the glass class, the frame, the fixing and the finish, for the buyer to sign off before any order goes in.

Handover closes the job. Test records and care notes reach the buyer together in a single pack.

Frequently asked questions

Does blast resistant glass also stop a bullet?

Not by itself. A blast wave and a bullet are two different tests, so a pane that passes one has not passed the other. One pane can hold both ratings, yet it counts as meeting a rating only where the test papers name that rating in full.

Will blast resistant glass fit my existing Birmingham window frame?

Only if the frame runs deep enough to take the rated pane and holds firm in the wall when blast load hits. Plenty of older Birmingham buildings have frames too shallow for that, so a fresh frame goes in instead. The visit tells you whether the frame already there can stay.

Will people notice blast resistant glass from inside the room?

The pane runs thicker and heavier, and the frame runs deeper, yet from inside the room a well put together unit can pass for plain glazing. The frame edge and the bead give it away. Fix the finish and the manifestation early, at specification stage, so the finished unit fits the building.

What sets the blast rating for a Birmingham office?

The risk at that elevation sets it: the floor, how far the glass sits from the street, and what the room behind the glass is used for. Put the class in writing, with ISO 16933 given in full, ahead of the order. Where the risk is unclear, a consultant can help fix the class.

Ask for a quote for blast resistant glass in Birmingham

Email [email protected] and give each opening size and the rating you need. Expect a reply inside one working day, with the survey date and the order of work after it. Contact ArxBridge to start.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.