Certified physical security

ArxBridge
Canalside offices with a navy steel entrance door in Birmingham

Perimeter and HVM · PAS 68 and IWA 14-1

Security Bollards in Birmingham

Security bollards for Birmingham stations, shops, hospitals and venues, rated to ISO 22343-1:2023, with survey, foundations, fitting and aftercare.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Birmingham
Prefer to talk?+44 7352 267239

Get a free quote in Birmingham

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Birmingham

What we supply in Birmingham

More on this

A busy Birmingham pavement asks for a barrier that stops a vehicle and still lets people through. Bollards outside New Street station, along the Bullring frontage and around Digbeth venues do that job, holding the line while shoppers, workers and visitors pass between them.

Security bollards in Birmingham take fixed, removable and telescopic forms, and the choice turns on the vehicle risk, the pavement width and the way the space is used each day. A fixed line suits a station forecourt, while a telescopic set suits a yard that needs vehicle access at set hours.

The Jewellery Quarter, Aston, the canal side and the NEC each bring their own mix of footfall, deliveries and events. A line that works on a quiet side street would fail on a station approach, so the spacing, the height and the foundation follow the site. The physical security in Birmingham area page maps those uses across the city.

Stations and squaresNew Street station and city squares
RetailBullring, Digbeth and high streets
Health and learningQueen Elizabeth Hospital and University of Birmingham
Events and venuesNEC, arenas and concert halls

Where Birmingham sites need security bollards

New Street station and the squares around it take the heaviest footfall in the city, with crowds moving between trains, trams and shops all day. A fixed line of bollards guards the forecourt edge while leaving wide gaps for people, and the spacing must suit wheelchairs and pushchairs as well as the crowd. The sector page for public spaces walks through the barriers a station and a square use side by side.

Retail streets in the Bullring and Digbeth ask for a line that guards the shopfront without shutting out the shopper. Slim bollards suit a narrow pavement, while a wider frontage can take a heavier line with planting between the posts. The sector page for retail covers the doors, shutters and barriers a shop uses from front to back, and the guide to choosing HVM bollards reads each form against the vehicle risk at the kerb.

Queen Elizabeth Hospital, the University of Birmingham and the venues around the NEC each need a line that fits its own hours. A hospital drop off needs vehicle access for ambulances beside a guarded footway, a campus needs a line that holds through term time, and a venue needs a line that holds a crowd on event nights. The anti ram bollards guide explains how a fixed line is set out and what it is tested to stop.

Ratings that govern security bollards in Birmingham

Vehicle impact comes first in the evidence file. ISO 22343-1:2023 now governs vehicle rated lines. PAS 68:2013 gave way to it in October 2023, as did IWA 14-1, so a new Birmingham line should be specified to the live standard, not to one no longer in force. The vehicle impact ratings page explains the mass, speed and penetration class a rating carries, and the HVM standards guide reads the old and new standards side by side.

Where the same entrance also takes a rated door, the tender places LPS 1175 Issue 8.2 (September 2024) by the vehicle rating in the evidence list, with SR2 as class B3. On the LPS 1175 standard page, each class is shown beside the tools it is tested against, so the door rating on the order matches the risk at that entrance.

Large venues also fall under the tiered duties for public premises. A place that holds 200 to 799 people sits in the standard tier, and a place that holds 800 or more sits in the enhanced tier, with the duties rising with the capacity. Two tiers are named on the Martyn’s Law standard page, and the bollard regulations guide covers the planning and highway rules that run beside the ratings.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Rating guide for Birmingham bollards

Treat the table as a rough pointer only. The vehicle risk at the kerb decides the rating for every line, weighing the mass and speed a vehicle could reach, the distance it could build up and the people behind the line.

Site in Birmingham Bollard form Rating to quote Foundation
Station forecourt, New Street Fixed, slim profile ISO 22343-1:2023 Deep concrete, set out first
Shopping street, Bullring Fixed, slim profile ISO 22343-1:2023 Deep concrete, services checked
Yard entrance, Digbeth Telescopic ISO 22343-1:2023 Sleeve set in concrete
Venue approach, NEC Removable ISO 22343-1:2023 Socket set in concrete
Hospital drop off, Queen Elizabeth Hospital Fixed, wide spacing ISO 22343-1:2023 Deep concrete, access kept clear

How to specify security bollards in Birmingham

Start from the kerb and the way people move. Measure the pavement width, the gap a wheelchair needs and the line a crowd takes, then set the spacing so no vehicle can pass while people flow freely. The PAS 68 bollards guide explains the test behind the older rating, and the bollard foundations guide sets out the depth and the concrete the rating rests on.

Settle the form, the finish and the access together. A telescopic set needs its keys and its lifting weight named in the specification, a removable set needs its sockets and its storage named beside it, and a fixed line needs its colour and its reflective band named for night visibility. The cost factors guide sets out what pushes the price up or down, from the rating to the foundation depth.

Finish with the street and the consent. A line on a public pavement can need highway agreement in addition to any planning consent, and a line near a listed frontage in the Jewellery Quarter can need a further check. The planning permission guide sets out which consent applies, and the traffic calming guide shows how bollards sit beside other measures on the same street.

Project steps for security bollards in Birmingham

The measure comes first, at the kerb itself. The surveyor records the pavement width, the vehicle approach and the underground services, checks the highway boundary, and flags listed status on the older streets of the Jewellery Quarter. Photographs and a measured drawing of every line give the specification a firm base.

The written record then names the rating and the form for every bollard: vehicle rating, spacing, height, finish and foundation depth. Fitting runs in hours agreed with the site, so trading, treatment and events carry on.

At handover the client receives the test evidence for the rating, the O and M manual and the maintenance scope, together with the keys. After handover, routine checks from the maintenance service keep each bollard line working, from the fixings to the telescopic lift. Send the site, the spacing and the rating each line needs to [email protected], or add those details to the quote form instead. Inside one working day you get the written specification, the rating already checked and a budget range in writing.

Check underground services before digging a foundation. Cables and pipes run close under city pavements, and a service found after the dig starts can delay the line and add cost that the specification never allowed for.

Questions about security bollards in Birmingham

What suits a station forecourt, fixed or telescopic bollards?

Fixed bollards suit a forecourt that never needs vehicle access, while telescopic bollards suit a yard or service entrance that opens at set hours. The choice turns on how often a vehicle must pass the line, not on the look of the post.

Do bollards need planning permission?

Sometimes. A line on private land often needs no consent at all, while a line on a public pavement can need highway agreement and, near a listed frontage, a further check. The boundary and the consent are settled before the order goes in.

What rating suits a station forecourt?

The rating follows the vehicle risk at the kerb, with mass, speed and penetration class set for that approach. The current standard is ISO 22343-1:2023, and the rating should be written in the specification with the foundation depth beside it.

How are bollards kept working after fitting?

By the routine visits the maintenance scope sets. Each visit checks the fixings, the finish and, on a telescopic set, the lift and the lock, and any fault found should be put right before the line is left in use.

Planning security bollards for a Birmingham station, shop, hospital or venue? Share the site, the spacing and the rating. The written specification, rating check and budget range arrive with the reply, inside a single working day.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.