Certified physical security

ArxBridge
Business park offices with steel entrances and bollards in Reading

Services

Maintenance in Reading

Maintenance in Reading for hospital, university, station and shop doors, with planned visits, closer and seal checks and a written record each time.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Reading
Prefer to talk?+44 7352 267239

Get a free quote in Reading

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Reading

What we supply in Reading

More on this

A door that is checked on a planned round keeps working the way it was built to work, and a small fault found early stays small. A closer that drags, a hinge that works loose and a seal that has gone hard each change how a door shuts. Maintenance in Reading covers fire doors, security doors, gates and shutters in one round, with each visit written down.

The Royal Berkshire Hospital runs doors that open and shut all day, and a ward door that will not latch is a job for the next visit. The University of Reading runs lecture blocks, libraries and halls where doors take hard daily use, and Reading station runs entrance doors and gates for peak crowds. The Oracle and Broad Street run shopfront and service doors that open early and shut late, and the physical security in Reading page gathers doors, gates and barriers for the town.

A planned round beats a call made after a failure, because a door that has stopped latching leaves a fire compartment open until it is fixed. The visit list is set from the survey of each door, and the fire door maintenance notes set out what a sound round looks like.

Planned visitsVisits set by door use
Closer and hinge checksShut speed, latch and fixings read
Seal and lock checksSeals, latches and locks tested
Written recordEvery fault listed with its date

What a maintenance visit covers in Reading

Each visit opens at the leaf and the frame, reading the gaps and the way the leaf sits when shut. The closer is tested for shut speed and latch, the hinges for loose fixings and wear, and the seals for splits and hard edges. Locks and latches are tested with key and handle, and each fault goes on the visit sheet. The fire door inspection checklist notes list the same checks in order.

The technician works through the door in order. A door that shuts slowly, a leaf that rubs the frame and a latch that needs a push are each noted in plain words, with the fix named beside the fault. Wear parts are listed for replacement, and the sheet is signed off at the door.

Closers, hinges, seals and locks

The closer does the hardest work on a fire door, pulling the leaf shut and holding the latch, and one that leaks oil or loses its pull lets the leaf stand open. Hinges carry the leaf, and one with a loose screw lets the leaf drop and rub the frame, which wears the seal and stops the latch catching. The fire door closers notes cover how a closer is set and read, and the fire door hardware notes cover hinges, latches and locks as one set.

Seals close the gap round the leaf, and one that has gone hard or split lets smoke through and lets the leaf rattle. The gap round the leaf is read at each visit, and the fire door gaps notes give the figures. A lock that turns while the bolt stays put is listed for a new lock, and a latch that misses its keep is listed for adjustment.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Keeping fire and security ratings valid

A Reading service round comforts LPS 1175 Issue 8.2 (September 2024) comforting the buyer with one issue named for each graded door on the list. The LPS 1175 standard page gives the detail behind the grade named on the visit sheet. A1 to H20 is the grade scale, and a tool set and a test time sit behind each grade.

SR1 A1 holds a one minute test time, and SR2 B3 holds three minutes, each against its own named tool set. SR3 C5 holds five minutes and SR4 D10 holds ten, with the grade named in the order beside its tool set. Fire resistance is a separate rating from forced entry, and the fire ratings page names the E, EW and EI classes. A door holds its rating only as built, so a part that no longer matches the tested set is listed for replacement.

PAS 68:2013 is withdrawn. A barrier order today names ISO 22343-1:2023, not PAS 68:2013, for the vehicle impact test. Gates and barriers beside the doors are read on the same round.

Hospital, university, station and shops in Reading

The Royal Berkshire Hospital needs doors that latch first time on wards and clinics, where staff pass through with trolleys and a door that stands open breaks the compartment line. The University of Reading needs lecture block and library doors that take hard use all day, and a hall door that will not latch goes on the sheet the same day.

Reading station needs entrance doors and gates that face crowds at peak times, and a gate that sticks at the morning peak needs a visit, not a note for later. The Oracle and Broad Street need shopfront and service doors that open early and shut late, and Madejski Stadium needs entrance doors that face a matchday crowd and then stand quiet through the week. Station entrances are covered in the transport hub security requirements notes.

Reading site Doors on the round Notes for the visit
Royal Berkshire Hospital Ward, clinic and corridor doors Latch first time, trolley knocks
University of Reading Lecture block, library and hall doors Hard daily use, same-day listing
Reading station Entrance doors and gates Peak crowds, sticking gates at once
The Oracle and Broad Street Shopfront doors and service doors Early opening, late shutting, lock checks
Madejski Stadium Entrance doors and concourse doors Matchday crowds, quiet weeks between

Martyn’s Law and crowded Reading places

From 200 to 799 people a place takes the standard tier duties, and at 800 people or more it takes the enhanced tier duties. The SIA holds oversight for Martyn’s Law, with a spring 2027 start expected. The Martyn’s Law page lists tiers and duties, and the guide for premises notes set out what each tier should plan.

Reading station and the Oracle hold the largest crowds in the town on a busy day, and a university hall or a hospital entrance holds a smaller crowd in the standard tier. Visits at a crowded place are timed round the crowd, so the doors are read while the place is quiet, and the tier is filed before the round is set.

Planned visits, repair visits and honest limits

A planned visit is set by how hard the door is used, so a hospital corridor door is read more often than a store room one. A repair visit is booked when a door will not latch, a closer leaks oil, a lock turns while the bolt stays put, or a seal has come away. The sheet names which one it is, so the buyer knows whether the call is a planned check or a fix.

A maintenance visit does not refinish a leaf, and paint or powder coat is a separate job. Where a leaf is split or a frame is bent, the work is a repair, and we do not repair leaves or frames that need a joiner or a steel worker. The fault is written up with the trade it needs.

Survey, specification and reply in one working day

Each door is read in the survey before a visit round is set, with rating, use and wear noted. The written specification names the doors, the checks and the visit pattern, and wear parts are supplied to match the list. The how to specify security doors notes cover the write-up, and a reply lands in one working day.

The service record closes on the chapter Saffron Road, Romford, Essex RM5 3ES. Forward tomorrow with the door list in hand, and the first visit starts at the hospital doors.

Email [email protected] for maintenance notes on the Reading doors, and the reply names the next visit date. The SR2 fire doors in Reading listing covers the graded fire doors on the round, and the security doors in Reading listing covers the security doors at the same entrances.

A door checked on a planned round rarely fails without warning, so the visit sheet is the cheapest part of the door.

Questions from Reading buyers about maintenance

How often should a fire door in Reading be checked?

The round is set by use. Doors in constant use, such as hospital corridor doors and station entrance doors, are read more often than a door in a quiet store room.

What is covered on a maintenance visit?

A visit covers leaf, frame, gaps, closer, hinges, seals, locks and latches. Each fault goes on the sheet with its door, and the sheet is signed off at the door.

Does maintenance keep the fire rating valid?

A visit checks the door against the rating it was built to, and any part that no longer matches is listed for replacement. The rating rests on the door as built, so a worn part is fixed before it breaks the rating.

What if a door needs repair, not maintenance?

When a leaf has split or a frame has bent, the job counts as a repair, and we do not take on repairs that need a joiner or a steel worker. The visit sheet names the trade it needs.

Plan the maintenance round for your Reading doors

Share the door list and the use of each door, and the quote covers survey, visits and file. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.