Certified physical security

ArxBridge
Sandstone and glass offices with a steel entrance door in Leeds

Services

Maintenance in Leeds

Maintenance in Leeds for security doors, frames and hardware, with rounds that check each leaf, closer and lock and keep the tested rating valid.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Leeds
Prefer to talk?+44 7352 267239

Get a free quote in Leeds

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Leeds

What we supply in Leeds

More on this

Maintenance in Leeds keeps security doors, frames, screens and hardware working as they were tested, through rounds that check each leaf, each closer and each lock in turn. Dragging doors, slamming closers and sticking locks each point to wear that a round can catch early, before the leaf stops shutting as it must.

Leeds gives those rounds a wide range of buildings. Leeds General Infirmary runs wards through the day and night, the University of Leeds fills lecture halls and labs in term time, and Leeds station moves passengers from early morning to late night. Elland Road and Headingley Stadium bring match day crowds, while Trinity Leeds and Kirkgate Market keep shopfronts busy through the week. Our page on physical security in Leeds gives the wider picture for the city.

Each rating on the round appeals LPS 1175 Issue 8.2 (September 2024) branching the attack time beside the leaf in the visit record. Any change to leaf, frame or hardware is then judged against the tested set. A door rated SR2, or B3, resists attack for 3 minutes under that standard, and a worn closer or a loose fixing can take a leaf outside the set that was tested. The LPS 1175 page lists the levels and the attack times behind them.

Rounds plannedVisit dates set round wards, lectures and match days
Every leaf checkedLeaf, closer, lock, hinges and seals checked in turn
Worn parts swappedHinges, seals and keeps replaced before they fail
Record keptEach visit logged with the leaf, the fault and the fix

What a maintenance round covers

The round starts at the first leaf on the list and works through the building in order, so no leaf is missed and the visit record follows the same order as the last round. The leaf list is agreed with the site manager before the round starts. Each leaf is opened and shut, each closer is watched through its arc, each lock is thrown and withdrawn, and each hinge is checked for play.

The checks go wider than the moving parts. Gaps round the leaf are read, seals are checked for splits and gaps, thresholds are checked for wear, and fixings are checked for looseness where the frame meets the wall. Dragging leaves, split seals and loose hinges are all noted on the spot, with the leaf, the fault and the fix written into the visit record. Our guide to fire door upkeep covers the same checks for fire leaves, and the inspection list guide gives the order to follow.

Keeping the rating valid

A rating only holds where the leaf, the frame and the hardware match the tested set. Swap a closer for a different model, change a lock for a different throw or fit a hinge of a different size, and the set on the wall no longer matches the set that was tested. The round judges every change against the test record, and a part that does not match is flagged for a like for like replacement. The fire side of the same rule is on the fire ratings page, and SR2 fire doors carry a fire rating beside their forced entry rating on one leaf.

Fire door checks sit inside every round. Gaps round the leaf, the state of the seals, the action of the closer, the throw of the latch and the fix of the hinges are all read and noted, and a leaf that will not shut fully is treated as the first fault to fix. The hospital rules guide covers the checks that apply on ward and corridor leaves, where a door that fails to shut puts the ward at risk.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

Rounds for Leeds buildings

Building Round focus Notes
Hospital wards Closers, latches and seals on ward and corridor leaves Planned round ward hours
Campus Lecture hall and lab leaves, hinges and access hardware Planned round term dates
Station and retail Concourse screens and shopfront leaves Planned round trading hours
Stadiums Gates and concourse leaves before match days Planned round the fixture list

The table sets the order for each round. A ward round starts with the corridor leaves that see the most use, a campus round starts with the lecture halls that fill first, and a stadium round starts with the concourse leaves that take the match day flow. In each case the visit record follows the same order, which lets the next round pick up a fault noted before without delay. A fault noted on one round is checked again on the next, so a repair that has not held is caught while the leaf is still on the list.

Log every change to a leaf, a lock or a closer. A part swapped without a note can leave the next round judging a set that no longer matches its test record.

Hospital wards, campus and concourse

Leeds General Infirmary sets the hardest test for a round. Ward doors move beds and trolleys all day, corridor leaves are pushed open a hundred times a shift, and a closer that has lost its pull shows up fast in a ward that never sleeps. The round checks those leaves first, with dust sheets down and the corridor kept clear, and any leaf that will not shut is made safe on the day.

On the University of Leeds campus, lecture hall and lab leaves take a different kind of wear, with classes filling and emptying through the day and access hardware worked hard between sessions. Our guide to campus doors covers teaching rooms and labs. At Leeds station and in Trinity Leeds and Kirkgate Market, concourse screens and shopfront leaves face constant use, and at Elland Road and Headingley Stadium the gates and concourse leaves are checked before match days. Sliding vehicle gates in Leeds are checked on the same round where a site has them, and security doors in Leeds are checked leaf by leaf. Where a leaf is past repair, fitting work replaces it with a leaf made to the same schedule.

Send worn parts to our gallery Saffron Road, Romford, Essex RM5 3ES call during office hours first, so the parcel lands with the team that handles spares. Email [email protected] for surveys of your doors, with the leaf count and the faults you have seen. Ask for a round date that suits the building when you email us.

Frequently asked questions

How often should a security door be checked?

It depends on how hard the leaf is used. A leaf in constant use is checked more often than a leaf on a quiet store room, and the programme is agreed with the site manager at the first visit. Busy corridor leaves, ward doors and concourse screens sit at the front of every round.

What is checked on a fire door?

The gaps round the leaf, the state of the seals, the action of the closer, the throw of the latch and the fix of the hinges. A leaf that will not shut fully, a split seal or a slamming closer is noted as a fault and fixed before the next round.

Does a repair change the rating?

A like for like part keeps the set as tested, while a different model of lock, closer or hinge needs to be checked against the test record before it is fitted. The visit record notes the part that was fitted, so the next round judges the set that is actually on the wall.

What happens when a fault is found on a round?

The fault is noted with the leaf, the part and the fix it needs, and the leaf is made safe on the day where it will not shut or latch. The part is ordered, the revisit is agreed with the site manager, and the fix is written into the visit record once it is done.

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.