Security · LPS 1175 SR2 to SR5
Security Windows in London
Security windows in London for schools, offices, flats and hospitals. EN 1627 RC classes, frames and glazing explained, with a quote in one working day.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in London
Get a free quote in London
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in London
What we supply in London
Security windows in London guard the glazed openings that burglars and intruders test first: ground floor windows, basement lights, rear windows behind gardens and side windows beside a door. A window of this kind pairs a strong frame with laminated glass and tested hardware, so the pane stays in its frame when forced and the lock holds when the handle is attacked. Victorian terraces in Islington and Clapham, mansion blocks in Kensington and Maida Vale, schools in Croydon and Barnet, and offices in the Square Mile all hold windows of this kind.
London housing and workplaces put windows under daily pressure. Ground floor flats face pavements and alleyways, school halls and classrooms face playgrounds and streets, hospital wards face courtyards open to the public, and office windows at street level face roads where footfall stays high late into the evening. The class for each window follows the risk at that opening, and the frame, glass, hinges and locks are judged as one tested unit. For other rated work across the capital, see physical security in London.
Where London puts security windows first
Flats and houses put them at ground level. Basement lights, rear windows behind gardens, side windows beside a front door and windows over a flat roof are the openings an intruder reaches first, so each one needs a frame and a lock that resist levering. The residential sector page describes how a home zones its windows, doors and side gates.
Schools and colleges use them at halls, classrooms and entrances. Glazed entrance screens, ground floor classrooms and sports hall windows in Croydon, Barnet, Ealing and Greenwich face playgrounds and streets where large numbers of children gather, and the glass must hold when struck while still letting in daylight. The security windows for schools guide covers how a school plan treats entrance glazing, halls and classrooms, and the education sector page sets out how a school estate is zoned.
Offices, hospitals and public venues form the third group. Street level offices in the Square Mile and Canary Wharf, wards and entrance halls along the Thames, and the concourses at Waterloo and Victoria all hold large areas of glass where staff and the public mix. Windows on those elevations must resist forced entry and still open for ventilation where the room needs fresh air, and the window security bars guide weighs bars against a rated window where a stronger barrier is wanted.
How a window rating works
One rating covers the full window, never the pane on its own. Glass, frame, beads, hinges, locks and fixings passed testing as one assembly, so replacing any single part after the test can strip the rating of support. EN 1627 gives the resistance classes for windows, from RC1 to RC6, and every class states the tools and the time the window must resist. The September 2024 LPS 1175 Issue 8.2 sets the SR classes from SR1 to SR5 for doors and shutters, and the two scales are often quoted side by side on a London schedule.
Most London homes and schools sit at RC2 or RC3, while cash offices, server rooms and high value stores ask for RC4 or higher. A risk assessment for the opening fixes the class. It should name the room behind the window, the height above the ground and the tools an intruder could bring. The LPS 1175 windows and walling guide takes up the forced entry side, and the LPS 1175 standard page gives each class in turn.
Laminated glass is the heart of a rated window. Two or more panes bonded with an interlayer stay in the frame when cracked, so the opening stays shut even after the glass breaks. The frame must match the pane: a tough pane in a poor frame puts the pressure on the fixings, and a strong frame around a weak pane still leaves a way through. Ratings do not swap between threat types, as that forced entry, ballistic and blast ratings page shows.
Rating guide for London windows
Let the table serve as a rough guide only. The risk assessment for the opening fixes the final class for each window, and the consultant signs it off with the site security team before a price is quoted.
| Site in London | Opening | Rating to quote | Glazing type |
|---|---|---|---|
| Flats and houses | Ground floor and basement windows | EN 1627 RC2 or RC3 | Laminated pane in a steel or uPVC frame |
| Schools and colleges | Halls, classrooms and entrance screens | EN 1627 RC2 or RC3 | Glazed screen with a rated frame |
| Offices and hospitals | Street level windows and ward glazing | EN 1627 RC3 or RC4 | Window with tested locks and hinges |
| Cash offices and server rooms | Windows beside high value rooms | EN 1627 RC4, per the assessment | Heavy pane with a steel frame |
| Stations and venues | Concourse and public elevation glazing | EN 1627 RC3, per the assessment | Window matched to the door beside it |
Specifying a security window in London
Open with the risk at the opening. Name the room behind it, the height above the ground, the opening method and the ventilation the room needs, then set the RC class from EN 1627. The how to specify security doors guide describes what to settle before pricing, and the fire rated windows guide covers the fire side for a window that must also hold back fire.
List the pane, frame, beads, hinges, locks and fixings as one tested unit in the specification, and attach the test evidence for the quoted class to the specification. The finish, the cleaning access and the restrictor go in as well, so the window stays usable and safe where children use the room. Where the glass also needs a security glazing class, LPS 1270 Issue 1.1 (2014) covers it, and the LPS 1270 standard page lists its classes.
Before any replacement, consent is needed for work on a listed building or a building in a conservation area. Drawings of the window as proposed, showing its sightlines and the rating evidence, go with the application, and consent has to come before manufacture. The two consents sit apart from planning permission, and the order is consent first, then manufacture, then the fitting itself.
Survey to fitted window in London
A London window job opens with drawings or a schedule giving the class for each window. At the premises, the survey records the size of every opening, checks the wall build, the reveal and the sill level, and notes how the room is used each day and the way each window opens. Those measurements fix the size and the fixing method of each window, so each one is made to the sizes taken at the survey. That counts in older London buildings, where openings seldom match.
Each window is built to the written specification. The evidence for the quoted class goes with it. Fitting falls within the installation service. That maintenance contract scope for doors and barriers page sets out the checks that keep every rated window working well once handover is done.
Email the drawings and the class for each window to [email protected]. Those same details go on the quote form too. The reply arrives the following working day, holding a cost estimate with a check on the class, and the specification in writing too.
Windows, frames and finishes for London buildings
Give the class each window needs, and the size of its opening, in the enquiry. A window taken from another building rarely fits a London opening, so put both figures first, and the specification is built from them.
Questions about security windows in London
Which RC class fits a ground floor flat in Islington?
The assessment for the opening decides it. RC2 or RC3 is the usual range for a ground floor window, once the room behind it, the height above the ground and the tools an intruder could bring are known.
Can a security window still open for fresh air?
Yes, where the opening method and the restrictor passed testing with the rest of the unit. Name the opening method and the restrictor in the specification, and attach the test evidence for the quoted class to the same file.
Do listed buildings in Kensington need consent for a new window?
Yes, where the building is listed or the street sits in a conservation area. Get consent before manufacture, and the application needs drawings of the window, its sightlines and its rating evidence.
How does a London window project run from survey to fitting?
The window job opens with drawings and the class for each window, the survey records the size of every opening on site, each window follows the written specification, and work at the building sticks to the drawings handed over at survey. The first reply, sending the specification in writing and a cost estimate, arrives the following working day.
Need security windows on a London building? Send over the drawings and the class each window needs, and a tested window will be chosen for every opening.
Other areas
Security windows in other areas
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.