Certified physical security

ArxBridge
Glass and brick offices with steel entrance doors and bollards in London

Shielding · EMP, RF and MRI

Electromagnetic and RF shielding in London

Electromagnetic and RF shielding in London for data centres, hospitals and research rooms, measured in dB attenuation, with sealed rooms and a written quote.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in London
Prefer to talk?+44 7352 267239

Get a free quote in London

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in London

What we supply in London

More on this

A buyer in London who needs a shielded room starts with the signals that must stay out, because a data centre, an MRI suite and a research laboratory each fail in a different way when stray signals get through. Electromagnetic and RF shielding in London covers rooms where equipment must work without interference and where sensitive signals must not leak out. The room is only finished when the test shows the attenuation the specification asked for.

The City and Canary Wharf hold data centres and trading floors where shielding keeps equipment steady through the working day. Hospitals across central London hold MRI suites where the shielded room keeps outside signals away from the scanner. London universities hold laboratories where a shielded room keeps test signals clean.

A survey of the room opens the job, covering the walls, the door, the vents and the cable entries. The written specification that follows names the shielding target in dB beside each surface, and electromagnetic and RF shielding in London is ordered on the strength of that document. For the wider range in the same city, the physical security in London page brings doors, gates, barriers and shielding together.

MeasureAttenuation in dB across the band
RoomData centre, MRI suite or laboratory
SealDoors, vents and cable entries sealed
ReplyWritten answer in one working day

What shielding does in a London room

Shielding puts a conductive layer around a room so that radio signals lose strength as they cross it, and the loss is written as attenuation in decibels. A higher figure means less signal gets through, and the figure is quoted across a band of frequencies rather than at one point. The specification names the band and the target in dB, and the room is tested after the build with the door shut and the vents in place.

A data centre in the City or at Canary Wharf needs shielding where racks stand in tight rows and a stray signal can upset the equipment beside them. A trading floor needs the same steady conditions through the working day. For the zones inside a data centre, the guide to physical security by zone maps each one, and the cage against a built room comparison draws the line between the two.

Government buildings hold rooms where signals must not leave the building at all. Under Martyns Law, premises with 200 to 799 people count as standard tier, and premises with 800 or more count as enhanced tier. Oversight of the scheme sits with the Security Industry Authority, with a start expected in spring 2027, and the Martyns Law guide for premises lays out what each tier asks of a site, and the Martyns Law standard page carries the tier detail.

LPS 1175 grades are not shielding ratings

Any buyer deals LPS 1175 Issue 8.2 (September 2024) dealing with forced entry, while shielding is measured in dB attenuation and never in forced-entry minutes. The scale runs from A1 to H20, and the hold time rises with the tool set: A1 and SR1 give one minute, B3 and SR2 three, C5 and SR3 five, and D10 and SR4 ten. Heavier tool sets earn the longer times. The guide that specifies an LPS 1175 door in ten steps makes the grade into an order, and the LPS 1175 standard page prints the grade table in full.

That grade answers how long a door or a shutter holds against tools, and it says nothing about how much radio signal passes through a wall. A shielded room can carry a high LPS 1175 grade on its door and still leak signals through a vent. The two measures sit side by side in the specification, and neither one stands in for the other. A buyer who reads a grade as a shielding figure will order the wrong room, so the written specification keeps the two measures apart.

Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

London rooms and the shielding each one needs

London room Shielding Room notes
Data centre in the City Shielded walls and door, tested across the band Racks sit close together and stray signals disturb the equipment beside them
Data centre at Canary Wharf Shielded room for trading floors and server halls Figure must hold while staff pass in and out all day
MRI suite in a hospital Shielded room around the scanner, door sealed at every edge Outside signals must stay away from the scanner during a scan
Research laboratory Shielded room for test benches and measurement rigs Test signals must stay clean enough to trust
Government room Shielded walls, door and cable entries, tested after the build Signals must not leave the building at all

Five London rooms appear in the table, each with its shielding and the notes behind the choice.

Doors, vents and cable entries: where shielding leaks

A shielded room leaks at its openings, and the door is the largest of them. The door takes a conductive seal around every edge, with the leaf pressed tight against the frame when it shuts. Where a shielded door also carries a fire rating, BS EN 1634-1:2014+A1:2018 fixes the class as E, EW or EI, with the time running from 30 to 120 minutes, and each band appears on the fire ratings page.

Vents take a shielded grille that lets air through and blocks signals, and the grille is sized from the air the room needs rather than from the hole in the wall. Cable entries take a filtered penetration, with each cable passing through a filter that stops signals travelling along it, and a spare entry is capped rather than left open. A room with a sealed door and an open cable entry leaks at the entry, and the test after the build finds it at once. The EMP shielding cost factors guide lists the parts behind the written quote, and EMP shielding in London covers the related work for a London site.

Seams in the wall lining are taped and pressed flat, and each joint is checked before the next layer goes on, because a gap under a skirting board leaks as surely as a gap in the door. Security doors in London cover the entrance doors that stand beside a shielded room, and the test report after the build lists the attenuation at each frequency in the band, with the door shut and the vents in place.

Survey, target and fitting

Five stages carry the job: a survey, a target, a written specification, supply, then fitting with testing. The room is measured on the survey, with the walls, the door, the vents and the cable entries noted down at the time. The specification then lists the build, the seals and the test. A room that needs a new door or a new vent is priced on its own line.

Email [email protected] after discussing the room size and the shielding target with your team, and a written reply gives the London scope and the next step.

Send the room drawings and the test notes to the claim Saffron Road, Romford, Essex RM5 3ES. Call again once the drawings are ready, and the visit date can be set there and then.

Get the attenuation target in dB, the test band and the test report down in writing before ordering, and match each one to the room once fitted.

London buyers ask about electromagnetic and RF shielding

How is shielding measured?

Shielding is measured as attenuation in decibels across a band of frequencies, with a higher figure meaning less signal gets through. The test runs after the build with the door shut and the vents in place, and the report lists the figure at each frequency in the band.

Is shielding measured by an LPS 1175 grade?

No. LPS 1175 grades a door or a shutter against forced entry, with time allowed from one minute at A1 and SR1 to ten minutes at D10 and SR4. Shielding is measured in dB attenuation, and the two measures sit side by side in the specification.

Can shielding go into an existing London room?

Yes, in most cases. The survey records the walls, the door, the vents and the cable entries, and the specification lists the lining, the seals and the filtered penetrations the room needs. A room with a sound structure takes the lining inside, and the test after the build proves the figure.

When will the written quote for a London room arrive?

The survey records the room and the openings. A written specification follows that visit, with the reply back in one working day.

Plan the shielding for your London room

Send the room size with the shielding target. The written quote lists the build, the seals and the test. Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.