Certified physical security

ArxBridge
Laminated glass security screen and steel door in a secure UK reception

Ballistic · EN 1522 FB2 to FB7

Bullet resistant windows in Coventry

Bullet resistant windows for Coventry receptions, ticket desks and gatehouses, rated BR1 to BR7 plus SG1 and SG2 and fitted to a written specification.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in Coventry
Prefer to talk?+44 7352 267239

Get a free quote in Coventry

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in Coventry

What we supply in Coventry

More on this

A bullet resistant window at a Coventry site has to stop a round and stay in its frame. It has to keep the room behind it safe, keep the view clear enough for staff to see who stands outside, and still open and shut on an ordinary working day. A window at a council reception, a window at a university security office and a window at a depot gatehouse all face the same test, yet each one needs a different glass thickness, a different frame and a different way to fix the glass into the opening. bullet resistant windows from ArxBridge are made from measurements taken at each opening, so the window meets the frame squarely and the fixings carry the load the rating asks for.

Coventry gives a bullet resistant window plenty of places to work. Coventry City Council buildings hold receptions where staff meet the public face to face, security offices and cash rooms at the two Coventry universities sit behind glazed screens, while pharmacies and reception desks at University Hospital Coventry keep staff behind glass through the day. Coventry Building Society Arena holds ticket offices and control rooms, Coventry railway station holds booking offices beside passenger routes, and Jaguar Land Rover sites hold gatehouses and control rooms on the edge of the city. Ticket desks and cash points at the Herbert, the Belgrade and the transport museum use a glazed screen that keeps staff safe while visitors still feel welcome.

Ordering starts with a visit to measure each opening, after which the buyer agrees the class on paper and receives a specification that lists the pane thickness, the opening size, the frame section and the fixings. A window that looks right on paper can still fail if the frame cannot hold it, so the frame, the fixings and the glass are specified as one system. A buyer can compare the three kinds of rating in the guide that contrasts forced entry, ballistic and blast protection, while the ballistic ratings page shows every class that can be named on an order.

Window typesFixed, opening and sliding windows
RatingsBR1 to BR7 and SG1, SG2
FrameSteel frame made to the opening
Reply timeOne working day

Where Coventry sites put a bullet resistant window

Receptions put the most demand on a window. At a council reception, staff meet visitors face to face through a screen that has to stop a round and still let voices pass clearly. At University Hospital Coventry, pharmacy counters and reception desks sit behind glass where staff handle medicines and records, and a window that stays in its frame keeps the staff safe without shutting the patient out. University security offices and cash handling rooms use glazed screens where staff count cash or watch monitors.

Ticket offices and gatehouses use bullet resistant windows in a quieter way. At the arena, ticket windows and control rooms sit beside crowd routes, and the window there has to stay clear enough for staff to see the queue while it holds against a round. Coventry railway station booking offices sit beside passenger routes, and a window there has to carry the noise of the concourse without losing its rating. Gatehouses at Jaguar Land Rover sites and ticket desks at the Herbert, the Belgrade and the transport museum all use glazed screens where staff take cash.

Ratings that decide the window

The rating to name first comes from EN 1063. The BR1 to BR7 classes cover handgun and rifle rounds, and the SG1 and SG2 classes cover shotgun rounds, and the guide to ballistic glass ratings sets out each class with the round it was tested against. The frame and the fixings carry a rating of their own under EN 1522 and EN 1523, with FB1 to FB7 classes for the window and FSG for shotgun, and the ballistic ratings page pairs every class with the test behind it. Naming the class on the order gives the buyer a named test to check the fitted window against.

Choose the class from what the site faces, not from how big the window happens to be. The guide to choosing a ballistic rating sets out how to match the class to the risk, and the bullet resistant glass cost guide lists the items that push a window price up or down. Where a window also has to hold against forced entry, the written specification prefers LPS 1175 Issue 8.2 (September 2024) matching the tool sets the window, the frame and the fixings were tested against. SR1 to SR4 mark the LPS 1175 scale, and the upkeep guide for an LPS 1175 rating explains the checks that keep the rating good after fitting.

Window Where it fits Rating to name
Fixed reception window Council and hospital receptions BR4 or BR5
Opening security window University security offices BR2 or BR3
Sliding ticket window Arena and museum ticket desks BR2
Gatehouse window Depot and factory gatehouses BR3 or BR4
Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

What the survey pins down before a price is given

A good survey looks past the first year and asks how the window will stand up after two winters of daily use. It notes the clear opening, the depth of the reveal, the condition of the wall the frame fixes into, how the window opens and how people use the room day to day. A window at a hospital pharmacy that serves staff through the day needs a different duty from a window at an arena ticket office that serves a crowd on event nights, and the glass thickness, the interlayer and the fixings follow from that use. The how to specify guide lists the points to agree on paper before an order is placed, and the lead times guide gives the span from survey to fitting for an order.

With the survey sizes agreed, the frame and the window are built to those measurements and the drawing marks where each fixing goes. A bullet resistant glass pane beside the window is worth agreeing at this stage, because the glass and the window then share one frame detail and one rating. The specification drawn up next names the rating, the pane thickness, the opening size, the fixings and the finish, and the buyer keeps that document as the signed record of the job.

Get the class confirmed on paper ahead of ordering. A window sold merely as strong gives the buyer no named test to point to once the work is checked.

Fitting, handover and care

Fitting is timed so the site can carry on while the work happens. A window at a hospital reception goes in during a slot fixed with the site manager, the old window comes out only once the new frame is ready to take the glass, and the fixings, the seals and the locks are checked as one before handover. The Coventry order is priced from the Romford unit: Saffron Road, Romford, Essex RM5 3ES. The handover pack carries the specification, the window sizes and the maintenance notes.

After fitting, the window needs little more than a regular check. Check the seals for gaps, watch the opening gear for smooth travel, and look at the frame fixings for loosening where the window takes daily use. A window that has taken a knock is checked at once, even if the glass looks sound, because the interlayer can carry damage the eye cannot see. The handover pack notes say how often each check falls due.

Questions from Coventry buyers

What thickness of bullet resistant glass does a reception window need?

It follows the rating, not the room. BR2 suits most receptions that hold cash and records, and BR4 fits where the risk runs higher. The guide to ballistic glass ratings sets out each class, and the written specification names the class the site needs.

Can a bullet resistant window open, or must it stay fixed?

It can open. An opening window carries the same glass rating as a fixed one, and the frame, the hinges and the lock carry the rating with it. The survey decides the point by measuring the opening and the wall behind it, and a sliding window suits a ticket desk where staff pass items through a tray.

Does a bullet resistant window stop a forced entry too?

Not on its own. A ballistic rating tests the glass against rounds, and a forced entry rating tests the window, the frame and the fixings against tools. One opening can carry both risks, so the specification lists a ballistic class and a forced entry class side by side, with LPS 1175 classes running from SR1 to SR4.

How long does a bullet resistant window order take from survey to fitting?

Expect a reply to the enquiry inside one working day. Once the survey is done the specification is drawn up, and a fitting date is fixed when the sizes are confirmed and production is under way.

For a price on the windows, write to [email protected], simply send the opening list, and the team sends a written reply inside one working day, giving the glass thickness, the frame detail and the price for the job.

Request your free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.