Certified physical security

ArxBridge
Glass and brick offices with steel entrance doors and bollards in London

Ballistic · EN 1522 FB2 to FB7

Bullet Resistant Windows in London

Bullet resistant windows for London banks, embassies, jewellers and control rooms, with FB and BR ratings, tested frames and a written specification.

  • ✓Third-party test evidence with every product
  • ✓Written specification you can issue to tender
  • ✓Supplied and installed in London
Prefer to talk?+44 7352 267239

Get a free quote in London

Rating, written specification and budget range within one working day.

ArxBridge Quote Form

Confidential. No cost, no obligation.

Third-party tested

Evidence with every quote

UK manufactured

Made to your sizes

One accountable team

Specify, supply, install

Confidential handling

Details never shared

Supplied and installed in London

What we supply in London

More on this

A street facing window in London can be the weakest point in an otherwise guarded building. Banks and cash offices in the City, embassies in Westminster, jewellers in Hatton Garden and Mayfair, and control rooms in Canary Wharf towers all hold people and high value material behind glass, and a threat assessment that identifies a firearms risk points straight at the glazing and the frame around it.

Bullet resistant windows answer that risk as a tested assembly, not as a thicker pane fitted into an ordinary frame. The glazing, the frame, the fixing into the wall, and the seals work as one unit, and the rating applies to the whole window. A strong pane in a weak frame leaves the opening open, so the specification names the class for the glazing and the frame together.

London brings a wide range of openings to that specification, from a ground floor reception in a tower to a cash room window, a jeweller shopfront, and a laboratory window in a teaching hospital. The right window for each one follows the risk at that opening, the size of the pane, and the way the room is used day to day.

Banks and cash roomsCity branches, cash offices and trading floors
Embassies and governmentWestminster offices and diplomatic premises
Jewellers and high value retailHatton Garden, Mayfair and Bond Street shops
Control rooms and hospitalsCanary Wharf towers and teaching hospitals

Where London buildings need bullet resistant windows

Westminster and Whitehall hold the clearest case: offices of government and diplomatic missions there put street facing rooms and reception glazing within easy sight of passers by, and the schedule for such buildings often pairs ballistic glazing with forced entry protection on doors and service entries. The London area page describes the zoning of those estates across the capital.

Bank branches, cash offices, and trading floors in the City and Canary Wharf need glazing that holds its line while staff move money and work at desks close to the glass. A cash room window, a counter screen, and a ground floor meeting room each carry a different exposure, and the rating is set opening by opening. Bullet resistant glass explains the glazing classes that sit behind those choices.

High value retail in Mayfair, Bond Street, and Hatton Garden faces a different pattern. Jewellers, watch dealers, and pawnbrokers hold stock in window displays and in back rooms, and the window must resist attack long enough for staff to reach a safe area and for help to arrive. A fixed pane with a tested frame suits a display, while a service window at the rear of the shop may need an opening light with locks that hold the same rating when shut.

Ratings that govern bullet resistant windows in London

Two linked standards set the ballistic ratings for a window. BS EN 1522, with its test method in BS EN 1523, both from 1999, grade the complete window against named firearms and ammunition, and BS EN 1063 (2000) grades the glazing on its own. The ballistic ratings page covers both scales, and the choosing a ballistic rating guide explains how a threat assessment picks a class.

The frame must be graded to match the glazing, never below it. A BR4 pane in an ungraded frame has no tested rating as a window, and a buyer should ask for test evidence for the full assembly, with the FB class, the BR class, the frame material, and the fixing method all named in the same document. Security glazing itself is graded under LPS 1270 Issue 1.1 (2014). The forced entry side of the same opening is covered by LPS 1175 Issue 8.2, dated September 2024. A window that faces both a firearms risk and a forced entry risk should carry test evidence under each standard it claims.

Spall, light, and weight shape the final choice. Some glazing throws fragments from its rear face when struck, so the specification should state whether a spall shield is fitted, and thicker glazing cuts light and adds weight, which changes the frame section and the wall fixing. The ballistic glass ratings BR1 to BR7 guide explains the glass classes, and bullet resistant versus bulletproof glass clears up the wording buyers meet in sales material.

London use Opening Rating to ask for Window form
Bank branch Cash room and counter FB3 to FB4, BR3 to BR4 glass Fixed pane, tested frame
Embassy or government office Street facing rooms FB4 to FB6, BR4 to BR6 glass Fixed pane, spall shield
Jeweller shopfront Display and rear service window FB3 to FB4, BR3 to BR4 glass Fixed display, locked opening light
Control room View over concourse or yard FB2 to FB4, BR2 to BR4 glass Fixed pane, clear sight line
Hospital or laboratory Pharmacy and laboratory windows FB2 to FB3, BR2 to BR3 glass Fixed pane, LPS 1175 frame
Need this specified for your project?Free rating, written specification and budget range within one working day.
Get a free quote

How to specify bullet resistant windows in London

Start with the threat assessment, not with a catalogue class. The assessment names the weapon types the building must resist, the distance of the likely firing point, and the time staff need to reach safety. That note fixes the FB class for the window and the BR class for the glass, and every later choice follows from it. A class copied from another building in another street rarely fits, because the street, the pavement width, and the room use are never the same.

Next, settle the frame and the fixing. Steel frames carry the heaviest glazing and suit deep reveals in older London buildings, while aluminium frames suit lighter classes and modern curtain walling. The frame section, the bead, the gasket, and the anchor into brick, stone, or concrete should come with the same test evidence as the glass, and the survey should check the wall around each opening before the sizes are fixed. The LPS 1175 windows and walling guide explains how the wall and the window are tested as a pair.

Then settle the daily use of the room. A fixed pane suits a display or a control room, while an office or a laboratory may need an opening light for air, with locks and hinges that hold the rating when shut. Listed buildings in central London add a consent step, because a change to a facade in a conservation area or to a listed building needs Listed Building Consent before work starts. Bullet resistant doors beside the window should carry a matching class, so the door does not become the easy route in.

Project steps for bullet resistant windows in London

Work begins at the window itself, with a survey of every opening. The surveyor records pane size, reveal depth, wall material, and how delivery and fitting will reach the window, and notes listed status and any alarm wiring nearby. Drawings or photographs marked with the rating each opening needs give the specification a solid starting point.

Next, the rating goes into writing: FB class, BR class, frame material, spall treatment, and fixing method, named opening by opening. The security consultancy service takes a threat assessment and writes it up as that specification, and the security windows range holds the product forms that specification can draw on. Evidence for the rated assembly is handed over with the windows, so the buyer can compare the class claimed with the class actually tested.

Supply is cut to the sizes the survey recorded. The order, done by our own team or by our installation partners, runs from the written specification and the surveyed sizes. Work is timed to fit the building’s working hours where the programme allows it. To start, post drawings marked with the rating each opening needs to [email protected], or send them through the quote form; the reply comes back inside one working day with a written specification, the rating checked, and a budget range.

Ask for test evidence for the whole window, not for the glass alone. A BR class for a pane and an FB class for the window are different claims, and the handover should name both.

Questions about bullet resistant windows in London

Do bullet resistant windows in London look different from ordinary windows?

From the street, a well detailed window can look close to an ordinary one. The glass is thicker, the frame section is deeper, and the bead and gasket are heavier, but the sightlines can be kept neat where the survey allows it.

Can the existing frame be kept and only the glass changed?

Only where the existing frame has test evidence for the class needed, which is rare for an ordinary frame. In most London buildings the frame is replaced with a tested frame graded to match the glazing, because the rating applies to the window as a whole and an ungraded frame leaves the opening untested.

What rating fits a bank branch or a jeweller in London?

The threat assessment decides, and no single class fits every branch or shop. Cash rooms and displays often sit in the FB3 to FB4 range, while embassy and government rooms can sit higher, and the class is set opening by opening from the weapon types, the distance, and the time staff need to reach safety.

Planning bullet resistant windows for a London building? Post the drawings and the rating for each opening and we will reply within a working day.

Get a free quote

Ready to specify your project?

Free assessment, written specification and test evidence. Reply within one working day.