Areas we cover
Security doors and physical security in Bristol
Security doors and physical security in Bristol, UK. LPS 1175 doors, RF shielding and glazing protection for engineering, technology and university sites.
- ✓Third-party test evidence with every product
- ✓Written specification you can issue to tender
- ✓Supplied and installed in Bristol
Get a free quote in Bristol
Rating, written specification and budget range within one working day.
Confidential. No cost, no obligation.
Third-party tested
Evidence with every quote
UK manufactured
Made to your sizes
One accountable team
Specify, supply, install
Confidential handling
Details never shared
Supplied and installed in Bristol
What we supply in Bristol
Bristol’s security map stretches from aerospace plants to harbourside apartments, taking in engineering, creative and university sites. ArxBridge supplies and installs rated security doors, shielding and glazing protection across the city, working with architects, contractors and consultants.
- dB attenuation specifiedRF shielding over a frequency range
- LPS 1175 ratings SR2 to SR5Doorsets rated for forced entry
- EN 1522 FB2 to FB7Rated against handguns and rifles
- Fire classes EI 30 to EI 120Integrity and insulation rated
Engineering, technology and test facilities
Engineering and technology sites need protection for labs, test rigs and prototype stores. LPS 1175 security doors secure the rooms, while RF shielded rooms protect sensitive test environments from electromagnetic interference.
Shielding is specified by attenuation in dB over a frequency range, and it is verified after installation. Our testing and surveys service measures installed performance against the specification, so the room is proven, not assumed.
Where the threat picture includes deliberate attack on equipment, bullet resistant doors and glazing to EN 1522 and EN 1063 can be combined with the shielding in the same room.
Harbourside and creative quarters
The harbourside’s converted warehouses and new creative workspaces need security that suits brick and timber architecture. Rated doors in heritage styles, attack-rated glazing and discreet grilles protect without spoiling the character.
Ground-floor studios and galleries use retractable security grilles that vanish during opening hours. Service yards take security shutters and security gates.
Planning officers in conservation areas usually accept rated products that match the existing architecture. We supply the technical details the application needs.
Rating guide for Bristol sites
Use this as a starting guide. The threat assessment and the shielding specification set the final requirements for every room.
| Facility | Need | Typical rating | Product |
|---|---|---|---|
| Test laboratories | EM interference control | RF shielding, dB specified | Electromagnetic and RF shielding |
| Prototype stores | Forced entry | LPS 1175 SR3 | Security doors |
| High-risk offices | Ballistic threat | FB4 to FB6 | Bullet resistant windows |
| Creative workspaces | Overnight protection | Grilles and LPS 1270 | Retractable security grilles |
| University labs | Mixed needs | SR2 or SR3, fire rated | Fire and security doors |
| Data and comms rooms | Intrusion and shielding | LPS 1175 with RF | Data centres |
Test and research buildings often need the widest mix of ratings on one site. We schedule each room from the consultant’s specification, so shielding, fire and attack ratings are all covered.
Universities and research buildings
University estates combine historic colleges, science buildings and student housing. MRI shielded rooms need RF shielding, and RF shielding is different from magnetic shielding: many suites need both, verified after installation.
Secure meeting rooms for research partnerships use sound masking against eavesdropping, alongside LPS 1175 doors on the room itself. Education estates bring all of these needs together on one campus.
Shielding must be verified, not assumed. We test installed RF shielding and report attenuation against the specified frequency range, so the room’s performance is documented.
EMP protection for critical systems
Some Bristol technology sites need protection against electromagnetic pulse as well as everyday interference. EMP shielding goes beyond a standard RF room: power and signal entries must be filtered, or the pulse enters through the cables.
Testing and surveys verify the installed room against its specification. Where the risk assessment also calls for forced entry resistance, LPS 1175 security doors are built into the shielded envelope.
EMP protection is specified from a threat assessment, not from a catalogue. The assessment decides which rooms need it and what attenuation the shield must achieve across the frequency range.
Frequently asked questions
What does RF shielding protect against?
It blocks electromagnetic signals entering or leaving a room, protecting test equipment from interference and sensitive work from interception. Performance is specified in dB over a frequency range.
Do you install in university laboratories?
Yes. We supply and install across Bristol’s university estates, from teaching buildings to research laboratories.
Can a room be both shielded and attack rated?
Yes. RF shielding can be combined with LPS 1175 doorsets and ballistic glazing where the threat assessment calls for both.
What is sound masking?
It raises the background sound level in secure rooms so conversations cannot be overheard, protecting meeting rooms against eavesdropping.
Get a free quote
Ready to specify your project?
Free assessment, written specification and test evidence. Reply within one working day.